Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores

PDF

Gardado en:
Detalles Bibliográficos
Autor Principal: Rodríguez Cruz, Rony Alexander (author)
Formato: bachelorThesis
Idioma:spa
Publicado: 2020
Subjects:
Acceso en liña:http://repositorio.ug.edu.ec/handle/redug/48478
Tags: Engadir etiqueta
Sen Etiquetas, Sexa o primeiro en etiquetar este rexistro!
_version_ 1858987805410066432
author Rodríguez Cruz, Rony Alexander
author_facet Rodríguez Cruz, Rony Alexander
author_role author
collection Repositorio Universidad de Guayaquil
dc.contributor.none.fl_str_mv Marcalupo Llerena, Sara Isabel
dc.creator.none.fl_str_mv Rodríguez Cruz, Rony Alexander
dc.date.none.fl_str_mv 2020-06-12T22:14:17Z
2020-06-12T22:14:17Z
2020-06
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv 3327
http://repositorio.ug.edu.ec/handle/redug/48478
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Universidad de Guayaquil. Facultad Piloto de Odontología
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad de Guayaquil
instname:Universidad de Guayaquil
instacron:UG
dc.subject.none.fl_str_mv CONDUCTO RADICULAR
SISTEMAS ROTATORIOS
ENDODONCIA
dc.title.none.fl_str_mv Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description PDF
eu_rights_str_mv openAccess
format bachelorThesis
id UG_9174e7583010d99824e093efff91bc21
identifier_str_mv 3327
instacron_str UG
institution UG
instname_str Universidad de Guayaquil
language spa
network_acronym_str UG
network_name_str Repositorio Universidad de Guayaquil
oai_identifier_str oai:repositorio.ug.edu.ec:redug/48478
publishDate 2020
publisher.none.fl_str_mv Universidad de Guayaquil. Facultad Piloto de Odontología
reponame_str Repositorio Universidad de Guayaquil
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad de Guayaquil - Universidad de Guayaquil
repository_id_str 0
spelling Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posterioresRodríguez Cruz, Rony AlexanderCONDUCTO RADICULARSISTEMAS ROTATORIOSENDODONCIAPDFEl objetivo de este trabajo fue verificar las variaciones de amplitud alcanzadas por los Sistemas Rotatorios Protaper Next y Universal. Se realizó una revisión bibliográfica de los últimos 5 años acerca de instrumentación rotatoria, buscando ventajas y desventajas, sobretodo se revisó las variaciones de incremento de amplitud entre ambos sistemas. El estudio in-vitro fue realizado en 30 premolares naturales con características específicas, curvatura menor de 5°, sin reabsorción interna y externa, sin conductos calcificados, dos raíces y dos conductos. Los dientes fueron descontaminados con solución de timol. Posteriormente se realizaron cortes con un disco de diamante, excluyendo la corona y dividiendo las raíces, se las colocó en un bloque de acrílico individualmente y se procedió a tomar radiografías en dos sentidos vestíbulo-palatino y mesio-distal pre operatorias. 15 dientes fueron instrumentados de acuerdo al protocolo correspondiente a las limas Protaper Next y las 15 muestras restantes fueron instrumentadas siguiendo el protocolo de las limas ProTaper Universal. Se tomaron las radiografías post operatorias en los métodos antes mencionados. Se utilizó Adobe Ilustrator para poder realizar las respectivas medidas por tercios de los conductos pre-instrumentados y post instrumentados. Los resultados revelaron que Las limas Protaper Universal alcanzaron incrementos de amplitud en todos los tercios de los conductos que las limas Protaper Next.The objective of this research is to verify the effectiveness of the Protaper Next and Universal Rotatory systems. A bibliographic review of the last 5 years was made on rotary instrumentation, looking for advantages and disadvantages, especially a comparison the aforementioned systems about the amplitude increase. The in vitro study was made in 30 natural premolars with specific features, curvature less than 5 °, without internal and external resorption, calcified root canals, two roots and two root canals. Teeth were decontaminated with thymol solution. After that, cuts were made with a diamond disk, excluding the crown and dividing the roots, they were placed individually in an acrylic block and then two-way vestibule-palatine and mesio-distal preoperative radiographs were taken. 15 teeth were instrumented according to the protocol corresponding to the Protaper Next files and the remaining 15 samples were instrumented by following the protocol of the Protaper Universal files. Post-operative radiographs were taken in the methods explained before. Adobe Illustrator was used to do the respective measurements by thirds of the pre-instrumented and post instrumented ducts. Results revealed that Protaper Universal files achieved enlargement increments in all thirds of the root canal than the Protaper Next files, which in most of the samples and other researches the variation in amplitude of increase between them were significantly high.Universidad de Guayaquil. Facultad Piloto de OdontologíaMarcalupo Llerena, Sara Isabel2020-06-12T22:14:17Z2020-06-12T22:14:17Z2020-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdf3327http://repositorio.ug.edu.ec/handle/redug/48478spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad de Guayaquilinstname:Universidad de Guayaquilinstacron:UG2020-06-30T08:08:51Zoai:repositorio.ug.edu.ec:redug/48478Institucionalhttp://repositorio.ug.edu.ec/Universidad públicahttps://www.ug.edu.ec/..Ecuador...opendoar:02026-03-07T06:50:19.888768Repositorio Universidad de Guayaquil - Universidad de Guayaquiltrue
spellingShingle Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
Rodríguez Cruz, Rony Alexander
CONDUCTO RADICULAR
SISTEMAS ROTATORIOS
ENDODONCIA
status_str publishedVersion
title Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
title_full Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
title_fullStr Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
title_full_unstemmed Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
title_short Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
title_sort Utilización de Limas Rotatorias Protaper Next y Universal en la Preparación de conductos radiculares en dientes posteriores
topic CONDUCTO RADICULAR
SISTEMAS ROTATORIOS
ENDODONCIA
url http://repositorio.ug.edu.ec/handle/redug/48478