Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.

This research study was based on the Design and Implementation of Drip Irrigation for pepper (Capsicum annuum L.) in the conventional area of the ESPAM – MFL, during the months of October 2011 to February 2012. Having done the calculations of Hydraulic Design by Blasius formulas for optimal manageme...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
מחבר ראשי: Intriago Vidal, Andrés Bolìvar (author)
מחברים אחרים: Zambrano, José Luis (author)
פורמט: bachelorThesis
שפה:spa
יצא לאור: 2012
נושאים:
גישה מקוונת:http://repositorio.espam.edu.ec/handle/42000/20
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1838775939960406016
author Intriago Vidal, Andrés Bolìvar
author2 Zambrano, José Luis
author2_role author
author_facet Intriago Vidal, Andrés Bolìvar
Zambrano, José Luis
author_role author
collection Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
dc.contributor.none.fl_str_mv Mendoza Cedeño, Leonardo
dc.creator.none.fl_str_mv Intriago Vidal, Andrés Bolìvar
Zambrano, José Luis
dc.date.none.fl_str_mv 2012-03
2015-06-17T18:29:12Z
2015-06-17T18:29:12Z
dc.format.none.fl_str_mv 112 p.
application/pdf
dc.identifier.none.fl_str_mv http://repositorio.espam.edu.ec/handle/42000/20
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Calceta: ESPAM
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
instname:Escuela Superior Politécnica Agropecuaria de Manabí
instacron:ESPAM
dc.subject.none.fl_str_mv El riego
Pimiento
El montaje
Diseño agronómico
dc.title.none.fl_str_mv Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description This research study was based on the Design and Implementation of Drip Irrigation for pepper (Capsicum annuum L.) in the conventional area of the ESPAM – MFL, during the months of October 2011 to February 2012. Having done the calculations of Hydraulic Design by Blasius formulas for optimal management and system design to meet Agricultural water requirements of the pepper crop was obtained the following results on the hydraulic flow required for emitter side or holder is 189 L/h and pressure of 14.524 psi required. The flow required for a lateral slide third was 11718 L/h and the commercial diameter of the pipe is 47.20 mm the appropriate pressure used in this module was 16.905 psi, the conduit is installed on 63 mm diameter was determined by calculations previously made, it will serve as driving to another peer with the same hydraulic characteristics. For the design was considered agronomic climatic conditions by averaging the crop water needs and readily available water supplies for growing pepper determining that the irrigation intervals are every 1.5 days and the run time is 51.40 minutes per day in their respective periods. Costs incurred in designing and implementing of the irrigation system is $ 2519.92, including labor and incidentals.
eu_rights_str_mv openAccess
format bachelorThesis
id ESPAM_14f2d4b4f334b3f812037eed2f2eb4cf
instacron_str ESPAM
institution ESPAM
instname_str Escuela Superior Politécnica Agropecuaria de Manabí
language spa
network_acronym_str ESPAM
network_name_str Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
oai_identifier_str oai:repositorio.espam.edu.ec:42000/20
publishDate 2012
publisher.none.fl_str_mv Calceta: ESPAM
reponame_str Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Superior Politécnica Agropecuaria de Manabí - Escuela Superior Politécnica Agropecuaria de Manabí
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.Intriago Vidal, Andrés BolìvarZambrano, José LuisEl riegoPimientoEl montajeDiseño agronómicoThis research study was based on the Design and Implementation of Drip Irrigation for pepper (Capsicum annuum L.) in the conventional area of the ESPAM – MFL, during the months of October 2011 to February 2012. Having done the calculations of Hydraulic Design by Blasius formulas for optimal management and system design to meet Agricultural water requirements of the pepper crop was obtained the following results on the hydraulic flow required for emitter side or holder is 189 L/h and pressure of 14.524 psi required. The flow required for a lateral slide third was 11718 L/h and the commercial diameter of the pipe is 47.20 mm the appropriate pressure used in this module was 16.905 psi, the conduit is installed on 63 mm diameter was determined by calculations previously made, it will serve as driving to another peer with the same hydraulic characteristics. For the design was considered agronomic climatic conditions by averaging the crop water needs and readily available water supplies for growing pepper determining that the irrigation intervals are every 1.5 days and the run time is 51.40 minutes per day in their respective periods. Costs incurred in designing and implementing of the irrigation system is $ 2519.92, including labor and incidentals.El presente estudio de investigación se basó en el diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, espam – mfl, durante los meses de octubre 2011 a febrero 2012. Una vez hecho los cálculos del diseño hidráulico mediante la fórmula de blasius para el óptimo manejo del sistema y del diseño agronómico para cumplir con los requerimientos hídricos del cultivo del pimiento se obtuvo los siguientes resultados; en la parte hidráulica, el caudal necesario para un lateral o porta goteros es de 189 l/h y la presión necesaria de 14.524 psi. El caudal necesario para una terciaria o porta laterales fue de 11718 l/h y el diámetro comercial de la tubería es 47.20 mm, la presión adecuada utilizada en éste módulo fue 16.905 psi, la tubería de conducción instalada es de 63 mm de diámetro que se determinó por cálculos previamente realizados, la misma que servirá como conducción a otro sistema de goteo de iguales características hidráulicas. Para el diseño agronómico se consideró las condiciones climáticas promediando las necesidades hídricas del cultivo y las reservas de agua fácilmente disponible para el cultivo de pimiento, determinando que los intervalos de riego son cada 1.5 días y el tiempo de riego es de 51.40 minutos diarios en sus respectivas períodos. Los costos incurridos en diseñar e implementar el sistema de riego es de $ 2519.92 usd, comprendida la mano de obra y el porcentaje de imprevistos.Calceta: ESPAMMendoza Cedeño, Leonardo2015-06-17T18:29:12Z2015-06-17T18:29:12Z2012-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis112 p.application/pdfhttp://repositorio.espam.edu.ec/handle/42000/20spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica Agropecuaria de Manabíinstname:Escuela Superior Politécnica Agropecuaria de Manabíinstacron:ESPAM2018-11-19T05:29:15Zoai:repositorio.espam.edu.ec:42000/20Institucionalhttps://repositorio.espam.edu.ec/Universidad públicahttp://www.espam.edu.ec/https://repositorio.espam.edu.ec/oai.Ecuador...opendoar:02025-07-27T05:14:02.260513Repositorio Escuela Superior Politécnica Agropecuaria de Manabí - Escuela Superior Politécnica Agropecuaria de Manabítrue
spellingShingle Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
Intriago Vidal, Andrés Bolìvar
El riego
Pimiento
El montaje
Diseño agronómico
status_str publishedVersion
title Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
title_full Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
title_fullStr Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
title_full_unstemmed Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
title_short Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
title_sort Diseño e implementación de un sistema de riego por goteo para pimiento (capsicum annuum l.) en el área convencional, ESPAM-MFL.
topic El riego
Pimiento
El montaje
Diseño agronómico
url http://repositorio.espam.edu.ec/handle/42000/20