Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).

This work presents the design of a submersible optical system for the transmission and reception of signals in the ultraviolet range (200 nm to 400 nm), aimed at identifying contaminants in experimental water samples. The system seeks to provide an efficient and accurate tool for detecting harmful s...

Olles dieđut

Furkejuvvon:
Bibliográfalaš dieđut
Váldodahkki: López Lucio, Carlos Daniel (author)
Materiálatiipa: bachelorThesis
Giella:spa
Almmustuhtton: 2025
Fáttát:
Liŋkkat:http://dspace.unach.edu.ec/handle/51000/14472
Fáddágilkorat: Lasit fáddágilkoriid
Eai fáddágilkorat, Lasit vuosttaš fáddágilkora!
_version_ 1839991870484119552
author López Lucio, Carlos Daniel
author_facet López Lucio, Carlos Daniel
author_role author
collection Repositorio Universidad Nacional de Chimborazo
dc.contributor.none.fl_str_mv Escudero Villa, Pedro Fernando
dc.creator.none.fl_str_mv López Lucio, Carlos Daniel
dc.date.none.fl_str_mv 2025-01-07T20:14:22Z
2025-01-07T20:14:22Z
2025-01-07
dc.format.none.fl_str_mv 70 páginas.
dc.identifier.none.fl_str_mv López L., Carlos D. (2024). Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV). (Tesis de grado). Universidad Nacional de Chimborazo. Riobamba, Ecuador.
UNACH-EC-FI-ITEL
http://dspace.unach.edu.ec/handle/51000/14472
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Riobamba
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Chimborazo
instname:Universidad Nacional de Chimborazo
instacron:UNACH
dc.subject.none.fl_str_mv Espectrometría
Contaminantes de agua
Instrumentación portátil
Transmisor-receptor.
dc.title.none.fl_str_mv Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description This work presents the design of a submersible optical system for the transmission and reception of signals in the ultraviolet range (200 nm to 400 nm), aimed at identifying contaminants in experimental water samples. The system seeks to provide an efficient and accurate tool for detecting harmful substances by analyzing the spectral interactions of UV light with contaminants present in water. The system design includes two main modules: an optical transmitter, which emits UV light signals within a controlled range, and an optical receiver, responsible for capturing and analyzing the spectral response of the aquatic medium. The transmitter is based on ultraviolet light sources calibrated to operate within the specified range, while the receiver employs highly sensitive and selective optical sensors capable of recording changes in the intensity and wavelength of light after interacting with contaminants. Additionally, a robust submersible structure was designed to withstand adverse conditions, ensuring reliable operation in aquatic environments with varying levels of turbidity and temperature. The received signal is processed using spectral analysis algorithms to identify specific spectral behaviors associated with common contaminants, such as heavy metals and volatile organic compounds. The results demonstrate that the system is a viable alternative for real-time water quality monitoring, with potential applications in industries, research laboratories, and environmental monitoring. This work contributes to the development of sustainable technological tools for water resource management and environmental preservation, offering an innovative approach based on UV optics and spectroscopy for contaminant detection.
eu_rights_str_mv openAccess
format bachelorThesis
id UNACH_7c40712103305b8b23ae74b93e2f906a
identifier_str_mv López L., Carlos D. (2024). Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV). (Tesis de grado). Universidad Nacional de Chimborazo. Riobamba, Ecuador.
UNACH-EC-FI-ITEL
instacron_str UNACH
institution UNACH
instname_str Universidad Nacional de Chimborazo
language spa
network_acronym_str UNACH
network_name_str Repositorio Universidad Nacional de Chimborazo
oai_identifier_str oai:localhost:51000/14472
publishDate 2025
publisher.none.fl_str_mv Riobamba
reponame_str Repositorio Universidad Nacional de Chimborazo
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazo
