Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos.
Đã lưu trong:
| Tác giả chính: | |
|---|---|
| Định dạng: | bachelorThesis |
| Ngôn ngữ: | spa |
| Được phát hành: |
2019
|
| Những chủ đề: | |
| Truy cập trực tuyến: | http://repositorio.ug.edu.ec/handle/redug/44416 |
| Các nhãn: |
Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
|
| _version_ | 1858987848047263744 |
|---|---|
| author | López López Carlos Andrés, Morán Delgado Mario David |
| author_facet | López López Carlos Andrés, Morán Delgado Mario David |
| author_role | author |
| collection | Repositorio Universidad de Guayaquil |
| dc.contributor.none.fl_str_mv | Cabrera Montes Fausto |
| dc.creator.none.fl_str_mv | López López Carlos Andrés, Morán Delgado Mario David |
| dc.date.none.fl_str_mv | 2019-10-07T21:33:47Z 2019-10-07T21:33:47Z 2019-04 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | http://repositorio.ug.edu.ec/handle/redug/44416 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Universidad de Guayaquil. Facultad de Ciencias Matemáticas y Físicas. Carrera de Ingeniería Civil |
| dc.relation.none.fl_str_mv | Ejemplar;1 |
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad de Guayaquil instname:Universidad de Guayaquil instacron:UG |
| dc.subject.none.fl_str_mv | Diseño Agregados Hormigón Cemento Hidráulico Resistencia A La Compresión |
| dc.title.none.fl_str_mv | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | PDF |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UG_2ed7c0d9e37cd921041a221376a2ea28 |
| instacron_str | UG |
| institution | UG |
| instname_str | Universidad de Guayaquil |
| language | spa |
| network_acronym_str | UG |
| network_name_str | Repositorio Universidad de Guayaquil |
| oai_identifier_str | oai:repositorio.ug.edu.ec:redug/44416 |
| publishDate | 2019 |
| publisher.none.fl_str_mv | Universidad de Guayaquil. Facultad de Ciencias Matemáticas y Físicas. Carrera de Ingeniería Civil |
| reponame_str | Repositorio Universidad de Guayaquil |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad de Guayaquil - Universidad de Guayaquil |
| repository_id_str | 0 |
| spelling | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos.López López Carlos Andrés, Morán Delgado Mario DavidDiseñoAgregadosHormigónCemento HidráulicoResistencia A La CompresiónPDFEl presente trabajo de titulación se desarrolló en la planta hormigonera “ODCON S.A.”, donde el objetivo principal es reducir los costos de producción mediante la optimización del uso de cemento para hormigones estándar con diferentes tipos de agregados, partiendo desde un diseño patrón obtenido a través de la metodología A.C.I., teniendo como resultado resistencias que sobrepasan a las requeridas por el diseño pudiendo haber un mejor uso de los recursos. Se busca optimizar las relaciones agua/cemento en función de los materiales utilizados y las resistencias obtenidas a los 28 días con un mismo diseño (diseño patrón), la cual fue proporcionada por la hormigonera “ODCON S.A”, para así poder hacer un reajuste de la mezcla para cada agregado propuesto. Este proyecto busca ser un modelo que sirva para obtener un beneficio económico variando los materiales utilizados y las resistencias que se desean alcanzar.The present titration work was developed in the concrete mixer plant "ODCON SA", where the main objective is to reduce production costs by optimizing the use of cement for standard concretes with different types of aggregates, starting from a standard design obtained through of the ACI methodology, resulting in resistances that surpass those required by the design and there may be a better use of resources. The aim is to optimize the water / cement ratios based on the materials used and the resistances obtained after 28 days with the same design (standard design), which was provided by the concrete mixer "ODCON SA", in order to make a readjustment of the the mix for each proposed aggregate. This project seeks to be a model that serves to obtain an economic benefit by varying the materials used and the resistances to be achieved.Universidad de Guayaquil. Facultad de Ciencias Matemáticas y Físicas. Carrera de Ingeniería CivilCabrera Montes Fausto2019-10-07T21:33:47Z2019-10-07T21:33:47Z2019-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://repositorio.ug.edu.ec/handle/redug/44416spaEjemplar;1info:eu-repo/semantics/openAccessreponame:Repositorio Universidad de Guayaquilinstname:Universidad de Guayaquilinstacron:UG2019-10-08T08:01:57Zoai:repositorio.ug.edu.ec:redug/44416Institucionalhttp://repositorio.ug.edu.ec/Universidad públicahttps://www.ug.edu.ec/..Ecuador...opendoar:02026-03-07T06:52:26.903063Repositorio Universidad de Guayaquil - Universidad de Guayaquiltrue |
| spellingShingle | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. López López Carlos Andrés, Morán Delgado Mario David Diseño Agregados Hormigón Cemento Hidráulico Resistencia A La Compresión |
| status_str | publishedVersion |
| title | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| title_full | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| title_fullStr | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| title_full_unstemmed | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| title_short | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| title_sort | Optimización de diseño y producción de hormigón Hidráulico de resistencias f’c = 210, 240, 280 kg/cm² en planta dosificadora con diferentes índole de agregados gruesos. |
| topic | Diseño Agregados Hormigón Cemento Hidráulico Resistencia A La Compresión |
| url | http://repositorio.ug.edu.ec/handle/redug/44416 |