Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019

ABSTRACT This research analyzes the effectiveness of the sterilization cycle in autoclaves in health centers in the city of Riobamba. It had a qualitative, descriptive, observational, cross-sectional cohort approach, in which 6 autoclaves were evaluated with loads of 0%, 25%, 50%, 75% and 100%, in t...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Jenny Paola, Defáz Torres (author)
Formato: bachelorThesis
Idioma:spa
Publicado em: 2021
Assuntos:
Acesso em linha:http://dspace.unach.edu.ec/handle/51000/8405
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
_version_ 1858382458586660864
author Jenny Paola, Defáz Torres
author_facet Jenny Paola, Defáz Torres
author_role author
collection Repositorio Universidad Nacional de Chimborazo
dc.contributor.none.fl_str_mv Carlos, Espinoza Chávez
dc.creator.none.fl_str_mv Jenny Paola, Defáz Torres
dc.date.none.fl_str_mv 2021-12-07T11:40:28Z
2021-12-07T11:40:28Z
2021-12-07
dc.format.none.fl_str_mv 70p.
dc.identifier.none.fl_str_mv Jenny Paola D,(2021)(Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019)(Tesis de pregrado)Universidad Nacional de Chimborazo, Riobamba, Ecuador
UNACH-FCS-ODO
http://dspace.unach.edu.ec/handle/51000/8405
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Universidad Nacional de Chimborazo
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Chimborazo
instname:Universidad Nacional de Chimborazo
instacron:UNACH
dc.subject.none.fl_str_mv Autoclave
esterilización
odontología
indicadores biológicos
dc.title.none.fl_str_mv Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description ABSTRACT This research analyzes the effectiveness of the sterilization cycle in autoclaves in health centers in the city of Riobamba. It had a qualitative, descriptive, observational, cross-sectional cohort approach, in which 6 autoclaves were evaluated with loads of 0%, 25%, 50%, 75% and 100%, in the dental service units; Three autoclaves at the General Teaching Hospital of Riobamba, one autoclave at the Alfonso Villagómez Pediatric Hospital, one autoclave at the Santa Rosa Health Center and one autoclave at the Calpi Health Center, using the biological indicators in different locations within the equipment (front, center and back) for each load. According to the results obtained, the biological indicators used in the processes without load (0%) and with a load of 25%, in front, middle and back positions were effective in all the sub-centers evaluated, however, the results with loads of 50%, 75% and 100% located in front, middle and back of the equipment showed deficiencies with ineffective markers in the sub-centers some sub-centers with the exception of sub-center 3 (Santa Rosa Health Center) in which the sterilization process was effective in all the loads and sites where the biological indicators were located. It is concluded that the effective loads are evidenced in all the positions in values no greater than 25%. Keywords: Autoclave, sterilization, dentistry, biological indicators, sanitary devices.
eu_rights_str_mv openAccess
format bachelorThesis
id UNACH_2715de05bb1d1cd4512e660ee42e86f7
identifier_str_mv Jenny Paola D,(2021)(Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019)(Tesis de pregrado)Universidad Nacional de Chimborazo, Riobamba, Ecuador
UNACH-FCS-ODO
instacron_str UNACH
institution UNACH
instname_str Universidad Nacional de Chimborazo
language spa
network_acronym_str UNACH
network_name_str Repositorio Universidad Nacional de Chimborazo
oai_identifier_str oai:localhost:51000/8405
publishDate 2021
publisher.none.fl_str_mv Universidad Nacional de Chimborazo
reponame_str Repositorio Universidad Nacional de Chimborazo
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazo
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019Jenny Paola, Defáz TorresAutoclaveesterilizaciónodontologíaindicadores biológicosABSTRACT This research analyzes the effectiveness of the sterilization cycle in autoclaves in health centers in the city of Riobamba. It had a qualitative, descriptive, observational, cross-sectional cohort approach, in which 6 autoclaves were evaluated with loads of 0%, 25%, 50%, 75% and 100%, in the dental service units; Three autoclaves at the General Teaching Hospital of Riobamba, one autoclave at the Alfonso Villagómez Pediatric Hospital, one autoclave at the Santa Rosa Health Center and one autoclave at the Calpi Health Center, using the biological indicators in different locations within the equipment (front, center and back) for each load. According to the results obtained, the biological indicators used in the processes without load (0%) and with a load of 25%, in front, middle and back positions were effective in all the sub-centers evaluated, however, the results with loads of 50%, 75% and 100% located in front, middle and back of the equipment showed deficiencies with ineffective markers in the sub-centers some sub-centers with the exception of sub-center 3 (Santa Rosa Health Center) in which the sterilization process was effective in all the loads and sites where the biological indicators were located. It is concluded that the effective loads are evidenced in all the positions in values no greater than 25%. Keywords: Autoclave, sterilization, dentistry, biological indicators, sanitary devices.RESUMEN La presente investigación analiza la eficacia del ciclo de esterilización en autoclaves, de los centros de salud de la ciudad de Riobamba. La misma tuvo un enfoque de tipo cualitativo, descriptivo, observacional, de cohorte transversal; en la que se evaluó 6 autoclaves con cargas del 0%, 25%, 50%, 75% y 100%, en las unidades de servicios odontológicos; tres autoclaves del Hospital General Docente de Riobamba, un autoclave del Hospital Pediátrico Alfonso Villagómez, un autoclave en el Centro de Salud Santa Rosa y un autoclave del Centro de Salud Calpi, usando los indicadores biológicos en diferentes ubicaciones dentro del equipo (adelante, centro y atrás) en cada carga, también se aplicó una encuesta a las personas que se encargan del proceso de esterilización en el área de odontología de los centros de salud mencionados. Según los resultados obtenidos los indicadores biológicos utilizados en los procesos sin carga (0%) y con carga del 25%, en posiciones adelante, en medio y atrás fueron eficaces en todos los subcentros evaluados, sin embargo los resultados con cargas del 50%, 75% y 100% ubicados adelante, centro y atrás de los equipos mostraron deficiencias con marcadores ineficaces en algunos subcentros a excepción del subcentro 3 (Hospital Pediátrico Alfonso Villagómez) en que el proceso de esterilización fue eficaz en todas las cargas y sitios en los que se ubicaron los indicadores biológicos. Se concluye que las cargas efectivas se evidencias en todas las posiciones en valores no mayores al 25%.UNACH, EcuadorUniversidad Nacional de ChimborazoCarlos, Espinoza Chávez2021-12-07T11:40:28Z2021-12-07T11:40:28Z2021-12-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis70p.Jenny Paola D,(2021)(Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019)(Tesis de pregrado)Universidad Nacional de Chimborazo, Riobamba, EcuadorUNACH-FCS-ODOhttp://dspace.unach.edu.ec/handle/51000/8405spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Chimborazoinstname:Universidad Nacional de Chimborazoinstacron:UNACH2022-04-05T08:05:05Zoai:localhost:51000/8405Institucionalhttp://dspace.unach.edu.ec/Universidad públicahttps://www.unach.edu.ec/http://dspace.unach.edu.ec/oai.Ecuador...opendoar:02022-04-05T08:05:05Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazofalse
spellingShingle Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
Jenny Paola, Defáz Torres
Autoclave
esterilización
odontología
indicadores biológicos
status_str publishedVersion
title Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
title_full Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
title_fullStr Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
title_full_unstemmed Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
title_short Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
title_sort Eficacia del ciclo de esterilización en autoclaves, centros de salud Riobamba, 2019
topic Autoclave
esterilización
odontología
indicadores biológicos
url http://dspace.unach.edu.ec/handle/51000/8405