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).López Lucio, Carlos DanielEspectrometríaContaminantes de aguaInstrumentación portátilTransmisor-receptor.This work presents the design of a submersible optical system for the transmission and reception of signals in the ultraviolet range (200 nm to 400 nm), aimed at identifying contaminants in experimental water samples. The system seeks to provide an efficient and accurate tool for detecting harmful substances by analyzing the spectral interactions of UV light with contaminants present in water. The system design includes two main modules: an optical transmitter, which emits UV light signals within a controlled range, and an optical receiver, responsible for capturing and analyzing the spectral response of the aquatic medium. The transmitter is based on ultraviolet light sources calibrated to operate within the specified range, while the receiver employs highly sensitive and selective optical sensors capable of recording changes in the intensity and wavelength of light after interacting with contaminants. Additionally, a robust submersible structure was designed to withstand adverse conditions, ensuring reliable operation in aquatic environments with varying levels of turbidity and temperature. The received signal is processed using spectral analysis algorithms to identify specific spectral behaviors associated with common contaminants, such as heavy metals and volatile organic compounds. The results demonstrate that the system is a viable alternative for real-time water quality monitoring, with potential applications in industries, research laboratories, and environmental monitoring. This work contributes to the development of sustainable technological tools for water resource management and environmental preservation, offering an innovative approach based on UV optics and spectroscopy for contaminant detection.En el presente trabajo desarrolla el diseño de un sistema óptico sumergible para la transmisión y recepción de señales en el rango ultravioleta (200 nm a 400 nm) con el objetivo de identificar contaminantes en agua de experimentación. Este sistema busca ofrecer una herramienta eficiente y precisa para detectar sustancias nocivas mediante el análisis espectral de las interacciones ópticas de la luz UV con los contaminantes presentes en el agua. El diseño del sistema contempla dos módulos principales: un transmisor óptico, que emite señales de luz UV en un rango controlado, y un receptor óptico, encargado de captar y analizar la respuesta espectral del medio acuático. El transmisor se basa en fuentes de luz ultravioleta calibradas para operar en el rango especificado, mientras que el receptor emplea sensores ópticos de alta sensibilidad y selectividad, capaces de registrar los cambios en la intensidad y longitud de onda de la luz tras su interacción con los contaminantes. Además, se diseñó una estructura sumergible resistente a condiciones adversas, asegurando la operación en entornos acuáticos con distintos niveles de turbidez y temperatura. La señal recibida es procesada mediante algoritmos de análisis espectral para identificar los comportamientos espectrales que caracterizan a los contaminantes más comunes, como metales pesados y compuestos orgánicos volátiles. Los resultados demuestran que el sistema es una alternativa viable para monitorear la calidad del agua en tiempo real, con aplicaciones potenciales en industrias, laboratorios de investigación y monitoreo ambiental. Este trabajo contribuye al desarrollo de herramientas tecnológicas sostenibles para la gestión de recursos hídricos y la preservación ambiental, ofreciendo un enfoque innovador basado en óptica y espectroscopia UV para la detección de contaminantes.UNACH, Ecuador.RiobambaEscudero Villa, Pedro Fernando2025-01-07T20:14:22Z2025-01-07T20:14:22Z2025-01-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis70 páginas.López L., Carlos D. (2024). Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV). (Tesis de grado). Universidad Nacional de Chimborazo. Riobamba, Ecuador.UNACH-EC-FI-ITELhttp://dspace.unach.edu.ec/handle/51000/14472spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Chimborazoinstname:Universidad Nacional de Chimborazoinstacron:UNACH2025-01-23T09:19:39Zoai:localhost:51000/14472Institucionalhttp://dspace.unach.edu.ec/Universidad públicahttps://www.unach.edu.ec/http://dspace.unach.edu.ec/oai.Ecuador...opendoar:02025-01-23T09:19:39Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazofalse
spellingShingle Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
López Lucio, Carlos Daniel
Espectrometría
Contaminantes de agua
Instrumentación portátil
Transmisor-receptor.
status_str publishedVersion
title Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
title_full Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
title_fullStr Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
title_full_unstemmed Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
title_short Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
title_sort Diseño de un sistema de transmisión-recepción óptico sumergible para identificar contaminantes en agua de experimentación en el rango de 200nm a 400nm (UV).
topic Espectrometría
Contaminantes de agua
Instrumentación portátil
Transmisor-receptor.
url http://dspace.unach.edu.ec/handle/51000/14472