Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro

pdf

Đã lưu trong:
Chi tiết về thư mục
Tác giả chính: Añazco Loaiza, Arturo Guilber (author)
Định dạng: masterThesis
Ngôn ngữ:spa
Được phát hành: 2013
Những chủ đề:
Truy cập trực tuyến:http://repositorio.ug.edu.ec/handle/redug/12025
Các nhãn: Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
_version_ 1858987975646380032
author Añazco Loaiza, Arturo Guilber
author_facet Añazco Loaiza, Arturo Guilber
author_role author
collection Repositorio Universidad de Guayaquil
dc.contributor.none.fl_str_mv Molina Moreira, Natalia
dc.creator.none.fl_str_mv Añazco Loaiza, Arturo Guilber
dc.date.none.fl_str_mv 2013
2016-10-05T15:59:12Z
2016-10-05T15:59:12Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv UG_BFAU_TM_26
http://repositorio.ug.edu.ec/handle/redug/12025
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad de Guayaquil
instname:Universidad de Guayaquil
instacron:UG
dc.subject.none.fl_str_mv PLAN DE MANEJO AMBIENTAL
CONTAMINANTES ORGÁNICOS PERSISTENTES
BIFENILOS POLICLORADOS
DIOXINAS Y FURANOS
PLAGUISIDAS
TRAZAS
CONCIENCIA AMBIENTAL
ECOSISTEMAS
BIOTA
SALUD HUMANA
BIOCUMALARSE
CADENA ALIMENTARIA
dc.title.none.fl_str_mv Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description pdf
eu_rights_str_mv openAccess
format masterThesis
id UG_320364c2fb30f559450dc1734af94cbd
identifier_str_mv UG_BFAU_TM_26
instacron_str UG
institution UG
instname_str Universidad de Guayaquil
language spa
network_acronym_str UG
network_name_str Repositorio Universidad de Guayaquil
oai_identifier_str oai:repositorio.ug.edu.ec:redug/12025
publishDate 2013
reponame_str Repositorio Universidad de Guayaquil
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad de Guayaquil - Universidad de Guayaquil
repository_id_str 0
spelling Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El OroAñazco Loaiza, Arturo GuilberPLAN DE MANEJO AMBIENTALCONTAMINANTES ORGÁNICOS PERSISTENTESBIFENILOS POLICLORADOSDIOXINAS Y FURANOSPLAGUISIDASTRAZASCONCIENCIA AMBIENTALECOSISTEMASBIOTASALUD HUMANABIOCUMALARSECADENA ALIMENTARIApdfLos Contaminantes Orgánicos Persistentes (COPs) son un conjunto de sustancias orgánicas que son persistentes en el ambiente, son capaces de bioacumularse y que poseen características de toxicidad capaces de ocasionar efectos adversos a la salud o al ambiente. Dependiendo de su movilidad en el ambiente, estas sustancias pueden ser de interés local, regional o global, ya que son propensos al transporte atmosférico y marítimo de largo alcance. Como resultado de los Talleres de Priorización llevados a cabo a nivel nacional, por el Ministerio el Ambiente, se determinó que de los tres COPs existentes, la primera prioridad fue para los Bifenilos Policlorados (PCBs); contenidos en los aceites dieléctricos utilizados para la fabricación de transformadores y equipos de protección eléctrica, utilizados por todas las empresas eléctricas del país; la segunda prioridad fue para las emisiones de Dioxinas y Furanos; y tercer prioridad para los plaguicidas. En función de lo expuesto, el presente trabajo pretende promover el manejo de los PCBs, en base a los convenios internacionales de Estocolmo, Basilea y Rotterdam, así como en los lineamientos del Manual de Procedimiento para el Manejo de los PCBs en el Sector Eléctrico Ecuatoriano, para lo cual se ha planteado determinar con el US EPA SW-846Method 9079 que utiliza el kit CLOR-N-OIL-50, la cantidad total de equipos que contienen aceite dieléctrico contaminado con trazas mayores de 50 ppm. Los resultados proyectados, luego de haberse realizado 800 pruebas colorimétricas con los kits CLOR N OIL 50 con el US EPA SW-846 Method 9079 establecieron que en el sistema eléctrico de la CNEL Regional El Oro, se encuentran instalados y en operación aproximadamente entre 5.497 equipos y transformadores contaminados con PCBs, con un total de 411.206 litros de aceite dieléctrico contaminado con trazas mayores a 50 ppm., sin embargo aún no se sabe la ubicación geográfica de aproximadamente 4.593 transformadores xiii de distribución que representan el 52 % con un total de 318.403 