Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.

This present research based on the study, Analysis and Evaluation of the electric conditioning equipment of X ray and ultrasound of the Isidro Ayora Hospital, considering all referring to: electrical power, canalization, protection, control, grounding and physical space required. As these equipment’...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
מחבר ראשי: Álvarez Enríquez, Oswaldo Francisco (author)
מחברים אחרים: Pacheco Ludeña, Cruzkaya Del Rosario (author)
פורמט: bachelorThesis
שפה:spa
יצא לאור: 2012
נושאים:
גישה מקוונת:http://dspace.unl.edu.ec/jspui/handle/123456789/12295
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1857832992341229568
author Álvarez Enríquez, Oswaldo Francisco
author2 Pacheco Ludeña, Cruzkaya Del Rosario
author2_role author
author_facet Álvarez Enríquez, Oswaldo Francisco
Pacheco Ludeña, Cruzkaya Del Rosario
author_role author
collection Repositorio Universidad Nacional de Loja
dc.contributor.none.fl_str_mv Orellana Villavicencio, Diego Vinicio
dc.creator.none.fl_str_mv Álvarez Enríquez, Oswaldo Francisco
Pacheco Ludeña, Cruzkaya Del Rosario
dc.date.none.fl_str_mv 2012
2016-05-11T21:34:05Z
2016-05-11T21:34:05Z
dc.format.none.fl_str_mv 196 p.
application/pdf
dc.identifier.none.fl_str_mv http://dspace.unl.edu.ec/jspui/handle/123456789/12295
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Loja
instname:Universidad Nacional de Loja
instacron:UNL
dc.subject.none.fl_str_mv <ACONDICIONAMIENTO ELÉCTRICO><ALIMENTACIÓN ELÉCTRICA><PROTECCIÓN><EQUIPOS MÉDICOS>
dc.title.none.fl_str_mv Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description This present research based on the study, Analysis and Evaluation of the electric conditioning equipment of X ray and ultrasound of the Isidro Ayora Hospital, considering all referring to: electrical power, canalization, protection, control, grounding and physical space required. As these equipment’s have lots of quantities of electronics elements, they are have taken all the parameters of electric energy, such as fall of tension, super voltage, flicker, harmonics of the effects that they produce in it. The procedure was performed and development in this present research and it consist in realize a study about actual on the conditioning current that the Isidro Ayora Hospital imaging area. Where we collect all the technical data required for: transformers, plate, conductors’ types of canalization, data breakers, control elements, grounding and physical space used so like electrical data of the plate of the equipment on study. Also we realize measure of quality of electrical energy with a FLUKE 1743, giving us important data for the Analysis, the some that permit us to Know the factual of the electrical power, that using such equipment. Then we realize on Analysis of the norms of electrical installation using as reference the National Electric Code (NEC) and other international standard such as: The World Health Organization (OMS), European Norm (EN), the International Electronically Commission (IEC), and International Organization for Standardization (ISO) among others. Finally, we proceeded to carry out the Evaluation of the type of conditioning that have the medical equipment and to establish the pertinent corrections those equipment that don’t get the standards established of electrical installation.
