Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students
AbstractIntroduction. The Pan American Health Organization ponders the importance of protection and safety against radiation and radiological emergencies, considering benefits and risks for the uses of radiation in industrial, medical and research applications. The use of radiation also has potentia...
Gorde:
| Egile nagusia: | |
|---|---|
| Beste egile batzuk: | , |
| Formatua: | article |
| Hizkuntza: | spa |
| Argitaratua: |
2021
|
| Gaiak: | |
| Sarrera elektronikoa: | https://revistadigital.uce.edu.ec/index.php/CIENCIAS_MEDICAS/article/view/3100 |
| Etiketak: |
Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
|
| _version_ | 1859105413994119168 |
|---|---|
| author | Barros-Astudillo , Teodoro |
| author2 | Olmedo-Raza , Norman Hidalgo-Gualán , Elida |
| author2_role | author author |
| author_facet | Barros-Astudillo , Teodoro Olmedo-Raza , Norman Hidalgo-Gualán , Elida |
| author_role | author |
| collection | Revista Ciencias Médicas |
| dc.creator.none.fl_str_mv | Barros-Astudillo , Teodoro Olmedo-Raza , Norman Hidalgo-Gualán , Elida |
| dc.date.none.fl_str_mv | 2021-01-01 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | https://revistadigital.uce.edu.ec/index.php/CIENCIAS_MEDICAS/article/view/3100 10.29166/rfcmq.v46i2.3100 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Quito: Universidad Central del Ecuador |
| dc.relation.none.fl_str_mv | https://revistadigital.uce.edu.ec/index.php/CIENCIAS_MEDICAS/article/view/3100/6619 |
| dc.rights.none.fl_str_mv | Derechos de autor 2021 TEODORO JOSE MARIA BARROS ASTUDILLO http://creativecommons.org/licenses/by-nc-nd/4.0 info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | Revista de la Facultad de Ciencias Médicas (Quito); Vol. 46 No. 2 (2021): Revista de la Facultad de Ciencias Médicas (Quito); 21 - 30 Revista de la Facultad de Ciencias Médicas (Quito); Vol. 46 Núm. 2 (2021): Revista de la Facultad de Ciencias Médicas (Quito); 21 - 30 2737-6141 2588-0691 reponame:Revista Ciencias Médicas instname:Universidad Central del Ecuador instacron:UCE |
| dc.subject.none.fl_str_mv | dosímetro protección radiológica radiología estudiante radiation dosimeters radiation protection radiology student |
| dc.title.none.fl_str_mv | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students Nivel de cumplimiento del uso del dosímetro como norma de protección radiológica de estudiantes de radiología |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
| description | AbstractIntroduction. The Pan American Health Organization ponders the importance of protection and safety against radiation and radiological emergencies, considering benefits and risks for the uses of radiation in industrial, medical and research applications. The use of radiation also has potential risks to the health of patients, workers (including health personnel), the public, and the environment. The Central University of Ecuador, through the Faculty of Medical Sciences, has the Radiology Career, which trains professionals in this area, with competencies for diagnostic studies, promotion, prevention and research for the benefit of people in a situation of illness; In this context, undergraduate students who carry out pre-professional training practices in health care units, and who are continuously exposed to risks due to ionizing radiation, are enrolled. Objective. Determine the level of compliance with the use of the dosimeter as a radiation protection standard in imaging. Material and methods. The study is descriptive, observational, cross-sectional and analytical. The sample is 58 undergraduate students (seventh and eighth semesters) randomly selected with a 95% confidence level, in the year 2019. Documentary analysis and survey (students and Heads of Radiology Service) were applied. The last three results of the dosimetry tests were analyzed. The reliability statistic of the instrument with Cronbach's Alpha is high (0.833). The data was processed through EXCEL and PSPP. Statistical analyzes were descriptive and a contingency table with Pearson's Chi2 test of independence. Results. The students, men and women, do not regularly use the dosimeter, in the three measurements. By sex, there is a significant difference according to Chi2, in the first measurement and second measurement (p<0.05). In the third measurement, there are no significant differences, but the two groups also do not regularly use the dosimeter. Limitation: The studied sample does not correspond to all the students of the radiology career, prioritizing the last years of training. Conclusions. There is non-compliance in the use of the dosimeter as a radiation protection standard, which increases the chances of health risks for students who carry out pre-professional training practices. |
