Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.

The connection reduced beam section and concrete filled box column is an unqualified connection, however, it is one of the most used in Ecuador according to several authors, the same authors who demonstrated that it has a good performance as long as it complies with several design and construction r...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Vallejo Ricaurte, Marco Paúl (author)
Formato: bachelorThesis
Idioma:spa
Publicado em: 2021
Assuntos:
Acesso em linha:http://dspace.unach.edu.ec/handle/51000/7829
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
_version_ 1858382454113435648
author Vallejo Ricaurte, Marco Paúl
author_facet Vallejo Ricaurte, Marco Paúl
author_role author
collection Repositorio Universidad Nacional de Chimborazo
dc.contributor.none.fl_str_mv Hidalgo Robalino, Diego Hernán
dc.creator.none.fl_str_mv Vallejo Ricaurte, Marco Paúl
dc.date.none.fl_str_mv 2021-07-02T15:06:37Z
2021-07-02T15:06:37Z
2021-07-02
dc.format.none.fl_str_mv 94 páginas
dc.identifier.none.fl_str_mv UNACH-FI-CIV
http://dspace.unach.edu.ec/handle/51000/7829
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Riobamba Universidad Nacional de Chimborazo
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Chimborazo
instname:Universidad Nacional de Chimborazo
instacron:UNACH
dc.subject.none.fl_str_mv CONEXIÓN VIGA
COLUMNA, RÓTULA PLÁSTICA
PROCESO CONSTRUCTIVO
REQUERIMIENTOS
dc.title.none.fl_str_mv Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The connection reduced beam section and concrete filled box column is an unqualified connection, however, it is one of the most used in Ecuador according to several authors, the same authors who demonstrated that it has a good performance as long as it complies with several design and construction requirements present in American codes, which were compiled in this work. In this thesis was elaborated a check list with relevant information that was used in three buildings in our country to recognize errors in the connection studied, such as: placing RBS beams in cantilevers, not removing the backing plate under the bottom skid of the beam, poor design of the shear plate, placing lateral bracing or other elements in the protected zone of the beam, among other errors, and subsequently, a detailed analysis of the mistake was made, with possible consequences that may result, accompanied by a photo of the error and what should have been done according to the codes. In addition, since there is no constructive procedure for this connection in the normatives and codes, it was developed very detailed based on field observation and recommendations from American codes. The procedure was validated through a survey of experts on the subject and they agreed that it is clear, concise and can even be used on site.
eu_rights_str_mv openAccess
format bachelorThesis
id UNACH_1cfbb238b2e9ecbac4bf51ee2a683bbf
identifier_str_mv UNACH-FI-CIV
instacron_str UNACH
institution UNACH
instname_str Universidad Nacional de Chimborazo
language spa
network_acronym_str UNACH
network_name_str Repositorio Universidad Nacional de Chimborazo
oai_identifier_str oai:localhost:51000/7829
publishDate 2021
publisher.none.fl_str_mv Riobamba Universidad Nacional de Chimborazo
reponame_str Repositorio Universidad Nacional de Chimborazo
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazo
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.Vallejo Ricaurte, Marco PaúlCONEXIÓN VIGACOLUMNA, RÓTULA PLÁSTICAPROCESO CONSTRUCTIVOREQUERIMIENTOSThe connection reduced beam section and concrete filled box column is an unqualified connection, however, it is one of the most used in Ecuador according to several authors, the same authors who demonstrated that it has a good performance as long as it complies with several design and construction requirements present in American codes, which were compiled in this work. In this thesis was elaborated a check list with relevant information that was used in three buildings in our country to recognize errors in the connection studied, such as: placing RBS beams in cantilevers, not removing the backing plate under the bottom skid of the beam, poor design of the shear plate, placing lateral bracing or other elements in the protected zone of the beam, among other errors, and subsequently, a detailed analysis of the mistake was made, with possible consequences that may result, accompanied by a photo of the error and what should have been done according to the codes. In addition, since there is no constructive procedure for this connection in the normatives and codes, it was developed very detailed based on field observation and recommendations from American codes. The procedure was validated through a survey of experts on the subject and they agreed that it is clear, concise and can even be used on site.La conexión viga de sección reducida y columna cajón rellena de hormigón es una conexión no calificada, sin embargo, es una de las más utilizadas en Ecuador según varios autores, autores que demostraron que posee un buen comportamiento siempre y cuando cumpla con varios requerimientos de diseño y construcción presentes en códigos americanos, mismos se compilaron en este trabajo. En esta tesis se elaboró una ficha con información relevante (check list) que se la utilizó en tres edificaciones de nuestro medio con la finalidad de reconocer errores en la conexión estudiada como por ejemplo: colocar vigas RBS en voladizos, no remover la placa de respaldo bajo el patín inferior de la viga, mal diseño de la placa de corte, colocar arrostramiento lateral u otros elementos en la zona protegida de la viga, entre otros errores y posteriormente, se realizó un análisis detallado de la equivocación, con posibles consecuencias, acompañado de una foto del error y lo que se debió realizar al inicio aplicando los códigos. Además, en vista de que tanto en normativas como en los códigos no existe un procedimiento constructivo acerca de esta conexión, se desarrolló uno muy detallado y realizado en base a observación en campo y recomendaciones de códigos americanos. El procedimiento fue validado a través de una encuesta realizada a expertos en el tema y coincidieron en que es claro, conciso y que incluso puede ser utilizado en obra.UNACH, EcuadorRiobamba Universidad Nacional de ChimborazoHidalgo Robalino, Diego Hernán2021-07-02T15:06:37Z2021-07-02T15:06:37Z2021-07-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis94 páginasUNACH-FI-CIVhttp://dspace.unach.edu.ec/handle/51000/7829spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Chimborazoinstname:Universidad Nacional de Chimborazoinstacron:UNACH2021-11-20T08:08:34Zoai:localhost:51000/7829Institucionalhttp://dspace.unach.edu.ec/Universidad públicahttps://www.unach.edu.ec/http://dspace.unach.edu.ec/oai.Ecuador...opendoar:02021-11-20T08:08:34Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazofalse
spellingShingle Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
Vallejo Ricaurte, Marco Paúl
CONEXIÓN VIGA
COLUMNA, RÓTULA PLÁSTICA
PROCESO CONSTRUCTIVO
REQUERIMIENTOS
status_str publishedVersion
title Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
title_full Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
title_fullStr Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
title_full_unstemmed Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
title_short Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
title_sort Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
topic CONEXIÓN VIGA
COLUMNA, RÓTULA PLÁSTICA
PROCESO CONSTRUCTIVO
REQUERIMIENTOS
url http://dspace.unach.edu.ec/handle/51000/7829