Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte
Excess noise is a global problem with a high frequency in transportation terminals, where the maximum levels established by the respective regulations of the country where it originates are generally exceeded. The purpose of this work is to evaluate the sound pressure levels in the land terminal in...
Enregistré dans:
| Auteur principal: | |
|---|---|
| Autres auteurs: | |
| Format: | bachelorThesis |
| Langue: | spa |
| Publié: |
2023
|
| Sujets: | |
| Accès en ligne: | http://repositorio.espam.edu.ec/handle/42000/2136 |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1856532495846080512 |
|---|---|
| author | Burgos Cadena, Cristhian Leonardo |
| author2 | Mieles Intriago, Diego Franshua |
| author2_role | author |
| author_facet | Burgos Cadena, Cristhian Leonardo Mieles Intriago, Diego Franshua |
| author_role | author |
| collection | Repositorio Escuela Superior Politécnica Agropecuaria de Manabí |
| dc.contributor.none.fl_str_mv | Giler Molina, José Miguel |
| dc.creator.none.fl_str_mv | Burgos Cadena, Cristhian Leonardo Mieles Intriago, Diego Franshua |
| dc.date.none.fl_str_mv | 2023-07-26T20:19:40Z 2023-07-26T20:19:40Z 2023-07 |
| dc.format.none.fl_str_mv | 51 p. application/pdf |
| dc.identifier.none.fl_str_mv | http://repositorio.espam.edu.ec/handle/42000/2136 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Calceta: ESPAM MFL |
| dc.rights.none.fl_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Escuela Superior Politécnica Agropecuaria de Manabí instname:Escuela Superior Politécnica Agropecuaria de Manabí instacron:ESPAM |
| dc.subject.none.fl_str_mv | Ruido Presión sonora TULSMA Terminal Decibel |
| dc.title.none.fl_str_mv | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | Excess noise is a global problem with a high frequency in transportation terminals, where the maximum levels established by the respective regulations of the country where it originates are generally exceeded. The purpose of this work is to evaluate the sound pressure levels in the land terminal in Rocafuerte city, taking as a reference the provisions of the Unified Text of Environmental Legislation (TULSMA) for the evaluation and management of noise. The sound pressure level was evaluated at different points of the terminal through the application of five monitoring points located 50 meters apart; a noise map was drawn up and corrective and preventive measures were proposed. The sound pressure level was above the maximum limit established by the TULSMA (60 dB), with a range of 66 to 82 dB, being the point located in the center of the terminal the one that obtained the highest noise, in addition, the midday period obtained higher levels with 70.3 to 82.6 dB. The measures were mainly focused on reducing the noise generated in the environment, reducing the noise from the emission source, and making proposals to the authorities in charge of the terminal. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | ESPAM_b1f0eadb7062fc0a8ff7f074c84a39c6 |
| instacron_str | ESPAM |
| institution | ESPAM |
| instname_str | Escuela Superior Politécnica Agropecuaria de Manabí |
| language | spa |
| network_acronym_str | ESPAM |
| network_name_str | Repositorio Escuela Superior Politécnica Agropecuaria de Manabí |
| oai_identifier_str | oai:null:42000/2136 |
| publishDate | 2023 |
| publisher.none.fl_str_mv | Calceta: ESPAM MFL |
| reponame_str | Repositorio Escuela Superior Politécnica Agropecuaria de Manabí |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Escuela Superior Politécnica Agropecuaria de Manabí - Escuela Superior Politécnica Agropecuaria de Manabí |
| repository_id_str | 0 |
| rights_invalid_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ |
| spelling | Evaluación del nivel de presión sonora en el terminal terrestre de RocafuerteBurgos Cadena, Cristhian LeonardoMieles Intriago, Diego FranshuaRuidoPresión sonoraTULSMATerminalDecibelExcess noise is a global problem with a high frequency in transportation terminals, where the maximum levels established by the respective regulations of the country where it originates are generally exceeded. The purpose of this work is to evaluate the sound pressure levels in the land terminal in Rocafuerte city, taking as a reference the provisions of the Unified Text of Environmental Legislation (TULSMA) for the evaluation and management of noise. The sound pressure level was evaluated at different points of the terminal through the application of five monitoring points located 50 meters apart; a noise map was drawn up and corrective and preventive measures were proposed. The sound pressure level was above the maximum limit established by the TULSMA (60 dB), with a range of 66 to 82 dB, being the point located in the center of the terminal the one that obtained the highest noise, in addition, the midday period obtained higher levels with 70.3 to 82.6 dB. The measures were mainly focused on reducing the noise generated in the environment, reducing the noise from the emission source, and making proposals to the authorities in charge of the terminal.El exceso de ruido es un problema global con una alta frecuencia en las terminales de transporte, donde por lo general se exceden los niveles máximos establecidos por la normativa respectiva del país donde se origina. El presente trabajo tuvo la finalidad de evaluar los niveles de presión sonora en el terminal terrestre de la ciudad de Rocafuerte, tomando como referencia las disposiciones del Texto Unificado de Legislación Ambiental (TULSMA) para la evaluación y gestión del ruido. Se evaluó el nivel de presión sonora en diferentes puntos del terminal mediante la aplicación de 5 puntos de monitoreo ubicados con una separación de 50 metros; se realizó un mapa de ruido y se propusieron medidas correctivas y de prevención. El nivel de presión sonora estuvo por encima del límite máximo establecido por el TULSMA (60 dB), con un rango de 66 a 82 dB, siendo el punto ubicado en el centro del terminal el que obtuvo mayor ruido; además, el periodo del mediodía obtuvo mayores niveles con 70,3 a 82,6 dB. Las medidas fueron enfocadas principalmente en reducir el ruido generado en el ambiente, reducir el ruido desde la fuente de emisión, y realizar propuestas hacia las autoridades encargadas del terminal.Calceta: ESPAM MFLGiler Molina, José Miguel2023-07-26T20:19:40Z2023-07-26T20:19:40Z2023-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis51 p.application/pdfhttp://repositorio.espam.edu.ec/handle/42000/2136spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica Agropecuaria de Manabíinstname:Escuela Superior Politécnica Agropecuaria de Manabíinstacron:ESPAM2025-12-30T06:37:48Zoai:null:42000/2136Institucionalhttps://repositorio.espam.edu.ec/Universidad públicahttp://www.espam.edu.ec/https://repositorio.espam.edu.ec/oai.Ecuador...opendoar:02025-12-30T06:37:48Repositorio Escuela Superior Politécnica Agropecuaria de Manabí - Escuela Superior Politécnica Agropecuaria de Manabífalse |
| spellingShingle | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte Burgos Cadena, Cristhian Leonardo Ruido Presión sonora TULSMA Terminal Decibel |
| status_str | publishedVersion |
| title | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| title_full | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| title_fullStr | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| title_full_unstemmed | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| title_short | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| title_sort | Evaluación del nivel de presión sonora en el terminal terrestre de Rocafuerte |
| topic | Ruido Presión sonora TULSMA Terminal Decibel |
| url | http://repositorio.espam.edu.ec/handle/42000/2136 |