Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato

This research evaluates the operational performance of the Ambato Wastewater Treatment Plant (WWTP) with the aim of analyzing the efficiency of contaminant removal and proposing technical improvements to optimize treatment, especially with regard to nutrient removal. The study was developed using an...

Descrición completa

Gardado en:
Detalles Bibliográficos
Autor Principal: López Olmedo, Dany Diogo (author)
Formato: bachelorThesis
Idioma:spa
Publicado: 2026
Subjects:
Acceso en liña:http://dspace.unach.edu.ec/handle/51000/16527
Tags: Engadir etiqueta
Sen Etiquetas, Sexa o primeiro en etiquetar este rexistro!
_version_ 1859016532919582720
author López Olmedo, Dany Diogo
author_facet López Olmedo, Dany Diogo
author_role author
collection Repositorio Universidad Nacional de Chimborazo
dc.contributor.none.fl_str_mv Ríos García, Iván Alfredo
dc.creator.none.fl_str_mv López Olmedo, Dany Diogo
dc.date.none.fl_str_mv 2026-02-10T17:29:26Z
2026-02-10T17:29:38Z
2026-02-10T17:29:26Z
2026-02-10T17:29:38Z
2026-02-10
dc.format.none.fl_str_mv 108 páginas
dc.identifier.none.fl_str_mv López O., Dany D. (2026) Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato. (Tesis de grado). Universidad Nacional de Chimborazo. Riobamba, Ecuador.
UNACH-EC-FI-IAMB
http://dspace.unach.edu.ec/handle/51000/16527
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Riobamba
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Chimborazo
instname:Universidad Nacional de Chimborazo
instacron:UNACH
dc.subject.none.fl_str_mv Tratamiento de aguas
PTAR Ambato
Eficiencia operativa
Rediseño técnico
dc.title.none.fl_str_mv Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description This research evaluates the operational performance of the Ambato Wastewater Treatment Plant (WWTP) with the aim of analyzing the efficiency of contaminant removal and proposing technical improvements to optimize treatment, especially with regard to nutrient removal. The study was developed using an experimental-analytical approach, structured in phases that included the characterization of the influent and effluent, the individual evaluation of the unit operations, and the proposal for the optimization of the biological system. The characterization of the wastewater was based on spot sampling and the analysis of monthly information for the year 2024, provided by the operating company EP-EMAPA-A. The results show that the WWTP performs adequately in removing organic matter, suspended solids, and pathogenic microorganisms, as reflected in high BOD₅, COD, and turbidity efficiencies, as well as effective disinfection. However, limitations were identified in the removal of total Kjeldahl nitrogen and total phosphorus, with values that in certain periods exceed the limits established in current environmental regulations. The analysis of the unit operations made it possible to determine that these deficiencies are associated with the configuration of the biological reactor, which operates only under aerobic conditions, without stages that allow denitrification. Based on these results, a technical redesign of the biological system was developed, considering the incorporation of an anoxic volume as a viable alternative to improve nutrient removal under current operating conditions. Finally, the proposal seeks to strengthen treatment efficiency, ensure regulatory compliance, and ensure the operational sustainability of the WWTP in the face of future growth in flow and pollutant load.
eu_rights_str_mv openAccess
format bachelorThesis
id UNACH_9ecd61d26d35c2d1a94b208151e6ffdf
identifier_str_mv López O., Dany D. (2026) Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato. (Tesis de grado). Universidad Nacional de Chimborazo. Riobamba, Ecuador.
UNACH-EC-FI-IAMB
instacron_str UNACH
institution UNACH
instname_str Universidad Nacional de Chimborazo
language spa
network_acronym_str UNACH
network_name_str Repositorio Universidad Nacional de Chimborazo
oai_identifier_str oai:localhost:51000/16527
publishDate 2026
publisher.none.fl_str_mv Riobamba
reponame_str Repositorio Universidad Nacional de Chimborazo
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazo
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón AmbatoLópez Olmedo, Dany DiogoTratamiento de aguasPTAR AmbatoEficiencia operativaRediseño técnicoThis research evaluates the operational performance of the Ambato Wastewater Treatment Plant (WWTP) with the aim of analyzing the efficiency of contaminant removal and proposing technical improvements to optimize treatment, especially with regard to nutrient removal. The study was developed using an experimental-analytical approach, structured in phases that included the characterization of the influent and effluent, the individual evaluation of the unit operations, and the proposal for the optimization of the biological system. The characterization of the wastewater was based on spot sampling and the analysis of monthly information for the year 2024, provided by the operating company EP-EMAPA-A. The results show that the WWTP performs adequately in removing organic matter, suspended solids, and pathogenic microorganisms, as reflected in high BOD₅, COD, and turbidity efficiencies, as well as effective disinfection. However, limitations were identified in the removal of total Kjeldahl nitrogen and total phosphorus, with values that in certain periods exceed the limits established in current environmental regulations. The analysis of the unit operations made it possible to determine that these deficiencies are associated with the configuration of the biological reactor, which operates only under aerobic conditions, without stages that allow denitrification. Based on these results, a technical redesign of the biological system was developed, considering the incorporation of an anoxic volume as a viable alternative to improve nutrient removal under current operating conditions. Finally, the proposal seeks to strengthen treatment efficiency, ensure regulatory compliance, and ensure the operational sustainability of the WWTP in the face of future growth in flow and pollutant load.La presente investigación evalúa el desempeño operativo de la Planta de Tratamiento de Aguas Residuales (PTAR) Ambato, con el objetivo de analizar la eficiencia de remoción de contaminantes y proponer mejoras técnicas que permitan optimizar el tratamiento, especialmente en lo referente a la eliminación de nutrientes. El estudio se desarrolló mediante un enfoque experimental–analítico, estructurado en fases que incluyeron la caracterización del afluente y efluente, la evaluación individual de las operaciones unitarias y el planteamiento de una propuesta de optimización del sistema biológico. La caracterización del agua residual se realizó a partir de muestreos puntuales y del análisis de información mensual correspondiente al año 2024, proporcionada por la empresa operadora EP-EMAPA-A. Los resultados evidencian un adecuado desempeño de la PTAR en la remoción de materia orgánica, sólidos suspendidos y microorganismos patógenos, reflejado en altas eficiencias de DBO₅, DQO y turbidez, así como en una desinfección eficaz. No obstante, se identificaron limitaciones en la remoción de nitrógeno total Kjeldahl y fósforo total, con valores que en ciertos periodos superan los límites establecidos en la normativa ambiental vigente. El análisis de las operaciones unitarias permitió determinar que estas deficiencias están asociadas a la configuración del reactor biológico, el cual opera únicamente bajo condiciones aerobias, sin etapas que permitan la desnitrificación. En función de estos resultados, se desarrolló un rediseño técnico del sistema biológico, considerando la incorporación de un volumen anóxico como alternativa viable para mejorar la remoción de nutrientes bajo las condiciones actuales de operación. Finalmente, la propuesta busca fortalecer la eficiencia del tratamiento, garantizar el cumplimiento normativo y asegurar la sostenibilidad operativa de la PTAR frente al crecimiento futuro del caudal y la carga contaminanteUNACH, Ecuador.RiobambaRíos García, Iván Alfredo2026-02-10T17:29:26Z2026-02-10T17:29:38Z2026-02-10T17:29:26Z2026-02-10T17:29:38Z2026-02-10info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis108 páginasLópez O., Dany D. (2026) Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato. (Tesis de grado). Universidad Nacional de Chimborazo. Riobamba, Ecuador.UNACH-EC-FI-IAMBhttp://dspace.unach.edu.ec/handle/51000/16527spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Chimborazoinstname:Universidad Nacional de Chimborazoinstacron:UNACH2026-02-10T17:29:39Zoai:localhost:51000/16527Institucionalhttp://dspace.unach.edu.ec/Universidad públicahttps://www.unach.edu.ec/http://dspace.unach.edu.ec/oai.Ecuador...opendoar:02026-02-10T17:29:39Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazofalse
spellingShingle Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
López Olmedo, Dany Diogo
Tratamiento de aguas
PTAR Ambato
Eficiencia operativa
Rediseño técnico
status_str publishedVersion
title Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
title_full Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
title_fullStr Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
title_full_unstemmed Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
title_short Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
title_sort Optimización de las operaciones unitarias de la planta de tratamiento de aguas residuales “Ambato” ubicada en el sector las Viñas en el cantón Ambato
topic Tratamiento de aguas
PTAR Ambato
Eficiencia operativa
Rediseño técnico
url http://dspace.unach.edu.ec/handle/51000/16527