| eu_rights_str_mv | openAccess |
| format | article |
| id | REVCMED_a9c77e34a41d192db53ebdd52d6adbfb |
| identifier_str_mv | 10.29166/rfcmq.v46i2.3100 |
| instacron_str | UCE |
| institution | UCE |
| instname_str | Universidad Central del Ecuador |
| language | spa |
| network_acronym_str | REVCMED |
| network_name_str | Revista Ciencias Médicas |
| oai_identifier_str | oai:revistadigital.uce.edu.ec:article/3100 |
| publishDate | 2021 |
| publisher.none.fl_str_mv | Quito: Universidad Central del Ecuador |
| reponame_str | Revista Ciencias Médicas |
| repository.mail.fl_str_mv | * |
| repository.name.fl_str_mv | Revista Ciencias Médicas - Universidad Central del Ecuador |
| repository_id_str | * |
| rights_invalid_str_mv | Derechos de autor 2021 TEODORO JOSE MARIA BARROS ASTUDILLO http://creativecommons.org/licenses/by-nc-nd/4.0 |
| spelling | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology studentsNivel de cumplimiento del uso del dosímetro como norma de protección radiológica de estudiantes de radiologíaBarros-Astudillo , TeodoroOlmedo-Raza , NormanHidalgo-Gualán , Elidadosímetroprotección radiológica radiologíaestudianteradiation dosimeters radiation protectionradiologystudentAbstractIntroduction. The Pan American Health Organization ponders the importance of protection and safety against radiation and radiological emergencies, considering benefits and risks for the uses of radiation in industrial, medical and research applications. The use of radiation also has potential risks to the health of patients, workers (including health personnel), the public, and the environment. The Central University of Ecuador, through the Faculty of Medical Sciences, has the Radiology Career, which trains professionals in this area, with competencies for diagnostic studies, promotion, prevention and research for the benefit of people in a situation of illness; In this context, undergraduate students who carry out pre-professional training practices in health care units, and who are continuously exposed to risks due to ionizing radiation, are enrolled. Objective. Determine the level of compliance with the use of the dosimeter as a radiation protection standard in imaging. Material and methods. The study is descriptive, observational, cross-sectional and analytical. The sample is 58 undergraduate students (seventh and eighth semesters) randomly selected with a 95% confidence level, in the year 2019. Documentary analysis and survey (students and Heads of Radiology Service) were applied. The last three results of the dosimetry tests were analyzed. The reliability statistic of the instrument with Cronbach's Alpha is high (0.833). The data was processed through EXCEL and PSPP. Statistical analyzes were descriptive and a contingency table with Pearson's Chi2 test of independence. Results. The students, men and women, do not regularly use the dosimeter, in the three measurements. By sex, there is a significant difference according to Chi2, in the first measurement and second measurement (p<0.05). In the third measurement, there are no significant differences, but the two groups also do not regularly use the dosimeter. Limitation: The studied sample does not correspond to all the students of the radiology career, prioritizing the last years of training. Conclusions. There is non-compliance in the use of the dosimeter as a radiation protection standard, which increases the chances of health risks for students who carry out pre-professional training practices.Resumen: Introducción. La Organización Panamericana de la Salud (OPS) pondera la importancia en la protección y seguridad contra la radiación y emergencias radiológicas, considerando beneficios y riesgos por los usos de radiaciones en aplicaciones