SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality
This work describes the design of a SCADA system to improve the drinking water service in the municipality of El Empalme Canton, Ecuador. It outlines the design phases, criteria for analyzing the automation status of the plant, automation design, and device selection. The SCADA system, which uses PL...
Na minha lista:
Autor principal: | |
---|---|
Outros Autores: | , , |
Formato: | article |
Idioma: | spa |
Publicado em: |
2025
|
Assuntos: | |
Acesso em linha: | https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
_version_ | 1838815459765387264 |
---|---|
author | Amaya Jaramillo , Carlos David |
author2 | Guerrero Muñoz, Geovanny Gonzalo Laverde Albarracín, Cristian Samuel Andrade Cedeño, Rogger José |
author2_role | author author author |
author_facet | Amaya Jaramillo , Carlos David Guerrero Muñoz, Geovanny Gonzalo Laverde Albarracín, Cristian Samuel Andrade Cedeño, Rogger José |
author_role | author |
collection | Revista Ingenio |
dc.creator.none.fl_str_mv | Amaya Jaramillo , Carlos David Guerrero Muñoz, Geovanny Gonzalo Laverde Albarracín, Cristian Samuel Andrade Cedeño, Rogger José |
dc.date.none.fl_str_mv | 2025-01-03 |
dc.format.none.fl_str_mv | application/pdf text/html application/epub+zip |
dc.identifier.none.fl_str_mv | https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846 10.29166/ingenio.v8i1.6846 |
dc.language.none.fl_str_mv | spa |
dc.publisher.none.fl_str_mv | Editorial Universitaria - Universidad Central del Ecuador |
dc.relation.none.fl_str_mv | https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846/9414 https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846/9415 https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846/9416 |
dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-nd/4.0 info:eu-repo/semantics/openAccess |
dc.source.none.fl_str_mv | INGENIO; Vol. 8 No. 1 (2025): Specialized Engineering Dissemination; 83-90 INGENIO; Vol. 8 Núm. 1 (2025): Divulgación Especializada en Ingeniería ; 83-90 2697-3243 2588-0829 reponame:Revista Ingenio instname:Universidad Central del Ecuador instacron:UCE |
dc.subject.none.fl_str_mv | automatización comunicación industrial monitoreo en tiempo real control y adquisición de datos Real-time monitoring data acquisition and control automation industrial communication |
dc.title.none.fl_str_mv | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality Sistemas SCADA, Aplicaciones en Plantas Potabilizadoras de Agua de la Costa Ecuatoriana, Caso Municipio del Cantón El Empalme |
dc.type.none.fl_str_mv | info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
description | This work describes the design of a SCADA system to improve the drinking water service in the municipality of El Empalme Canton, Ecuador. It outlines the design phases, criteria for analyzing the automation status of the plant, automation design, and device selection. The SCADA system, which uses PLCs, sensors, and pumps connected via the ModBus TCP protocol, enhanced operational efficiency, reduced response times, and contributed to the quality of the final product. Issues such as imbalances in panel protections and extended response times were addressed through simulation of the automation model. |
eu_rights_str_mv | openAccess |
format | article |
id | REVINGENIO_27d95feb10ae72fa2c2f3cfdf00b1030 |
identifier_str_mv | 10.29166/ingenio.v8i1.6846 |
instacron_str | UCE |
institution | UCE |
instname_str | Universidad Central del Ecuador |
language | spa |
network_acronym_str | REVINGENIO |
network_name_str | Revista Ingenio |
oai_identifier_str | oai:revistadigital.uce.edu.ec:article/6846 |
publishDate | 2025 |
publisher.none.fl_str_mv | Editorial Universitaria - Universidad Central del Ecuador |
reponame_str | Revista Ingenio |
repository.mail.fl_str_mv | * |
repository.name.fl_str_mv | Revista Ingenio - Universidad Central del Ecuador |
repository_id_str | 0 |
rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-nd/4.0 |
spelling | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality Sistemas SCADA, Aplicaciones en Plantas Potabilizadoras de Agua de la Costa Ecuatoriana, Caso Municipio del Cantón El Empalme Amaya Jaramillo , Carlos DavidGuerrero Muñoz, Geovanny GonzaloLaverde Albarracín, Cristian SamuelAndrade Cedeño, Rogger Joséautomatizacióncomunicación industrialmonitoreo en tiempo realcontrol y adquisición de datosReal-time monitoringdata acquisition and controlautomationindustrial communicationThis work describes the design of a SCADA system to improve the drinking water service in the municipality of El Empalme Canton, Ecuador. It outlines the design phases, criteria for analyzing the automation status of the plant, automation design, and device selection. The SCADA system, which uses PLCs, sensors, and pumps connected via the ModBus TCP protocol, enhanced operational efficiency, reduced response times, and contributed to the quality of the final product. Issues such as imbalances in panel protections and extended response times were addressed through simulation of the automation model. resumen Este trabajo describe el diseño de un sistema SCADA para mejorar el servicio de agua potable en el municipio del Cantón El Empalme, Ecuador. Se detallan las fases del diseño, los criterios para el análisis del estado de automatización de la planta, el diseño de la automatización y la selección de dispositivos. El sistema SCADA, que utiliza PLCs, sensores y bombas conectados a través del protocolo ModBus TCP, mejoró la eficiencia operativa, redujo los tiempos de respuesta y contribuyó a la calidad del producto final. Se identificaron problemas como desequilibrio en las protecciones de los tableros y tiempos de respuesta prolongados, los cuales fueron abordados mediante la simulación del modelo de automatización.Editorial Universitaria - Universidad Central del Ecuador2025-01-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlapplication/epub+ziphttps://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/684610.29166/ingenio.v8i1.6846INGENIO; Vol. 8 No. 1 (2025): Specialized Engineering Dissemination; 83-90INGENIO; Vol. 8 Núm. 1 (2025): Divulgación Especializada en Ingeniería ; 83-902697-32432588-0829reponame:Revista Ingenioinstname:Universidad Central del Ecuadorinstacron:UCEspahttps://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846/9414https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846/9415https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846/9416Derechos de autor 2024 Carlos David Amaya Jaramillo , Geovanny Gonzalo Guerrero Muñoz, Cristian Samuel Laverde Albarracín, Rogger José Andrade Cedeñohttp://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccess2025-07-18T16:50:41Zoai:revistadigital.uce.edu.ec:article/6846Portal de revistashttps://revistadigital.uce.edu.ec/Universidad públicahttps://uce.edu.ec/**Ecuador*2697-32432588-0829opendoar:02025-07-18T16:50:41Revista Ingenio - Universidad Central del Ecuadorfalse |
spellingShingle | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality Amaya Jaramillo , Carlos David automatización comunicación industrial monitoreo en tiempo real control y adquisición de datos Real-time monitoring data acquisition and control automation industrial communication |
status_str | publishedVersion |
title | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality |
title_full | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality |
title_fullStr | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality |
title_full_unstemmed | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality |
title_short | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality |
title_sort | SCADA Systems, Applications in Water Treatment Plants along the Ecuadorian Coast Region, Case study: El Empalme Municipality |
topic | automatización comunicación industrial monitoreo en tiempo real control y adquisición de datos Real-time monitoring data acquisition and control automation industrial communication |
url | https://revistadigital.uce.edu.ec/index.php/INGENIO/article/view/6846 |