Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo
This study addresses the design and simulation of an ankle-foot orthosis (AFO), also known as an anti-equinus splint, using CAD/CAE software, with the aim of improving the treatment of foot and ankle equinus deformity. Equinus deformities, characterized by excessive plantar flexion, are common in pa...
Guardat en:
| Autor principal: | |
|---|---|
| Format: | bachelorThesis |
| Idioma: | spa |
| Publicat: |
2025
|
| Matèries: | |
| Accés en línia: | https://dspace.uniandes.edu.ec/handle/123456789/19221 |
| Etiquetes: |
Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
|
| _version_ | 1855202486580674560 |
|---|---|
| author | Viteri Jaramillo, Analhi Diamela |
| author_facet | Viteri Jaramillo, Analhi Diamela |
| author_role | author |
| collection | Repositorio Universidad Regional Autónoma de los Andes |
| dc.contributor.none.fl_str_mv | Pineda Silva, Giovanny Vinicio |
| dc.creator.none.fl_str_mv | Viteri Jaramillo, Analhi Diamela |
| dc.date.none.fl_str_mv | 2025-05-07T20:43:42Z 2025-05-07T20:43:42Z 2025-05 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | UA-BIO-EAC-004-2025 https://dspace.uniandes.edu.ec/handle/123456789/19221 |
| dc.language.none.fl_str_mv | spa |
| dc.rights.none.fl_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Regional Autónoma de los Andes instname:Universidad Regional Autónoma de los Andes instacron:UNIANDES |
| dc.subject.none.fl_str_mv | FÉRULA ANTIEQUINO ABS PLA DEFORMACIÓN |
| dc.title.none.fl_str_mv | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | This study addresses the design and simulation of an ankle-foot orthosis (AFO), also known as an anti-equinus splint, using CAD/CAE software, with the aim of improving the treatment of foot and ankle equinus deformity. Equinus deformities, characterized by excessive plantar flexion, are common in patients with muscle, nerve, or tendon injuries and can cause difficulties in walking. The use of conventional anti-equinus splints has limitations due to their standardized design, which can lead to discomfort and ineffective immobilization. The objective of the study was to design an anti-equinus splint using virtual models of feet and ankles based on anthropometric data from the Latin American population, to ensure precise fit and improve functionality. The methodology employed was quantitative, based on the use of CAD software to create a detailed model of the splint and CAE software to simulate its behavior under different loading conditions. The polymeric materials used were PLA (Polylactic Acid) and ABS (Acrylonitrile Butadiene Styrene), subjected to different loads to evaluate their mechanical stress, deformation, and displacement. The results indicated that both materials have similar capabilities to withstand stress, but PLA exhibited less deformation and displacement compared to ABS, suggesting it is more suitable for applications requiring greater dimensional stability. Under the maximum load of 200 kg, the displacement of PLA was 3,509 μm, while that of ABS was 6,182 μm. Regarding deformation, PLA showed a rate of 5,996 × 10⁻⁵ %, significantly lower than that of ABS 1,051 × 10⁻⁴ %. In conclusion, the use of CAD/CAE software allows for the creation of customized splints that better fit the patient's anatomy, improving the comfort and effectiveness of treatment. This approach represents an advance in the design of orthopedic devices and a well-founded basis for the development of future research to optimize their use. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UNIANDES_e4cf78c28d7d98934a67ceb267b5e72a |
| identifier_str_mv | UA-BIO-EAC-004-2025 |
| instacron_str | UNIANDES |
| institution | UNIANDES |
| instname_str | Universidad Regional Autónoma de los Andes |
| language | spa |
| network_acronym_str | UNIANDES |
| network_name_str | Repositorio Universidad Regional Autónoma de los Andes |
| oai_identifier_str | oai:dspace.uniandes.edu.ec:123456789/19221 |
| publishDate | 2025 |
| reponame_str | Repositorio Universidad Regional Autónoma de los Andes |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Regional Autónoma de los Andes - Universidad Regional Autónoma de los Andes |
| repository_id_str | 455 |
| rights_invalid_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ |
| spelling | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobilloViteri Jaramillo, Analhi DiamelaFÉRULA ANTIEQUINOABSPLADEFORMACIÓNThis study addresses the design and simulation of an ankle-foot orthosis (AFO), also known as an anti-equinus splint, using CAD/CAE software, with the aim of improving the treatment of foot and ankle equinus deformity. Equinus deformities, characterized by excessive plantar flexion, are common in patients with muscle, nerve, or tendon injuries and can cause difficulties in walking. The use of conventional anti-equinus splints has limitations due to their standardized design, which can lead to discomfort and ineffective immobilization. The objective of the study was to design an anti-equinus splint using virtual models of feet and ankles based on anthropometric data from the Latin American population, to ensure precise fit and improve functionality. The methodology employed was quantitative, based on the use of CAD software to create a detailed model of the splint and CAE software to simulate its behavior under different loading conditions. The polymeric materials used were PLA (Polylactic Acid) and ABS (Acrylonitrile Butadiene Styrene), subjected to different loads to evaluate their mechanical stress, deformation, and displacement. The results indicated that both materials have similar capabilities to withstand stress, but PLA exhibited less deformation and displacement compared to ABS, suggesting it is more suitable for applications requiring greater dimensional stability. Under the maximum load of 200 kg, the displacement of PLA was 3,509 μm, while that of ABS was 6,182 μm. Regarding deformation, PLA showed a rate of 5,996 × 10⁻⁵ %, significantly lower than that of ABS 1,051 × 10⁻⁴ %. In conclusion, the use of CAD/CAE software allows for the creation of customized splints that better fit the patient's anatomy, improving the comfort and effectiveness of treatment. This approach represents an advance in the design of orthopedic devices and a well-founded basis for the development of future research to optimize their use.El presente estudio aborda el diseño y simulación de una órtesis tobillo-pie (AFO) conocida también como férula antiequino, mediante el uso de software CAD/CAE, con el objetivo de mejorar el tratamiento de la deformidad en equino de pie y tobillo. Está es caracterizada por una flexión plantar excesiva, son comunes en pacientes con lesiones musculares, nerviosas o tendinosas y pueden causar dificultades al caminar. El uso de férulas antiequino convencionales presenta limitaciones debido a su diseño estandarizado, lo que puede generar incomodidad y una inmovilización ineficaz. El objetivo del estudio fue diseñar una férula antiequino utilizando modelos virtuales de pies y tobillos basados en datos antropométricos de la población latinoamericana, para garantizar un ajuste preciso y mejorar la funcionalidad. La metodología empleada fue cuantitativa, basada en el uso de software CAD para crear un modelo detallado de la férula y software CAE para simular su comportamiento bajo diferentes condiciones de carga. Los materiales poliméricos utilizados fueron PLA (Ácido poliláctico) y ABS (Acrilonitrilo butadieno estireno), sometidos a diferentes cargas para evaluar su esfuerzo mecánico, deformación y desplazamiento. Los resultados indicaron que ambos materiales tienen capacidades similares para soportar esfuerzos, pero el PLA presentó una menor deformación y desplazamiento en comparación con el ABS, lo que sugiere que es más adecuado para aplicaciones que requieren mayor estabilidad dimensional. Bajo la máxima carga de 200 kg, el desplazamiento del PLA fue de 3,509 μm, mientras que el del ABS fue de 6,182 μm. En cuanto a la deformación, el PLA mostró una tasa de 5,996 × 10⁻⁵ %, significativamente menor que la del ABS 1,051 × 10⁻⁴ %. En conclusión, el uso de software CAD/CAE permite la creación de férulas personalizadas que se ajustan mejor a la anatomía del paciente, mejorando la comodidad y eficacia del tratamiento. Este enfoque representa un avance en el diseño de dispositivos ortopédicos y una base fundamentada para el desarrollo de futuras investigaciones, que permitan optimizar su uso.Pineda Silva, Giovanny Vinicio2025-05-07T20:43:42Z2025-05-07T20:43:42Z2025-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfUA-BIO-EAC-004-2025https://dspace.uniandes.edu.ec/handle/123456789/19221spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Regional Autónoma de los Andesinstname:Universidad Regional Autónoma de los Andesinstacron:UNIANDES2025-05-07T20:43:43Zoai:dspace.uniandes.edu.ec:123456789/19221Institucionalhttps://dspace.uniandes.edu.ec/Institución privadahttps://www.uniandes.edu.ec/https://dspace.uniandes.edu.ec/oai.Ecuador...opendoar:4552026-01-24T12:27:53.754083Repositorio Universidad Regional Autónoma de los Andes - Universidad Regional Autónoma de los Andestrue |
| spellingShingle | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo Viteri Jaramillo, Analhi Diamela FÉRULA ANTIEQUINO ABS PLA DEFORMACIÓN |
| status_str | publishedVersion |
| title | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| title_full | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| title_fullStr | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| title_full_unstemmed | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| title_short | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| title_sort | Diseño y simulación de una férula antiequino (afo) en pla y abs mediante software cad/cae aplicado en la deformidad en equino de pie y tobillo |
| topic | FÉRULA ANTIEQUINO ABS PLA DEFORMACIÓN |
| url | https://dspace.uniandes.edu.ec/handle/123456789/19221 |