industriales, médicas y de investigación. El uso de la radiación también tiene riesgos potenciales para la salud de pacientes, trabajadores (incluido personal de la salud), población en general y medio ambiente. La Universidad Central del Ecuador, a través de la Facultad de Ciencias Médicas cuenta con la Carrera de Radiología, que forma profesionales en esta área, con competencias para estudios de diagnóstico, promoción, prevención e investigación en beneficio de las personas en situación de enfermedad; en este contexto se inscriben los estudiantes de pregrado que realizan prácticas pre profesionales formativas en las unidades asistenciales de salud, y que se hallan expuestos continuamente a riesgos por radiaciones ionizantes. Objetivo. Determinar el nivel de cumplimiento del uso del dosímetro como norma de protección radiológica en imagenología. Material y Métodos. El estudio es descriptivo, observacional, transversal y analítico. La muestra es de 58 estudiantes de pregrado (séptimo y octavo semestres) seleccionados al azar con el 95% de nivel de confianza, en el año 2019. Se aplicó análisis documental y encuesta (estudiantes y Jefes de Servicio de Radiología). Se analizó los tres últimos resultados de los exámenes de dosimetría. La estadística de fiabilidad del instrumento con Alfa de Cronbach es alta (0,833). Los datos fueron procesados a través EXCEL y SPSS/PC versión 19 de la UCE. Los análisis estadísticos fueron descriptivos y tabla de contingencia con prueba de independencia de Chi2 de Pearson. Resultados. Los estudiantes, hombres y mujeres, no utilizan regularmente el dosímetro, en las tres mediciones. Por sexo, existe diferencia significativa según Chi2, en la primera medición y segunda medición (p<0,05). En la tercera medición, no existen diferencias significativas, pero los dos grupos igualmente no utilizan regularmente el dosímetro. Limitación: La muestra estudiada no corresponde a todos los estudiantes de la carrera de radiología, priorizándose a los últimos años de formación. Conclusiones. Existe incumplimiento en el uso del dosímetro como norma protección radiológica, lo que aumenta posibilidades de riesgos en la salud de los estudiantes que realizan prácticas pre profesionales formativas.Quito: Universidad Central del Ecuador2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistadigital.uce.edu.ec/index.php/CIENCIAS_MEDICAS/article/view/310010.29166/rfcmq.v46i2.3100Revista de la Facultad de Ciencias Médicas (Quito); Vol. 46 No. 2 (2021): Revista de la Facultad de Ciencias Médicas (Quito); 21 - 30Revista de la Facultad de Ciencias Médicas (Quito); Vol. 46 Núm. 2 (2021): Revista de la Facultad de Ciencias Médicas (Quito); 21 - 302737-61412588-0691reponame:Revista Ciencias Médicasinstname:Universidad Central del Ecuadorinstacron:UCEspahttps://revistadigital.uce.edu.ec/index.php/CIENCIAS_MEDICAS/article/view/3100/6619Derechos de autor 2021 TEODORO JOSE MARIA BARROS ASTUDILLOhttp://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccess2023-09-15T14:46:28Zoai:revistadigital.uce.edu.ec:article/3100Portal de revistashttps://revistadigital.uce.edu.ec/Universidad públicahttps://uce.edu.ec/**Ecuador*2737-61412588-0691opendoar:*2023-09-15T14:46:28Revista Ciencias Médicas - Universidad Central del Ecuadorfalse |
| spellingShingle | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students Barros-Astudillo , Teodoro dosímetro protección radiológica radiología estudiante radiation dosimeters radiation protection radiology student |
| status_str | publishedVersion |
| title | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students |
| title_full | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students |
| title_fullStr | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students |
| title_full_unstemmed | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students |
| title_short | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students |
| title_sort | Level of compliance with the use of the dosimeter as a standard of radiological protection of radiology students |
| topic | dosímetro protección radiológica radiología estudiante radiation dosimeters radiation protection radiology student |
| url | https://revistadigital.uce.edu.ec/index.php/CIENCIAS_MEDICAS/article/view/3100 |