litros de aceite dieléctrico contaminado, el mismo que deberá ser retirado según lo programado hasta el año 2020, para lo cual se ha planteado la “Implementación de un Plan de Manejo Ambiental para la Manipulación de Transformadores en el Área de concesión de la CNEL Regional El Oro S.A.”Persistent Organic Pollutants (POPs) are a group of organic substances that are persistent in the environment, are able to bioaccumulate and toxicity have characteristics capable of causing adverse effects to health or the environment. Depending on their mobility in the environment, these substances can be of local, regional or global, as they are prone to atmospheric transport and longrange maritime. As a result of the prioritization workshops conducted nationally by the Environment Ministry, it was determined that the three existing POPs, the first priority was to polychlorinated biphenyls (PCBs) contained in the oils used for manufacturing dielectrics transformers and power protection equipment, used by all utilities in the country, the second priority was for emissions of dioxins and furans, and third priority for pesticides. In view of the above, this paper aims to promote the management of PCBs, based on international conventions Stockholm, Basel and Rotterdam, as well as the guidelines of the Manual of Procedure for the Management of PCBs in the Ecuadorian Electricity Sector , for which it has been raised to determine the 846Method EPA SW-9079 using the kit CLOR-N-OIL-50, the total amount of equipment containing dielectric oil contaminated with trace amounts larger than 50 ppm. The projected results, after 800 colorimetric tests having been realized by the kits CLOR N OIL 50 with the US EPA SW-846 Method 9079 established that in the electrical system of the CNEL Regional El Oro S.A., they are installed and in operation approximately between 5.497 equipments and transformers contaminated with PCBs, with a total of 411.206 liters of oil dielectric contaminated with bigger traces than 50 ppm., nevertheless still there is not known the geographical location of approximately 4.593 distribution transformers that 52 % represents with a total of 318.403 liters of oil dielectric xv contaminated, the same one who will have to be withdrawn according to the programmed until the year 2020, for which has appeared the "Implementation of a Plan of Environmental Managing for the Manipulation of Transformers in the Area of concession of the CNEL Regional El Oro S.A.”Molina Moreira, Natalia2016-10-05T15:59:12Z2016-10-05T15:59:12Z2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfUG_BFAU_TM_26http://repositorio.ug.edu.ec/handle/redug/12025spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad de Guayaquilinstname:Universidad de Guayaquilinstacron:UG2024-10-07T13:58:44Zoai:repositorio.ug.edu.ec:redug/12025Institucionalhttp://repositorio.ug.edu.ec/Universidad públicahttps://www.ug.edu.ec/..Ecuador...opendoar:02026-03-07T06:58:34.925418Repositorio Universidad de Guayaquil - Universidad de Guayaquiltrue
spellingShingle Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
Añazco Loaiza, Arturo Guilber
PLAN DE MANEJO AMBIENTAL
CONTAMINANTES ORGÁNICOS PERSISTENTES
BIFENILOS POLICLORADOS
DIOXINAS Y FURANOS
PLAGUISIDAS
TRAZAS
CONCIENCIA AMBIENTAL
ECOSISTEMAS
BIOTA
SALUD HUMANA
BIOCUMALARSE
CADENA ALIMENTARIA
status_str publishedVersion
title Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
title_full Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
title_fullStr Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
title_full_unstemmed Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
title_short Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
title_sort Implementación de un plan de manejo ambiental para la manipulación de transformadores en el área de concesión de la cnel regional El Oro
topic PLAN DE MANEJO AMBIENTAL
CONTAMINANTES ORGÁNICOS PERSISTENTES
BIFENILOS POLICLORADOS
DIOXINAS Y FURANOS
PLAGUISIDAS
TRAZAS
CONCIENCIA AMBIENTAL
ECOSISTEMAS
BIOTA
SALUD HUMANA
BIOCUMALARSE
CADENA ALIMENTARIA
url http://repositorio.ug.edu.ec/handle/redug/12025