Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.

Abode PDF

Сохранить в:
Библиографические подробности
Главный автор: Zambrano Lino, César Eduardo (author)
Формат: bachelorThesis
Язык:spa
Опубликовано: 2018
Предметы:
Online-ссылка:http://repositorio.ug.edu.ec/handle/redug/32385
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!
_version_ 1840595399267581952
author Zambrano Lino, César Eduardo
author_facet Zambrano Lino, César Eduardo
author_role author
collection Repositorio Universidad de Guayaquil
dc.contributor.none.fl_str_mv Palomeque Freire, Leonardo
dc.creator.none.fl_str_mv Zambrano Lino, César Eduardo
dc.date.none.fl_str_mv 2018-09-12T17:02:49Z
2018-09-12T17:02:49Z
2018-01
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://repositorio.ug.edu.ec/handle/redug/32385
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Universidad de Guayaquil. Facultad de Ciencias Matemáticas y Físicas. Carrera de Ingeniería Civil.
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad de Guayaquil
instname:Universidad de Guayaquil
instacron:UG
dc.subject.none.fl_str_mv ANALISIS COMPARATIVO
SISTEMAS DE AISLACIÓN SISMICO
NEC-15/AISLADOR TIPO HDRB
CORTE BASAL
VULNERABILIDAD SÍSMICA.
dc.title.none.fl_str_mv Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description Abode PDF
eu_rights_str_mv openAccess
format bachelorThesis
id UG_7dfe5308c41bef22d061bcf94e00d0a8
instacron_str UG
institution UG
instname_str Universidad de Guayaquil
language spa
network_acronym_str UG
network_name_str Repositorio Universidad de Guayaquil
oai_identifier_str oai:repositorio.ug.edu.ec:redug/32385
publishDate 2018
publisher.none.fl_str_mv Universidad de Guayaquil. Facultad de Ciencias Matemáticas y Físicas. Carrera de Ingeniería Civil.
reponame_str Repositorio Universidad de Guayaquil
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad de Guayaquil - Universidad de Guayaquil
repository_id_str 0
spelling Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.Zambrano Lino, César EduardoANALISIS COMPARATIVOSISTEMAS DE AISLACIÓN SISMICONEC-15/AISLADOR TIPO HDRBCORTE BASALVULNERABILIDAD SÍSMICA.Abode PDFEl presente trabajo de investigación, tiene como objetivo realizar un análisis comparativo de resultados en el comportamiento de un edificio con el sistema de aislación sísmica vs un edificio de base fija, en el cual hemos usado el tipo aislador de base HDRB (High-Damping Rubber Bearing). Basado en la idea de reducir la demanda sísmica en vez de aumentar la capacidad de resistencia de la estructura, el aislamiento sísmico es un método simple de reducir los daños que producen los terremotos hacia la estructura. El diseño del aislador sísmico fue realizado con las normas chilenas NCH 2745 y NCH 433 y ejecutado con el programa de diseño y análisis estructural ETAB’s, ofreciéndonos un ejemplo del comportamiento de los elemento que conforma la estructura durante un sismo, los diseños de cada elemento estructural fue corroborado con ayuda de la Norma Ecuatoriana de la Construcción (NEC-15) y American Concrete Institute (ACI 318-14), Finalmente se realiza un análisis comparativo de los resultados obtenidos por el programa ETAB’s entre la edificación con el sistema de aislamiento sísmico y la edificación de base fija.The present research work, has as purpose to perform a comparative analysis of results between the behavior of a building with the seismic insulation system and on the other hand a fixed base building in which we have the type of base insulator HDRB ( High-Damping Rubber Bearing). Based on the idea of reducing seismic demand rather than increasing the resilience of the structure, the seismic isolation is a simple method of reducing the damage that earthquakes cause to the structure. The design of the seismic isolator was carried out under Chilean Norms NCH 2745 y NCH 433 and executed with the modeling program ETAB’s, obtaining a clear example of the behavior of each element that forms the structure during an earthquake. The designs of each structural element were corroborated with the help of the entity Ecuadorian Construction Standard (NEC -15) and American Concrete Institute (ACI 318- 14). Finally, we compared and evaluated the advantages and benefits that the structure would obtain with the seismic isolation vs the conventional built structure, guaranteeing to reduce damages caused by earthquakes and loss of human lives.Universidad de Guayaquil. Facultad de Ciencias Matemáticas y Físicas. Carrera de Ingeniería Civil.Palomeque Freire, Leonardo2018-09-12T17:02:49Z2018-09-12T17:02:49Z2018-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://repositorio.ug.edu.ec/handle/redug/32385spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad de Guayaquilinstname:Universidad de Guayaquilinstacron:UG2018-09-13T08:15:53Zoai:repositorio.ug.edu.ec:redug/32385Institucionalhttp://repositorio.ug.edu.ec/Universidad públicahttps://www.ug.edu.ec/..Ecuador...opendoar:02025-08-16T06:45:04.647922Repositorio Universidad de Guayaquil - Universidad de Guayaquiltrue
spellingShingle Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
Zambrano Lino, César Eduardo
ANALISIS COMPARATIVO
SISTEMAS DE AISLACIÓN SISMICO
NEC-15/AISLADOR TIPO HDRB
CORTE BASAL
VULNERABILIDAD SÍSMICA.
status_str publishedVersion
title Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
title_full Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
title_fullStr Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
title_full_unstemmed Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
title_short Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
title_sort Influencia en la colocación de aisladores sísmicos en el comportamiento estructural de un edificio de cinco plantas.
topic ANALISIS COMPARATIVO
SISTEMAS DE AISLACIÓN SISMICO
NEC-15/AISLADOR TIPO HDRB
CORTE BASAL
VULNERABILIDAD SÍSMICA.
url http://repositorio.ug.edu.ec/handle/redug/32385