eu_rights_str_mv openAccess
format bachelorThesis
id UNL_55480851a573f42e13a15f57b6ec3d13
instacron_str UNL
institution UNL
instname_str Universidad Nacional de Loja
language spa
network_acronym_str UNL
network_name_str Repositorio Universidad Nacional de Loja
oai_identifier_str oai:dspace.unl.edu.ec:123456789/12295
publishDate 2012
reponame_str Repositorio Universidad Nacional de Loja
repository.mail.fl_str_mv *
repository.name.fl_str_mv Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.Álvarez Enríquez, Oswaldo FranciscoPacheco Ludeña, Cruzkaya Del Rosario<ACONDICIONAMIENTO ELÉCTRICO><ALIMENTACIÓN ELÉCTRICA><PROTECCIÓN><EQUIPOS MÉDICOS>This present research based on the study, Analysis and Evaluation of the electric conditioning equipment of X ray and ultrasound of the Isidro Ayora Hospital, considering all referring to: electrical power, canalization, protection, control, grounding and physical space required. As these equipment’s have lots of quantities of electronics elements, they are have taken all the parameters of electric energy, such as fall of tension, super voltage, flicker, harmonics of the effects that they produce in it. The procedure was performed and development in this present research and it consist in realize a study about actual on the conditioning current that the Isidro Ayora Hospital imaging area. Where we collect all the technical data required for: transformers, plate, conductors’ types of canalization, data breakers, control elements, grounding and physical space used so like electrical data of the plate of the equipment on study. Also we realize measure of quality of electrical energy with a FLUKE 1743, giving us important data for the Analysis, the some that permit us to Know the factual of the electrical power, that using such equipment. Then we realize on Analysis of the norms of electrical installation using as reference the National Electric Code (NEC) and other international standard such as: The World Health Organization (OMS), European Norm (EN), the International Electronically Commission (IEC), and International Organization for Standardization (ISO) among others. Finally, we proceeded to carry out the Evaluation of the type of conditioning that have the medical equipment and to establish the pertinent corrections those equipment that don’t get the standards established of electrical installation.El presente trabajo de tesis se basa en el estudio, análisis y evaluación del acondicionamiento eléctrico que tienen los equipos médicos de rayos X y de ultrasonido del Hospital Isidro Ayora. Considerando de esta manera todo lo referente a: alimentación eléctrica, canalización, protección, control, puesta a tierra y espacio físico requeridos. Como estos equipos poseen gran cantidad de elementos electrónicos, se ha tomado en cuenta todos los parámetros de calidad de energía eléctrica, tales como: caídas de tensión, sobretensiones, flicker (variación rápida y cíclica del voltaje), armónicos y los efectos que estos producen en el mismo. El procedimiento que se realizó para el desarrollo del trabajo consistió en realizar un estudio sobre el acondicionamiento actual que tiene el área de imagenología del Hospital, en donde se recogieron todos los datos técnicos requeridos, de: placas de transformadores, conductores, tipos de canalización, datos de breakers, elementos de control, puestas a tierra y espacio físico utilizado, así como datos eléctricos de placa de los equipos en estudio. También se efectuó mediciones de calidad de energía eléctrica con un FLUKE 1743, arrojando datos importantes para el análisis, los mismos que nos permitieron saber el estado actual de la energía eléctrica que utilizan dichos equipos. Luego se realizó un análisis con respecto a las normas de instalación eléctrica, utilizando como referencia el Código Eléctrico Nacional (CEN) y otras normas internacionales como: la Organización Mundial de la Salud (OMS), la Norma Europea (EN), la Comisión Electrotécnica Internacional (IEC), la Organización Internacional de Normalización (ISO), entre otras. Por último se procedió a realizar la evaluación del tipo de acondicionamiento que tienen los equipos médicos y a establecer las correcciones pertinentes a aquellos equipos que no cumplen con las normas de instalación eléctrica ya establecidas.Orellana Villavicencio, Diego Vinicio2016-05-11T21:34:05Z2016-05-11T21:34:05Z2012info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis196 p.application/pdfhttp://dspace.unl.edu.ec/jspui/handle/123456789/12295spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T14:27:36Zoai:dspace.unl.edu.ec:123456789/12295Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T14:27:36falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T14:27:36Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse
spellingShingle Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
Álvarez Enríquez, Oswaldo Francisco
<ACONDICIONAMIENTO ELÉCTRICO><ALIMENTACIÓN ELÉCTRICA><PROTECCIÓN><EQUIPOS MÉDICOS>
status_str publishedVersion
title Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
title_full Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
title_fullStr Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
title_full_unstemmed Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
title_short Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
title_sort Estudio, análisis y evaluación del acondicionamiento eléctrico, de los equipos médicos del área de imagenología del Hospital Isidro Ayora de la ciudad de Loja.
topic <ACONDICIONAMIENTO ELÉCTRICO><ALIMENTACIÓN ELÉCTRICA><PROTECCIÓN><EQUIPOS MÉDICOS>
url http://dspace.unl.edu.ec/jspui/handle/123456789/12295