Comprobación experimental de las cargas de pandeo de planchas con refuerzos

Due to the limited experience in the ecuadorean scope on estimation of critical loads of structures formed by plates with reinforcements, this project sought to revise formulations to evaluate the mentioned parameter, and compare it with experimental results. The classic reference [7], describes fou...

Повний опис

Збережено в:
Бібліографічні деталі
Автор: Rodríguez Lamchang, José María (author)
Формат: article
Мова:spa
Опубліковано: 2009
Предмети:
Онлайн доступ:http://www.dspace.espol.edu.ec/handle/123456789/6866
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
_version_ 1858337399406329856
author Rodríguez Lamchang, José María
author_facet Rodríguez Lamchang, José María
author_role author
collection Repositorio Escuela Superior Politécnica del Litoral
dc.creator.none.fl_str_mv Rodríguez Lamchang, José María
dc.date.none.fl_str_mv 2009-08-19
2009-08-19
2009-08-19
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://www.dspace.espol.edu.ec/handle/123456789/6866
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Superior Politécnica del Litoral
instname:Escuela Superior Politécnica del Litoral
instacron:ESPOL
dc.subject.none.fl_str_mv PANDEO
dc.title.none.fl_str_mv Comprobación experimental de las cargas de pandeo de planchas con refuerzos
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description Due to the limited experience in the ecuadorean scope on estimation of critical loads of structures formed by plates with reinforcements, this project sought to revise formulations to evaluate the mentioned parameter, and compare it with experimental results. The classic reference [7], describes four typical buckling modes for such structures: plate between 2 reinforcements, Flexural bending of stiffeners, torsion of stiffeners, and Total deflection of the panel. Formulations were implemented for each buckling mode. The reviewed formulae for estimating critical load for buckling of reinforced panels were implemented, and after varying the geometric parameters were set four panels, each of whom had at least the effort of one of the critical modes of buckling and described. Then, using stainless steel plate 1.5 mm thick, were built two specimens of each type of panel, with a maximum length of 1.20 m, considering the available equipment. Before developing the test, thickness and the resulting pre-deformation were measured. Thickness had little variation but pre-deformations were high, in the order of the thickness of the plate The experimental tests were conducted in the Universal Testing Machine of FIMCP, and determined the maximum force that bore the specimen. On the buckling of the plate between stiffeners, the experimental results are larger than the analytic, because the edges of the plate are welded to the reinforcements, while the analytical model considered simply supported. On the Flexural Buckling of longitudinal reinforcement, the theoretical results are higher than experimental ones, because of local failure between flange and web of the reinforcements, the distance between welds. In the torsional buckling, the plate twisted instead of the stiffeners, because side edges were not stiffen enough, and this substantially reduced the experimental effort critical. In total buckling of the panel, the longitudinal reinforcements flexes in parallel, since the edge stiffeners were not enough, resulting in a substantial difference between the results.
eu_rights_str_mv openAccess
format article
id ESPOL_5fb76a1a0e5f83da2ea8ede79443b3b6
instacron_str ESPOL
institution ESPOL
instname_str Escuela Superior Politécnica del Litoral
language spa
network_acronym_str ESPOL
network_name_str Repositorio Escuela Superior Politécnica del Litoral
oai_identifier_str oai:www.dspace.espol.edu.ec:123456789/6866
publishDate 2009
reponame_str Repositorio Escuela Superior Politécnica del Litoral
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoral
repository_id_str 1479
spelling Comprobación experimental de las cargas de pandeo de planchas con refuerzosRodríguez Lamchang, José MaríaPANDEODue to the limited experience in the ecuadorean scope on estimation of critical loads of structures formed by plates with reinforcements, this project sought to revise formulations to evaluate the mentioned parameter, and compare it with experimental results. The classic reference [7], describes four typical buckling modes for such structures: plate between 2 reinforcements, Flexural bending of stiffeners, torsion of stiffeners, and Total deflection of the panel. Formulations were implemented for each buckling mode. The reviewed formulae for estimating critical load for buckling of reinforced panels were implemented, and after varying the geometric parameters were set four panels, each of whom had at least the effort of one of the critical modes of buckling and described. Then, using stainless steel plate 1.5 mm thick, were built two specimens of each type of panel, with a maximum length of 1.20 m, considering the available equipment. Before developing the test, thickness and the resulting pre-deformation were measured. Thickness had little variation but pre-deformations were high, in the order of the thickness of the plate The experimental tests were conducted in the Universal Testing Machine of FIMCP, and determined the maximum force that bore the specimen. On the buckling of the plate between stiffeners, the experimental results are larger than the analytic, because the edges of the plate are welded to the reinforcements, while the analytical model considered simply supported. On the Flexural Buckling of longitudinal reinforcement, the theoretical results are higher than experimental ones, because of local failure between flange and web of the reinforcements, the distance between welds. In the torsional buckling, the plate twisted instead of the stiffeners, because side edges were not stiffen enough, and this substantially reduced the experimental effort critical. In total buckling of the panel, the longitudinal reinforcements flexes in parallel, since the edge stiffeners were not enough, resulting in a substantial difference between the results.2009-08-192009-08-192009-08-19info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://www.dspace.espol.edu.ec/handle/123456789/6866spainfo:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica del Litoralinstname:Escuela Superior Politécnica del Litoralinstacron:ESPOL2018-04-04T17:24:57Zoai:www.dspace.espol.edu.ec:123456789/6866Institucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oaiEcuador...opendoar:14792018-04-04T17:24:57falseInstitucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oai.Ecuador...opendoar:14792018-04-04T17:24:57Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoralfalse
spellingShingle Comprobación experimental de las cargas de pandeo de planchas con refuerzos
Rodríguez Lamchang, José María
PANDEO
status_str publishedVersion
title Comprobación experimental de las cargas de pandeo de planchas con refuerzos
title_full Comprobación experimental de las cargas de pandeo de planchas con refuerzos
title_fullStr Comprobación experimental de las cargas de pandeo de planchas con refuerzos
title_full_unstemmed Comprobación experimental de las cargas de pandeo de planchas con refuerzos
title_short Comprobación experimental de las cargas de pandeo de planchas con refuerzos
title_sort Comprobación experimental de las cargas de pandeo de planchas con refuerzos
topic PANDEO
url http://www.dspace.espol.edu.ec/handle/123456789/6866