Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon

The campus " Ing. Gustavo Galindo Velasco " is located in the Santa Elena Province and comprehends 1.200Km2. The studied and analyzed areas were: Estacion Casa Bomba, Estación Gas Natural Vehicular (GNV) and the Electrical Substation. This last one was constructed by the English standard e...

Full description

Saved in:
Bibliographic Details
Main Author: Bravo, Martha (author)
Other Authors: Rosero, Galo (author), Uttermann, Andrea (author), Gallo., Juan (author)
Format: article
Language:spa
Published: 2009
Subjects:
Online Access:http://www.dspace.espol.edu.ec/handle/123456789/7646
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1858337435560181760
author Bravo, Martha
author2 Rosero, Galo
Uttermann, Andrea
Gallo., Juan
author2_role author
author
author
author_facet Bravo, Martha
Rosero, Galo
Uttermann, Andrea
Gallo., Juan
author_role author
collection Repositorio Escuela Superior Politécnica del Litoral
dc.creator.none.fl_str_mv Bravo, Martha
Rosero, Galo
Uttermann, Andrea
Gallo., Juan
dc.date.none.fl_str_mv 2009-10-07
2009-10-07
2009-10-07
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://www.dspace.espol.edu.ec/handle/123456789/7646
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Superior Politécnica del Litoral
instname:Escuela Superior Politécnica del Litoral
instacron:ESPOL
dc.subject.none.fl_str_mv ANÁLISIS DE RIESGOS ELÉCTRICOS
CÓDIGO ELÉCTRICO NACIONAL (NEC)
SEGURIDAD INDUSTRIAL
dc.title.none.fl_str_mv Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description The campus " Ing. Gustavo Galindo Velasco " is located in the Santa Elena Province and comprehends 1.200Km2. The studied and analyzed areas were: Estacion Casa Bomba, Estación Gas Natural Vehicular (GNV) and the Electrical Substation. This last one was constructed by the English standard electrical norms, which were not established inside the Ecuadorian Standards and that therefore raise difficulties for the reinstatement of devices when these finish its useful life or need corrective and preventive maintenance. The stations Casa Bomba and Gas Natural Vehicular, have been modified recently, they are based on the procedure NFPA 70 and NEC. In each of them there has been applied three analysis of Risks methods: Checklist, What If? Method and The Failure Modes and Effects Analysis (FMEA). This analysis allowed us to check the level of risk that is present in each of the stations studied for a better control, functioning, maintenance and the electrical device protection. We think that these studies are of a lot of interest not only for the security of the personal from the company, but also for the electrical device maintenance , optimizing its useful life and a constant improvement in its processes
eu_rights_str_mv openAccess
format article
id ESPOL_1237fc8fe4bab76a52d60791f96cebea
instacron_str ESPOL
institution ESPOL
instname_str Escuela Superior Politécnica del Litoral
language spa
network_acronym_str ESPOL
network_name_str Repositorio Escuela Superior Politécnica del Litoral
oai_identifier_str oai:www.dspace.espol.edu.ec:123456789/7646
publishDate 2009
reponame_str Repositorio Escuela Superior Politécnica del Litoral
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoral
repository_id_str 1479
spelling Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - anconBravo, MarthaRosero, GaloUttermann, AndreaGallo., JuanANÁLISIS DE RIESGOS ELÉCTRICOSCÓDIGO ELÉCTRICO NACIONAL (NEC)SEGURIDAD INDUSTRIALThe campus " Ing. Gustavo Galindo Velasco " is located in the Santa Elena Province and comprehends 1.200Km2. The studied and analyzed areas were: Estacion Casa Bomba, Estación Gas Natural Vehicular (GNV) and the Electrical Substation. This last one was constructed by the English standard electrical norms, which were not established inside the Ecuadorian Standards and that therefore raise difficulties for the reinstatement of devices when these finish its useful life or need corrective and preventive maintenance. The stations Casa Bomba and Gas Natural Vehicular, have been modified recently, they are based on the procedure NFPA 70 and NEC. In each of them there has been applied three analysis of Risks methods: Checklist, What If? Method and The Failure Modes and Effects Analysis (FMEA). This analysis allowed us to check the level of risk that is present in each of the stations studied for a better control, functioning, maintenance and the electrical device protection. We think that these studies are of a lot of interest not only for the security of the personal from the company, but also for the electrical device maintenance , optimizing its useful life and a constant improvement in its processes2009-10-072009-10-072009-10-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://www.dspace.espol.edu.ec/handle/123456789/7646spainfo:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica del Litoralinstname:Escuela Superior Politécnica del Litoralinstacron:ESPOL2018-04-04T13:10:10Zoai:www.dspace.espol.edu.ec:123456789/7646Institucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oaiEcuador...opendoar:14792018-04-04T13:10:10falseInstitucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oai.Ecuador...opendoar:14792018-04-04T13:10:10Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoralfalse
spellingShingle Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
Bravo, Martha
ANÁLISIS DE RIESGOS ELÉCTRICOS
CÓDIGO ELÉCTRICO NACIONAL (NEC)
SEGURIDAD INDUSTRIAL
status_str publishedVersion
title Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
title_full Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
title_fullStr Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
title_full_unstemmed Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
title_short Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
title_sort Estudio del grado de riesgos y determinación de radio de peligro de áreas clasificadas peligrosas de instalaciones de equipos eléctricos en el campus petrolero ing. Gustavo Galindo Velasco - ancon
topic ANÁLISIS DE RIESGOS ELÉCTRICOS
CÓDIGO ELÉCTRICO NACIONAL (NEC)
SEGURIDAD INDUSTRIAL
url http://www.dspace.espol.edu.ec/handle/123456789/7646