Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.

Energy production through wind power generation systems presents instability mainly due to wind variability the dynamic performance of the DC-Link is necessary for the proper operation of wind power plants using PMSG-based technologies, therefore, it is necessary to guarantee the efficient voltage c...

全面介绍

Saved in:
书目详细资料
主要作者: Molina Gordillo, Steven Xavier (author)
其他作者: Santo Chiluisa, Marco Antonio (author)
格式: article
语言:eng
出版: 2022
主题:
在线阅读:http://repositorio.espe.edu.ec/handle/21000/33562
标签: 添加标签
没有标签, 成为第一个标记此记录!
_version_ 1839981014585180160
author Molina Gordillo, Steven Xavier
author2 Santo Chiluisa, Marco Antonio
author2_role author
author_facet Molina Gordillo, Steven Xavier
Santo Chiluisa, Marco Antonio
author_role author
collection Repositorio Universidad de las Fuerzas Armadas
dc.contributor.none.fl_str_mv Llanos Proaño, Jacqueline del Rosario
dc.creator.none.fl_str_mv Molina Gordillo, Steven Xavier
Santo Chiluisa, Marco Antonio
dc.date.none.fl_str_mv 2022-10-11T15:36:52Z
2022-10-11T15:36:52Z
2022-08-15
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.identifier.none.fl_str_mv Molina Gordillo, Steven Xavier. Santo Chiluisa, Marco Antonio (2022). Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid. Carrera de Ingeniería Electrónica e Instrumentación. Departamento de Eléctrica y Electrónica. Universidad de las Fuerzas Armadas ESPE. Extensión Latacunga.
ENI-0490
http://repositorio.espe.edu.ec/handle/21000/33562
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Universidad de las Fuerzas Armadas ESPE. Extensión Latacunga. Carrera de Ingeniería en Electrónica e Instrumentación.
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad de las Fuerzas Armadas
instname:Universidad de las Fuerzas Armadas
instacron:ESPE
dc.subject.none.fl_str_mv SISTEMA EÓLICO
AEROGENERADORES
dc.title.none.fl_str_mv Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Energy production through wind power generation systems presents instability mainly due to wind variability the dynamic performance of the DC-Link is necessary for the proper operation of wind power plants using PMSG-based technologies, therefore, it is necessary to guarantee the efficient voltage control in the DC-Link in a back to back topology of the converters used for the energy conversion. This research compares the effect of implementing DC-Link voltage control on the Grid Side Converter versus DC-Link voltage control on the Machine Side Converter. The simulated system consists of a wind turbine coupled to the Permanent Magnet Synchronous Generator, Power Electronic Converters and the grid. Internal current controllers and external DC-link voltage control are designed for each case. The performance of the system against wind speed changes and voltage faults in the grid is evaluated and compared.
eu_rights_str_mv openAccess
format article
id ESPE_63e951034d48982e0f46a3681e6f7575
identifier_str_mv Molina Gordillo, Steven Xavier. Santo Chiluisa, Marco Antonio (2022). Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid. Carrera de Ingeniería Electrónica e Instrumentación. Departamento de Eléctrica y Electrónica. Universidad de las Fuerzas Armadas ESPE. Extensión Latacunga.
ENI-0490
instacron_str ESPE
institution ESPE
instname_str Universidad de las Fuerzas Armadas
language eng
network_acronym_str ESPE
network_name_str Repositorio Universidad de las Fuerzas Armadas
oai_identifier_str oai:repositorio.espe.edu.ec:21000/33562
publishDate 2022
publisher.none.fl_str_mv Universidad de las Fuerzas Armadas ESPE. Extensión Latacunga. Carrera de Ingeniería en Electrónica e Instrumentación.
reponame_str Repositorio Universidad de las Fuerzas Armadas
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad de las Fuerzas Armadas - Universidad de las Fuerzas Armadas
repository_id_str 2042
spelling Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.Molina Gordillo, Steven XavierSanto Chiluisa, Marco AntonioSISTEMA EÓLICOAEROGENERADORESEnergy production through wind power generation systems presents instability mainly due to wind variability the dynamic performance of the DC-Link is necessary for the proper operation of wind power plants using PMSG-based technologies, therefore, it is necessary to guarantee the efficient voltage control in the DC-Link in a back to back topology of the converters used for the energy conversion. This research compares the effect of implementing DC-Link voltage control on the Grid Side Converter versus DC-Link voltage control on the Machine Side Converter. The simulated system consists of a wind turbine coupled to the Permanent Magnet Synchronous Generator, Power Electronic Converters and the grid. Internal current controllers and external DC-link voltage control are designed for each case. The performance of the system against wind speed changes and voltage faults in the grid is evaluated and compared.ESPE-LUniversidad de las Fuerzas Armadas ESPE. Extensión Latacunga. Carrera de Ingeniería en Electrónica e Instrumentación.Llanos Proaño, Jacqueline del Rosario2022-10-11T15:36:52Z2022-10-11T15:36:52Z2022-08-15info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/pdfMolina Gordillo, Steven Xavier. Santo Chiluisa, Marco Antonio (2022). Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid. Carrera de Ingeniería Electrónica e Instrumentación. Departamento de Eléctrica y Electrónica. Universidad de las Fuerzas Armadas ESPE. Extensión Latacunga.ENI-0490http://repositorio.espe.edu.ec/handle/21000/33562enginfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad de las Fuerzas Armadasinstname:Universidad de las Fuerzas Armadasinstacron:ESPE2024-07-27T09:50:08Zoai:repositorio.espe.edu.ec:21000/33562Institucionalhttps://repositorio.espe.edu.ec/Universidad públicahttps://www.espe.edu.ec/https://repositorio.espe.edu.ec/oai.Ecuador...opendoar:20422024-07-27T09:50:08Repositorio Universidad de las Fuerzas Armadas - Universidad de las Fuerzas Armadasfalse
spellingShingle Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
Molina Gordillo, Steven Xavier
SISTEMA EÓLICO
AEROGENERADORES
status_str publishedVersion
title Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
title_full Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
title_fullStr Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
title_full_unstemmed Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
title_short Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
title_sort Comparison of DC-Link Voltage Control Architectures on Grid-Side and Machine Side for Permanent Magnet Synchronous Generator Connected to the Grid.
topic SISTEMA EÓLICO
AEROGENERADORES
url http://repositorio.espe.edu.ec/handle/21000/33562