Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.

The present work develops a methodology to carry out measurements of electric power quality in low voltage, to program the network recording equipment, to install it, to export the data and to make calculations of the quality parameters of the product. For the calculation of these parameters an algo...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Curipoma Quizhpe, Galo Israel (author)
التنسيق: bachelorThesis
اللغة:spa
منشور في: 2017
الموضوعات:
الوصول للمادة أونلاين:http://dspace.unl.edu.ec/jspui/handle/123456789/19165
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
_version_ 1857833143256481792
author Curipoma Quizhpe, Galo Israel
author_facet Curipoma Quizhpe, Galo Israel
author_role author
collection Repositorio Universidad Nacional de Loja
dc.contributor.none.fl_str_mv Carrión González, Jorge Enrique
dc.creator.none.fl_str_mv Curipoma Quizhpe, Galo Israel
dc.date.none.fl_str_mv 2017-07-05T21:48:09Z
2017-07-05T21:48:09Z
2017
dc.format.none.fl_str_mv 85 p.
application/pdf
dc.identifier.none.fl_str_mv http://dspace.unl.edu.ec/jspui/handle/123456789/19165
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Loja
instname:Universidad Nacional de Loja
instacron:UNL
dc.subject.none.fl_str_mv <ANALIZADOR DE REDES FLUKE 1744><CALIDAD DEL SERVICIO EN BAJA TENSIÓN><PARÁMETROS DE CALIDAD DE ENERGÍA><CONELEC_004/01><NORMA IEEE 519>
dc.title.none.fl_str_mv Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The present work develops a methodology to carry out measurements of electric power quality in low voltage, to program the network recording equipment, to install it, to export the data and to make calculations of the quality parameters of the product. For the calculation of these parameters an algorithm was made that allows the extraction of the database and the calculation of automatic form. For this purpose national and international norms have been considered as well as bibliography and methodologies that are related to the thematic approach. The methodology is developed for different types of energy quality recorders: Fluke, Topas 1000 and PQBox 100, which are the most common in our environment. The algorithm developed is general and can be applied to different load registers, although the order in which the data is exported must be taken into account, a situation explained in detail in the present. To validate the research project is used the electrical network recorder equipment FLUKE 1744, which is available in the Faculty of Energy Industries and Non-Renewable Natural Resources of the National University of Loja, with which measurements were made on the transformer Three-phase 50 kVA N °. 18213, to provide electricity to the laboratory building. The measurements were carried out in a period of seven days with an interval of 10 minutes, according to the recommendations issued in Regulation No. CONELEC¬_004 / 01. The measurement records are used in the methodology developed by inserting in a dynamic spreadsheet, to evaluate the quality of the low voltage product automatically. Analyzing the results it is determined that they are favorable since all the quality parameters are within the limits allowed according to the Regulation, obtaining for Phase A the following results: the limit of the voltage level is of ± 10% being the value census - 1.3% (125.56 V- meets); Flicker severity level not greater than 1 p.u. (0.29 p.u.-meet); Harmonic distortion of voltage not exceeding 8% (1.74% - complies) and the limit of the power factor not greater than 0.92 (0.95-complies), voltage harmonics of the order 2 to 40 are within the limits Established. Similar analysis can be performed for phase B and C.
