Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte

Excess noise is a global problem with a high frequency in transportation terminals, where the maximum levels established by the respective regulations of the country where it originates are generally exceeded. The purpose of this work is to evaluate the sound pressure levels in the land terminal in...

Description complète

Enregistré dans:
Détails bibliographiques
Auteur principal: Burgos Cadena, Cristhian Leonardo (author)
Autres auteurs: Mieles Intriago, Diego Franshua (author)
Format: bachelorThesis
Langue:spa
Publié: 2023
Sujets:
Accès en ligne:http://repositorio.espam.edu.ec/handle/42000/2136
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1856532495846080512
author Burgos Cadena, Cristhian Leonardo
author2 Mieles Intriago, Diego Franshua
author2_role author
author_facet Burgos Cadena, Cristhian Leonardo
Mieles Intriago, Diego Franshua
author_role author
collection Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
dc.contributor.none.fl_str_mv Giler Molina, José Miguel
dc.creator.none.fl_str_mv Burgos Cadena, Cristhian Leonardo
Mieles Intriago, Diego Franshua
dc.date.none.fl_str_mv 2023-07-26T20:19:40Z
2023-07-26T20:19:40Z
2023-07
dc.format.none.fl_str_mv 51 p.
application/pdf
dc.identifier.none.fl_str_mv http://repositorio.espam.edu.ec/handle/42000/2136
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Calceta: ESPAM MFL
dc.rights.none.fl_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
instname:Escuela Superior Politécnica Agropecuaria de Manabí
instacron:ESPAM
dc.subject.none.fl_str_mv Ruido
Presión sonora
TULSMA
Terminal
Decibel
dc.title.none.fl_str_mv Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description Excess noise is a global problem with a high frequency in transportation terminals, where the maximum levels established by the respective regulations of the country where it originates are generally exceeded. The purpose of this work is to evaluate the sound pressure levels in the land terminal in Rocafuerte city, taking as a reference the provisions of the Unified Text of Environmental Legislation (TULSMA) for the evaluation and management of noise. The sound pressure level was evaluated at different points of the terminal through the application of five monitoring points located 50 meters apart; a noise map was drawn up and corrective and preventive measures were proposed. The sound pressure level was above the maximum limit established by the TULSMA (60 dB), with a range of 66 to 82 dB, being the point located in the center of the terminal the one that obtained the highest noise, in addition, the midday period obtained higher levels with 70.3 to 82.6 dB. The measures were mainly focused on reducing the noise generated in the environment, reducing the noise from the emission source, and making proposals to the authorities in charge of the terminal.
eu_rights_str_mv openAccess
format bachelorThesis
id ESPAM_b1f0eadb7062fc0a8ff7f074c84a39c6
instacron_str ESPAM
institution ESPAM
instname_str Escuela Superior Politécnica Agropecuaria de Manabí
language spa
network_acronym_str ESPAM
network_name_str Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
oai_identifier_str oai:null:42000/2136
publishDate 2023
publisher.none.fl_str_mv Calceta: ESPAM MFL
reponame_str Repositorio Escuela Superior Politécnica Agropecuaria de Manabí
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Superior Politécnica Agropecuaria de Manabí - Escuela Superior Politécnica Agropecuaria de Manabí
repository_id_str 0
rights_invalid_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
spelling Evaluación del nivel de presión sonora en el terminal terrestre de RocafuerteBurgos Cadena, Cristhian LeonardoMieles Intriago, Diego FranshuaRuidoPresión sonoraTULSMATerminalDecibelExcess noise is a global problem with a high frequency in transportation terminals, where the maximum levels established by the respective regulations of the country where it originates are generally exceeded. The purpose of this work is to evaluate the sound pressure levels in the land terminal in Rocafuerte city, taking as a reference the provisions of the Unified Text of Environmental Legislation (TULSMA) for the evaluation and management of noise. The sound pressure level was evaluated at different points of the terminal through the application of five monitoring points located 50 meters apart; a noise map was drawn up and corrective and preventive measures were proposed. The sound pressure level was above the maximum limit established by the TULSMA (60 dB), with a range of 66 to 82 dB, being the point located in the center of the terminal the one that obtained the highest noise, in addition, the midday period obtained higher levels with 70.3 to 82.6 dB. The measures were mainly focused on reducing the noise generated in the environment, reducing the noise from the emission source, and making proposals to the authorities in charge of the terminal.El exceso de ruido es un problema global con una alta frecuencia en las terminales de transporte, donde por lo general se exceden los niveles máximos establecidos por la normativa respectiva del país donde se origina. El presente trabajo tuvo la finalidad de evaluar los niveles de presión sonora en el terminal terrestre de la ciudad de Rocafuerte, tomando como referencia las disposiciones del Texto Unificado de Legislación Ambiental (TULSMA) para la evaluación y gestión del ruido. Se evaluó el nivel de presión sonora en diferentes puntos del terminal mediante la aplicación de 5 puntos de monitoreo ubicados con una separación de 50 metros; se realizó un mapa de ruido y se propusieron medidas correctivas y de prevención. El nivel de presión sonora estuvo por encima del límite máximo establecido por el TULSMA (60 dB), con un rango de 66 a 82 dB, siendo el punto ubicado en el centro del terminal el que obtuvo mayor ruido; además, el periodo del mediodía obtuvo mayores niveles con 70,3 a 82,6 dB. Las medidas fueron enfocadas principalmente en reducir el ruido generado en el ambiente, reducir el ruido desde la fuente de emisión, y realizar propuestas hacia las autoridades encargadas del terminal.Calceta: ESPAM MFLGiler Molina, José Miguel2023-07-26T20:19:40Z2023-07-26T20:19:40Z2023-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis51 p.application/pdfhttp://repositorio.espam.edu.ec/handle/42000/2136spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica Agropecuaria de Manabíinstname:Escuela Superior Politécnica Agropecuaria de Manabíinstacron:ESPAM2025-12-30T06:37:48Zoai:null:42000/2136Institucionalhttps://repositorio.espam.edu.ec/Universidad públicahttp://www.espam.edu.ec/https://repositorio.espam.edu.ec/oai.Ecuador...opendoar:02025-12-30T06:37:48Repositorio Escuela Superior Politécnica Agropecuaria de Manabí - Escuela Superior Politécnica Agropecuaria de Manabífalse
spellingShingle Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
Burgos Cadena, Cristhian Leonardo
Ruido
Presión sonora
TULSMA
Terminal
Decibel
status_str publishedVersion
title Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
title_full Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
title_fullStr Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
title_full_unstemmed Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
title_short Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
title_sort Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
topic Ruido
Presión sonora
TULSMA
Terminal
Decibel
url http://repositorio.espam.edu.ec/handle/42000/2136