Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.
The connection reduced beam section and concrete filled box column is an unqualified connection, however, it is one of the most used in Ecuador according to several authors, the same authors who demonstrated that it has a good performance as long as it complies with several design and construction r...
Na minha lista:
| Autor principal: | |
|---|---|
| Formato: | bachelorThesis |
| Idioma: | spa |
| Publicado em: |
2021
|
| Assuntos: | |
| Acesso em linha: | http://dspace.unach.edu.ec/handle/51000/7829 |
| Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
| _version_ | 1858382454113435648 |
|---|---|
| author | Vallejo Ricaurte, Marco Paúl |
| author_facet | Vallejo Ricaurte, Marco Paúl |
| author_role | author |
| collection | Repositorio Universidad Nacional de Chimborazo |
| dc.contributor.none.fl_str_mv | Hidalgo Robalino, Diego Hernán |
| dc.creator.none.fl_str_mv | Vallejo Ricaurte, Marco Paúl |
| dc.date.none.fl_str_mv | 2021-07-02T15:06:37Z 2021-07-02T15:06:37Z 2021-07-02 |
| dc.format.none.fl_str_mv | 94 páginas |
| dc.identifier.none.fl_str_mv | UNACH-FI-CIV http://dspace.unach.edu.ec/handle/51000/7829 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Riobamba Universidad Nacional de Chimborazo |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Nacional de Chimborazo instname:Universidad Nacional de Chimborazo instacron:UNACH |
| dc.subject.none.fl_str_mv | CONEXIÓN VIGA COLUMNA, RÓTULA PLÁSTICA PROCESO CONSTRUCTIVO REQUERIMIENTOS |
| dc.title.none.fl_str_mv | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | The connection reduced beam section and concrete filled box column is an unqualified connection, however, it is one of the most used in Ecuador according to several authors, the same authors who demonstrated that it has a good performance as long as it complies with several design and construction requirements present in American codes, which were compiled in this work. In this thesis was elaborated a check list with relevant information that was used in three buildings in our country to recognize errors in the connection studied, such as: placing RBS beams in cantilevers, not removing the backing plate under the bottom skid of the beam, poor design of the shear plate, placing lateral bracing or other elements in the protected zone of the beam, among other errors, and subsequently, a detailed analysis of the mistake was made, with possible consequences that may result, accompanied by a photo of the error and what should have been done according to the codes. In addition, since there is no constructive procedure for this connection in the normatives and codes, it was developed very detailed based on field observation and recommendations from American codes. The procedure was validated through a survey of experts on the subject and they agreed that it is clear, concise and can even be used on site. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UNACH_1cfbb238b2e9ecbac4bf51ee2a683bbf |
| identifier_str_mv | UNACH-FI-CIV |
| instacron_str | UNACH |
| institution | UNACH |
| instname_str | Universidad Nacional de Chimborazo |
| language | spa |
| network_acronym_str | UNACH |
| network_name_str | Repositorio Universidad Nacional de Chimborazo |
| oai_identifier_str | oai:localhost:51000/7829 |
| publishDate | 2021 |
| publisher.none.fl_str_mv | Riobamba Universidad Nacional de Chimborazo |
| reponame_str | Repositorio Universidad Nacional de Chimborazo |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazo |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes.Vallejo Ricaurte, Marco PaúlCONEXIÓN VIGACOLUMNA, RÓTULA PLÁSTICAPROCESO CONSTRUCTIVOREQUERIMIENTOSThe connection reduced beam section and concrete filled box column is an unqualified connection, however, it is one of the most used in Ecuador according to several authors, the same authors who demonstrated that it has a good performance as long as it complies with several design and construction requirements present in American codes, which were compiled in this work. In this thesis was elaborated a check list with relevant information that was used in three buildings in our country to recognize errors in the connection studied, such as: placing RBS beams in cantilevers, not removing the backing plate under the bottom skid of the beam, poor design of the shear plate, placing lateral bracing or other elements in the protected zone of the beam, among other errors, and subsequently, a detailed analysis of the mistake was made, with possible consequences that may result, accompanied by a photo of the error and what should have been done according to the codes. In addition, since there is no constructive procedure for this connection in the normatives and codes, it was developed very detailed based on field observation and recommendations from American codes. The procedure was validated through a survey of experts on the subject and they agreed that it is clear, concise and can even be used on site.La conexión viga de sección reducida y columna cajón rellena de hormigón es una conexión no calificada, sin embargo, es una de las más utilizadas en Ecuador según varios autores, autores que demostraron que posee un buen comportamiento siempre y cuando cumpla con varios requerimientos de diseño y construcción presentes en códigos americanos, mismos se compilaron en este trabajo. En esta tesis se elaboró una ficha con información relevante (check list) que se la utilizó en tres edificaciones de nuestro medio con la finalidad de reconocer errores en la conexión estudiada como por ejemplo: colocar vigas RBS en voladizos, no remover la placa de respaldo bajo el patín inferior de la viga, mal diseño de la placa de corte, colocar arrostramiento lateral u otros elementos en la zona protegida de la viga, entre otros errores y posteriormente, se realizó un análisis detallado de la equivocación, con posibles consecuencias, acompañado de una foto del error y lo que se debió realizar al inicio aplicando los códigos. Además, en vista de que tanto en normativas como en los códigos no existe un procedimiento constructivo acerca de esta conexión, se desarrolló uno muy detallado y realizado en base a observación en campo y recomendaciones de códigos americanos. El procedimiento fue validado a través de una encuesta realizada a expertos en el tema y coincidieron en que es claro, conciso y que incluso puede ser utilizado en obra.UNACH, EcuadorRiobamba Universidad Nacional de ChimborazoHidalgo Robalino, Diego Hernán2021-07-02T15:06:37Z2021-07-02T15:06:37Z2021-07-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis94 páginasUNACH-FI-CIVhttp://dspace.unach.edu.ec/handle/51000/7829spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Chimborazoinstname:Universidad Nacional de Chimborazoinstacron:UNACH2021-11-20T08:08:34Zoai:localhost:51000/7829Institucionalhttp://dspace.unach.edu.ec/Universidad públicahttps://www.unach.edu.ec/http://dspace.unach.edu.ec/oai.Ecuador...opendoar:02021-11-20T08:08:34Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazofalse |
| spellingShingle | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. Vallejo Ricaurte, Marco Paúl CONEXIÓN VIGA COLUMNA, RÓTULA PLÁSTICA PROCESO CONSTRUCTIVO REQUERIMIENTOS |
| status_str | publishedVersion |
| title | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| title_full | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| title_fullStr | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| title_full_unstemmed | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| title_short | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| title_sort | Parámetros para procedimiento de diseño y construcción de la conexión viga “I” de sección reducida – columna cajón rellena para edificaciones sismorresistentes. |
| topic | CONEXIÓN VIGA COLUMNA, RÓTULA PLÁSTICA PROCESO CONSTRUCTIVO REQUERIMIENTOS |
| url | http://dspace.unach.edu.ec/handle/51000/7829 |