eu_rights_str_mv openAccess
format bachelorThesis
id UNL_7b25dfcdd180421fc367761cd1ffc5ed
instacron_str UNL
institution UNL
instname_str Universidad Nacional de Loja
language spa
network_acronym_str UNL
network_name_str Repositorio Universidad Nacional de Loja
oai_identifier_str oai:dspace.unl.edu.ec:123456789/19165
publishDate 2017
reponame_str Repositorio Universidad Nacional de Loja
repository.mail.fl_str_mv *
repository.name.fl_str_mv Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.Curipoma Quizhpe, Galo Israel<ANALIZADOR DE REDES FLUKE 1744><CALIDAD DEL SERVICIO EN BAJA TENSIÓN><PARÁMETROS DE CALIDAD DE ENERGÍA><CONELEC_004/01><NORMA IEEE 519>The present work develops a methodology to carry out measurements of electric power quality in low voltage, to program the network recording equipment, to install it, to export the data and to make calculations of the quality parameters of the product. For the calculation of these parameters an algorithm was made that allows the extraction of the database and the calculation of automatic form. For this purpose national and international norms have been considered as well as bibliography and methodologies that are related to the thematic approach. The methodology is developed for different types of energy quality recorders: Fluke, Topas 1000 and PQBox 100, which are the most common in our environment. The algorithm developed is general and can be applied to different load registers, although the order in which the data is exported must be taken into account, a situation explained in detail in the present. To validate the research project is used the electrical network recorder equipment FLUKE 1744, which is available in the Faculty of Energy Industries and Non-Renewable Natural Resources of the National University of Loja, with which measurements were made on the transformer Three-phase 50 kVA N °. 18213, to provide electricity to the laboratory building. The measurements were carried out in a period of seven days with an interval of 10 minutes, according to the recommendations issued in Regulation No. CONELEC¬_004 / 01. The measurement records are used in the methodology developed by inserting in a dynamic spreadsheet, to evaluate the quality of the low voltage product automatically. Analyzing the results it is determined that they are favorable since all the quality parameters are within the limits allowed according to the Regulation, obtaining for Phase A the following results: the limit of the voltage level is of ± 10% being the value census - 1.3% (125.56 V- meets); Flicker severity level not greater than 1 p.u. (0.29 p.u.-meet); Harmonic distortion of voltage not exceeding 8% (1.74% - complies) and the limit of the power factor not greater than 0.92 (0.95-complies), voltage harmonics of the order 2 to 40 are within the limits Established. Similar analysis can be performed for phase B and C.El presente trabajo desarrolla una metodología para realizar mediciones de calidad de energía eléctrica en baja tensión, programar el equipo registrador de redes, instalarlo, exportar los datos y efectuar cálculos de los parámetros de calidad del producto. Para el cálculo de estos parámetros se realizó un algoritmo que permite la extracción de la base de datos y el cálculo de forma automática. Para este efecto se han considerado normas nacionales e internacionales como también bibliografía y metodologías que tienen relación con la temática abordada. La metodología es desarrollada para diferentes tipos de registradores de calidad de energía: Fluke, Topas 1000 y PQBox 100, que son los más comunes en nuestro medio. El algoritmo desarrollado es general y puede ser aplicado para distintos registradores de carga, aunque se debe tomar en cuenta el orden que se exportan los datos, situación explicada detalladamente en el presente. Para validar el proyecto de investigación se utiliza el equipo registrador de redes eléctricas FLUKE 1744, que está disponible en la Facultad de la Energía las Industrias y los Recursos Naturales no Renovables de la Universidad Nacional de Loja, con el que se realizaron mediciones en el transformador trifásico de 50 kVA N°. 18213, destinado a dotar de suministro eléctrico al edificio de laboratorios. Las mediciones se efectuaron en un periodo de siete días con intervalo de 10 minutos, de acuerdo a las recomendaciones emitidas en la Regulación No. CONELEC¬_004/01. Los registros de la medición se utilizan en la metodología desarrollada insertando en una hoja de cálculo dinámica, para evaluar la calidad del producto en baja tensión de forma automática. Analizando los resultados se determina que son favorables ya que todos los parámetros de calidad están dentro de los límites permitidos según la Regulación, obteniéndose para la Fase A los siguientes resultados: el límite del nivel de voltaje es de ±10% siendo el valor censado -1,3% (125,56 V- cumple); nivel de severidad de flicker no mayor al 1 p.u (0,29 p.u.-cumple); distorsión armónica de voltaje no superior a 8% (1.74 %- cumple) y el límite del factor de potencia no mayor a 0,92 (0,95-cumple), los armónicos de voltaje del orden 2 al 40 están dentro de los límites establecidos. Similar análisis se puede efectuar para la fase B y C.Carrión González, Jorge Enrique2017-07-05T21:48:09Z2017-07-05T21:48:09Z2017info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis85 p.application/pdfhttp://dspace.unl.edu.ec/jspui/handle/123456789/19165spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T17:18:42Zoai:dspace.unl.edu.ec:123456789/19165Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T17:18:42falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T17:18:42Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse
spellingShingle Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
Curipoma Quizhpe, Galo Israel
<ANALIZADOR DE REDES FLUKE 1744><CALIDAD DEL SERVICIO EN BAJA TENSIÓN><PARÁMETROS DE CALIDAD DE ENERGÍA><CONELEC_004/01><NORMA IEEE 519>
status_str publishedVersion
title Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
title_full Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
title_fullStr Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
title_full_unstemmed Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
title_short Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
title_sort Metodología para efectuar mediciones de calidad del servicio eléctrico en baja tensión.
topic <ANALIZADOR DE REDES FLUKE 1744><CALIDAD DEL SERVICIO EN BAJA TENSIÓN><PARÁMETROS DE CALIDAD DE ENERGÍA><CONELEC_004/01><NORMA IEEE 519>
url http://dspace.unl.edu.ec/jspui/handle/123456789/19165