Interfaz de receptor de bucle de 4-20ma en aplicación con dspic

This project was implemented with the aim of showing the benefits of using dsPIC applications in a long distance communication and develop a physical and functional software with LabVIEW. In this case we use the dsPIC to control the temperature required for the production of enzymes in the process o...

Olles dieđut

Furkejuvvon:
Bibliográfalaš dieđut
Váldodahkki: Valdivieso A., Carlos (author)
Eará dahkkit: Pazmiño R, Israel (author), Torres, Andres (author)
Materiálatiipa: article
Giella:spa
Almmustuhtton: 2009
Fáttát:
Liŋkkat:http://www.dspace.espol.edu.ec/handle/123456789/4864
Fáddágilkorat: Lasit fáddágilkoriid
Eai fáddágilkorat, Lasit vuosttaš fáddágilkora!
_version_ 1858337205416624128
author Valdivieso A., Carlos
author2 Pazmiño R, Israel
Torres, Andres
author2_role author
author
author_facet Valdivieso A., Carlos
Pazmiño R, Israel
Torres, Andres
author_role author
collection Repositorio Escuela Superior Politécnica del Litoral
dc.creator.none.fl_str_mv Valdivieso A., Carlos
Pazmiño R, Israel
Torres, Andres
dc.date.none.fl_str_mv 2009-04-22
2009-04-22
2009-04-22
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://www.dspace.espol.edu.ec/handle/123456789/4864
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Escuela Superior Politécnica del Litoral
instname:Escuela Superior Politécnica del Litoral
instacron:ESPOL
dc.subject.none.fl_str_mv DSPIC
LABVIEW
VISA
DSC
BUCLE
UART
dc.title.none.fl_str_mv Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
description This project was implemented with the aim of showing the benefits of using dsPIC applications in a long distance communication and develop a physical and functional software with LabVIEW. In this case we use the dsPIC to control the temperature required for the production of enzymes in the process of mashing malt. The loop receiver receives the signal from a temperature sensor in the form of voltage, which is conditioned and amplified before being transmitted as current over a long distance, in order to avoid interference from parasitic signals. The current receiver has an output of 0-5 VDC conditioned that connects to an analog input dsPIC30F4011 microcontroller to read the sensor data. This project will use LabVIEW to monitor the sensor signal through the VISA port driver and the dsPIC UART module. In addition the MAX232 integrated circuit is responsible for converting TTL signals to RS232 level signals that the computer reads.
eu_rights_str_mv openAccess
format article
id ESPOL_fa0b5465c1c628a0acc49446bc970cb2
instacron_str ESPOL
institution ESPOL
instname_str Escuela Superior Politécnica del Litoral
language spa
network_acronym_str ESPOL
network_name_str Repositorio Escuela Superior Politécnica del Litoral
oai_identifier_str oai:www.dspace.espol.edu.ec:123456789/4864
publishDate 2009
reponame_str Repositorio Escuela Superior Politécnica del Litoral
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoral
repository_id_str 1479
spelling Interfaz de receptor de bucle de 4-20ma en aplicación con dspicValdivieso A., CarlosPazmiño R, IsraelTorres, AndresDSPICLABVIEWVISADSCBUCLEUARTThis project was implemented with the aim of showing the benefits of using dsPIC applications in a long distance communication and develop a physical and functional software with LabVIEW. In this case we use the dsPIC to control the temperature required for the production of enzymes in the process of mashing malt. The loop receiver receives the signal from a temperature sensor in the form of voltage, which is conditioned and amplified before being transmitted as current over a long distance, in order to avoid interference from parasitic signals. The current receiver has an output of 0-5 VDC conditioned that connects to an analog input dsPIC30F4011 microcontroller to read the sensor data. This project will use LabVIEW to monitor the sensor signal through the VISA port driver and the dsPIC UART module. In addition the MAX232 integrated circuit is responsible for converting TTL signals to RS232 level signals that the computer reads.2009-04-222009-04-222009-04-22info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://www.dspace.espol.edu.ec/handle/123456789/4864spainfo:eu-repo/semantics/openAccessreponame:Repositorio Escuela Superior Politécnica del Litoralinstname:Escuela Superior Politécnica del Litoralinstacron:ESPOL2018-04-04T16:57:53Zoai:www.dspace.espol.edu.ec:123456789/4864Institucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oaiEcuador...opendoar:14792018-04-04T16:57:53falseInstitucionalhttps://www.dspace.espol.edu.ec/Universidad públicahttps://www.espol.edu.ec/.https://www.dspace.espol.edu.ec/oai.Ecuador...opendoar:14792018-04-04T16:57:53Repositorio Escuela Superior Politécnica del Litoral - Escuela Superior Politécnica del Litoralfalse
spellingShingle Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
Valdivieso A., Carlos
DSPIC
LABVIEW
VISA
DSC
BUCLE
UART
status_str publishedVersion
title Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
title_full Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
title_fullStr Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
title_full_unstemmed Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
title_short Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
title_sort Interfaz de receptor de bucle de 4-20ma en aplicación con dspic
topic DSPIC
LABVIEW
VISA
DSC
BUCLE
UART
url http://www.dspace.espol.edu.ec/handle/123456789/4864