Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao

Surge arresters are applied to protect electrical apparatus against overvoltages. Many arresters have been damage before the expected operating lifetime of the main equipment they are protecting, usually 25-30 years. The paper presents laboratory and field tests that are being performed to fully inv...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile nagusia: Aquino, Claudio Vara (author)
Formatua: article
Argitaratua: 1993
Gaiak:
Sarrera elektronikoa:http://bibdigital.epn.edu.ec/handle/15000/9676
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
_version_ 1827332048226877440
author Aquino, Claudio Vara
author_facet Aquino, Claudio Vara
author_role author
collection Repositorio Escuela Politécnica Nacional
dc.creator.none.fl_str_mv Aquino, Claudio Vara
dc.date.none.fl_str_mv 1993-07
2007-10-31T13:40:41Z
2007-10-31T13:40:41Z
2010-09-07T17:53:01Z
2010-09-07T17:53:01Z
2011-03-10T17:34:22Z
2011-03-10T17:34:22Z
dc.identifier.none.fl_str_mv http://bibdigital.epn.edu.ec/handle/15000/9676
dc.language.none.fl_str_mv other
dc.rights.none.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Politécnica Nacional
instname:Escuela Politécnica Nacional
instacron:EPN
dc.subject.none.fl_str_mv PARARRAYOS
LIGHTNING ARRESTERS
dc.title.none.fl_str_mv Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Surge arresters are applied to protect electrical apparatus against overvoltages. Many arresters have been damage before the expected operating lifetime of the main equipment they are protecting, usually 25-30 years. The paper presents laboratory and field tests that are being performed to fully investigate the performance of conventional silicon carbide gapped arresters and the main causes of their failures. Diagnosis techniques for monitoring the conditions of surge arresters in service, to detect suspected units, are compared. Special attention is given to their field execution easiness and reliability.
eu_rights_str_mv openAccess
format article
id EPN_ff7a4bf4a30f61861e7545911fce70df
instacron_str EPN
institution EPN
instname_str Escuela Politécnica Nacional
language_invalid_str_mv other
network_acronym_str EPN
network_name_str Repositorio Escuela Politécnica Nacional
oai_identifier_str oai:bibdigital.epn.edu.ec:15000/9676
publishDate 1993
reponame_str Repositorio Escuela Politécnica Nacional
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Politécnica Nacional - Escuela Politécnica Nacional
repository_id_str 1553
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
spelling Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta TensaoAquino, Claudio VaraPARARRAYOSLIGHTNING ARRESTERSSurge arresters are applied to protect electrical apparatus against overvoltages. Many arresters have been damage before the expected operating lifetime of the main equipment they are protecting, usually 25-30 years. The paper presents laboratory and field tests that are being performed to fully investigate the performance of conventional silicon carbide gapped arresters and the main causes of their failures. Diagnosis techniques for monitoring the conditions of surge arresters in service, to detect suspected units, are compared. Special attention is given to their field execution easiness and reliability.2007-10-31T13:40:41Z2010-09-07T17:53:01Z2011-03-10T17:34:22Z2007-10-31T13:40:41Z2010-09-07T17:53:01Z2011-03-10T17:34:22Z1993-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://bibdigital.epn.edu.ec/handle/15000/9676otherhttps://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessreponame:Repositorio Escuela Politécnica Nacionalinstname:Escuela Politécnica Nacionalinstacron:EPN2023-05-01T18:06:04Zoai:bibdigital.epn.edu.ec:15000/9676Institucionalhttps://bibdigital.epn.edu.ec/Universidad públicahttps://www.epn.edu.ec/https://bibdigital.epn.edu.ec/oai.Ecuador...opendoar:15532023-05-01T18:06:04Repositorio Escuela Politécnica Nacional - Escuela Politécnica Nacionalfalse
spellingShingle Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
Aquino, Claudio Vara
PARARRAYOS
LIGHTNING ARRESTERS
status_str publishedVersion
title Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
title_full Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
title_fullStr Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
title_full_unstemmed Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
title_short Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
title_sort Técnicas de diagnóstico para a Identificacao de Pára-raios Convencionais (SiC) Defeituosos em Serviço nas Redes Elétricas de Alta Tensao
topic PARARRAYOS
LIGHTNING ARRESTERS
url http://bibdigital.epn.edu.ec/handle/15000/9676