Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga

The main objective of this research project was to contribute to the development of the emergency and contingency plan proposal under the guidelines of NFPA 1600 for the company Agrinag, for which the preparation of the Emergency Plan was carried out under the Corps format. Santo Domingo Fire Depart...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Molina Arias, Jeferson Mauricio (author)
Formato: bachelorThesis
Idioma:spa
Publicado em: 2023
Assuntos:
Acesso em linha:http://dspace.unach.edu.ec/handle/51000/11758
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
_version_ 1862821859250143232
author Molina Arias, Jeferson Mauricio
author_facet Molina Arias, Jeferson Mauricio
author_role author
collection Repositorio Universidad Nacional de Chimborazo
dc.contributor.none.fl_str_mv Bejarano Naula, Carlos Mesías
dc.creator.none.fl_str_mv Molina Arias, Jeferson Mauricio
dc.date.none.fl_str_mv 2023-11-09T22:03:18Z
2023-11-09T22:03:18Z
2023-11-09
dc.format.none.fl_str_mv 176 páginas
dc.identifier.none.fl_str_mv UNACH- FI-IAGRI
http://dspace.unach.edu.ec/handle/51000/11758
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Riobamba, Universidad Nacional de Chimborazo
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Chimborazo
instname:Universidad Nacional de Chimborazo
instacron:UNACH
dc.subject.none.fl_str_mv NFPA
MESERI
Baker
Plan de emergencia y contingencia
Incendios.
dc.title.none.fl_str_mv Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The main objective of this research project was to contribute to the development of the emergency and contingency plan proposal under the guidelines of NFPA 1600 for the company Agrinag, for which the preparation of the Emergency Plan was carried out under the Corps format. Santo Domingo Fire Department, where fire and explosion risks were identified by applying specific methodologies such as the NFPA (National Fire Protection Association), MESERI (Simplified Method of Fire Risk Assessment) and Baker methodology (explosion). The research approach is descriptive, it will allow us to analyze the different fire risk factors existing in the different facilities of the Agrinag company, the research design is non-experimental, the population is 120 workers, men and women. Based on the risk values, two MEDIUM RISKS were obtained in the NFPA matrix in two specific areas (Raw Materials Warehouse and Hazardous Waste Warehouse). With the MESERI method the result was IMPORTANT RISK of 4.87, with the Baker methodology from 6.9 meters for eardrum rupture no affectation was seen, while for death from pulmonary hemorrhage from quantities at 0.63 meters No percentages of affected people are observed. Finally, through the application of fire and explosion risk assessments in the Agrinag company, the emergency and contingency plan proposal is left in compliance with the respective processes for its validation and approval.
eu_rights_str_mv openAccess
format bachelorThesis
id UNACH_ad0e4bfdc6831d72a7e543efca09c85a
identifier_str_mv UNACH- FI-IAGRI
instacron_str UNACH
institution UNACH
instname_str Universidad Nacional de Chimborazo
language spa
network_acronym_str UNACH
network_name_str Repositorio Universidad Nacional de Chimborazo
oai_identifier_str oai:localhost:51000/11758
publishDate 2023
publisher.none.fl_str_mv Riobamba, Universidad Nacional de Chimborazo
reponame_str Repositorio Universidad Nacional de Chimborazo
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazo
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de LatacungaMolina Arias, Jeferson MauricioNFPAMESERIBakerPlan de emergencia y contingenciaIncendios.The main objective of this research project was to contribute to the development of the emergency and contingency plan proposal under the guidelines of NFPA 1600 for the company Agrinag, for which the preparation of the Emergency Plan was carried out under the Corps format. Santo Domingo Fire Department, where fire and explosion risks were identified by applying specific methodologies such as the NFPA (National Fire Protection Association), MESERI (Simplified Method of Fire Risk Assessment) and Baker methodology (explosion). The research approach is descriptive, it will allow us to analyze the different fire risk factors existing in the different facilities of the Agrinag company, the research design is non-experimental, the population is 120 workers, men and women. Based on the risk values, two MEDIUM RISKS were obtained in the NFPA matrix in two specific areas (Raw Materials Warehouse and Hazardous Waste Warehouse). With the MESERI method the result was IMPORTANT RISK of 4.87, with the Baker methodology from 6.9 meters for eardrum rupture no affectation was seen, while for death from pulmonary hemorrhage from quantities at 0.63 meters No percentages of affected people are observed. Finally, through the application of fire and explosion risk assessments in the Agrinag company, the emergency and contingency plan proposal is left in compliance with the respective processes for its validation and approval.El presente proyecto de investigación tuvo como objetivo principal contribuir al desarrollo de la propuesta del plan de emergencia y contingencia bajo los lineamiento de la NFPA 1600 para la empresa Agrinag, por lo cual se realizó, la elaboración del Plan de Emergencia bajo el formato del Cuerpo de Bomberos de Santo Domingo, donde se identificó los riesgos de incendios y explosión aplicando metodologías específicas como la NFPA (Asociación Nacional de Protección contra el Fuego), MESERI (Método Simplificado de Evaluación del Riesgo de Incendio) y metodología Baker (explosión). El enfoque de la investigación es descriptivo, nos permitirá analizar los diferentes factores de riesgo de incendios existentes en las diferentes instalaciones de la empresa Agrinag, el diseño de la investigación es no experimental, la población es de 120 trabajadores entre hombres y mujeres. Sobre la base de los valores de riesgo, en la matriz NFPA se obtuvo dos RIESGOS MEDIOS en dos áreas específicas (Bodega de Materia Prima y Bodega de Desechos Peligrosos). Con el método MESERI dio como resultado RIESGO IMPORTANTE de 4,87, con la metodología Baker a partir de 6,9 metros para rotura de tímpano no se visualiza afectación alguna, mientras por muerte de hemorragia pulmonar a partir de cantidades a 0,63 metros no se observa porcentajes de personas afectadas. Finalmente, Mediante la aplicación de evaluaciones de riesgos de incendios y explosión en la empresa Agrinag, se deja la propuesta del plan de emergencia y contingencia cumpliendo con los procesos respectivos para su validación y aprobación.UNACH, EcuadorRiobamba, Universidad Nacional de ChimborazoBejarano Naula, Carlos Mesías2023-11-09T22:03:18Z2023-11-09T22:03:18Z2023-11-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis176 páginasUNACH- FI-IAGRIhttp://dspace.unach.edu.ec/handle/51000/11758spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Chimborazoinstname:Universidad Nacional de Chimborazoinstacron:UNACH2023-11-23T08:07:26Zoai:localhost:51000/11758Institucionalhttp://dspace.unach.edu.ec/Universidad públicahttps://www.unach.edu.ec/http://dspace.unach.edu.ec/oai.Ecuador...opendoar:02023-11-23T08:07:26Repositorio Universidad Nacional de Chimborazo - Universidad Nacional de Chimborazofalse
spellingShingle Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
Molina Arias, Jeferson Mauricio
NFPA
MESERI
Baker
Plan de emergencia y contingencia
Incendios.
status_str publishedVersion
title Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
title_full Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
title_fullStr Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
title_full_unstemmed Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
title_short Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
title_sort Elaboración de un plan de emergencia bajo la estructura nfpa 1600 para la empresa Agrinag ubicada en la Ciudad de Latacunga
topic NFPA
MESERI
Baker
Plan de emergencia y contingencia
Incendios.
url http://dspace.unach.edu.ec/handle/51000/11758