Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales

The purpose of this project is the design and construction of a simulator that generates signals similar to those produced by the heart; these are captured and registered by the electrocardiograph. This project use the PIC16F886, a mid-range microcontroller, programmed in C language using the compil...

Description complète

Enregistré dans:
Détails bibliographiques
Auteur principal: Yapur, Miguel (author)
Autres auteurs: Argüello Altamirano, Sidney Jair (author), Márquez Velasteguí, Javier Nahim (author)
Format: article
Langue:spa
Publié: 2010
Sujets:
Accès en ligne:http://www.dspace.espol.edu.ec/handle/123456789/13495
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1858337261216595968
author Yapur, Miguel
author2 Argüello Altamirano, Sidney Jair
Márquez Velasteguí, Javier Nahim
author2_role author
author
author_facet Yapur, Miguel
Argüello Altamirano, Sidney Jair
Márquez Velasteguí, Javier Nahim
author_role author
collection Repositorio Escuela Superior Politécnica del Litoral
dc.creator.none.fl_str_mv Yapur, Miguel
Argüello Altamirano, Sidney Jair
Márquez Velasteguí, Javier Nahim
dc.date.none.fl_str_mv 2010-11-09
2010-11-09
2010-11-09
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://www.dspace.espol.edu.ec/handle/123456789/13495
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Superior Politécnica del Litoral
instname:Escuela Superior Politécnica del Litoral
instacron:ESPOL
dc.subject.none.fl_str_mv SIMULADOR
ELECTROCARDIÓGRAFO
ELECTROCARDIOGRAFÍA,
ELECTROCARDIOGRAMA
CARDIACO
SEÑALES DE PACIENTE.
dc.title.none.fl_str_mv Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description The purpose of this project is the design and construction of a simulator that generates signals similar to those produced by the heart; these are captured and registered by the electrocardiograph. This project use the PIC16F886, a mid-range microcontroller, programmed in C language using the compiler PICC of CCS enterprises. The circuit, besides simulating a normal cardiac signal, can also generate pathologies such as arrhythmia, tachycardia and bradycardia;, also can vary manually the increase or decrease of the heart rate in steps of 10 beats per minute(bpm). The number of beats per minute generated by the device, can be seen through 3 7-segment displays. This project was conceived by the need of designing a device that can be user-friendly and accessible; so in the present work a cheap circuit is implemented, avoiding the waste of resources and using more efficient designing techniques
eu_rights_str_mv openAccess
format article
id ESPOL_e4ccf3c9bdb16067630b7a64447f054d
instacron_str ESPOL
institution ESPOL
instname_str Escuela Superior Politécnica del Litoral
language spa
network_acronym_str ESPOL
network_name_str Repositorio Escuela Superior Politécnica del Litoral
oai_identifier_str oai:www.dspace.espol.edu.ec:123456789/13495
publishDate 2010
reponame_str Repositorio Escuela Superior Politécnica del Litoral
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoral
repository_id_str 1479
spelling Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitalesYapur, MiguelArgüello Altamirano, Sidney JairMárquez Velasteguí, Javier NahimSIMULADORELECTROCARDIÓGRAFOELECTROCARDIOGRAFÍA,ELECTROCARDIOGRAMACARDIACOSEÑALES DE PACIENTE.The purpose of this project is the design and construction of a simulator that generates signals similar to those produced by the heart; these are captured and registered by the electrocardiograph. This project use the PIC16F886, a mid-range microcontroller, programmed in C language using the compiler PICC of CCS enterprises. The circuit, besides simulating a normal cardiac signal, can also generate pathologies such as arrhythmia, tachycardia and bradycardia;, also can vary manually the increase or decrease of the heart rate in steps of 10 beats per minute(bpm). The number of beats per minute generated by the device, can be seen through 3 7-segment displays. This project was conceived by the need of designing a device that can be user-friendly and accessible; so in the present work a cheap circuit is implemented, avoiding the waste of resources and using more efficient designing techniques2010-11-092010-11-092010-11-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://www.dspace.espol.edu.ec/handle/123456789/13495spainfo:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica del Litoralinstname:Escuela Superior Politécnica del Litoralinstacron:ESPOL2018-04-04T18:05:44Zoai:www.dspace.espol.edu.ec:123456789/13495Institucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oaiEcuador...opendoar:14792018-04-04T18:05:44falseInstitucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oai.Ecuador...opendoar:14792018-04-04T18:05:44Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoralfalse
spellingShingle Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
Yapur, Miguel
SIMULADOR
ELECTROCARDIÓGRAFO
ELECTROCARDIOGRAFÍA,
ELECTROCARDIOGRAMA
CARDIACO
SEÑALES DE PACIENTE.
status_str publishedVersion
title Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
title_full Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
title_fullStr Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
title_full_unstemmed Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
title_short Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
title_sort Análisis, diseño y construcción de un simulador de señales de paciente para ser usado en electrocardiografía, utilizando comandos digitales
topic SIMULADOR
ELECTROCARDIÓGRAFO
ELECTROCARDIOGRAFÍA,
ELECTROCARDIOGRAMA
CARDIACO
SEÑALES DE PACIENTE.
url http://www.dspace.espol.edu.ec/handle/123456789/13495