Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga.
In the present research work is proposed to analyze the effect of temperature variation of the working fluid on the characteristic curves of a centrifugal pump of ½ Hp brand Pedrollo CPm130. In the development of the document, the methodology used for data acquisition is detailed, and information re...
שמור ב:
| מחבר ראשי: | |
|---|---|
| פורמט: | bachelorThesis |
| שפה: | spa |
| יצא לאור: |
2020
|
| נושאים: | |
| גישה מקוונת: | http://dspace.unl.edu.ec/jspui/handle/123456789/22952 |
| תגים: |
הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
|
| _version_ | 1857833009300897792 |
|---|---|
| author | Alvarado Alvarado, Victor Manuel |
| author_facet | Alvarado Alvarado, Victor Manuel |
| author_role | author |
| collection | Repositorio Universidad Nacional de Loja |
| dc.contributor.none.fl_str_mv | Tapia Peralta, Darwin Giovanny |
| dc.creator.none.fl_str_mv | Alvarado Alvarado, Victor Manuel |
| dc.date.none.fl_str_mv | 2020-01-08T20:47:15Z 2020-01-08T20:47:15Z 2020-01-08 |
| dc.format.none.fl_str_mv | 122 p. application/pdf |
| dc.identifier.none.fl_str_mv | http://dspace.unl.edu.ec/jspui/handle/123456789/22952 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Loja:Universidad Nacional de Loja |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Nacional de Loja instname:Universidad Nacional de Loja instacron:UNL |
| dc.subject.none.fl_str_mv | <VARIACIÓN DE TEMPERATURA><BOMBA CENTRÍFUGA><CURVAS DE BOMBA><MODELO EXPERIMENTAL><BOMBA PEDROLLO CPM 130> |
| dc.title.none.fl_str_mv | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | In the present research work is proposed to analyze the effect of temperature variation of the working fluid on the characteristic curves of a centrifugal pump of ½ Hp brand Pedrollo CPm130. In the development of the document, the methodology used for data acquisition is detailed, and information regarding the influence that the temperature of the fluid has on a centrifugal pump was systematized by means of books, magazines, articles, etc. Based on this information, the necessary components that the test bench should have were determined. A practice guide was prepared based on the institutional format of the National University of Loja (UNL) and standard ISO 9906:1999, which facilitated the acquisition of data by means of the record sheet prepared from the above, which gave way to the analysis of characteristic curves where it was found that the increase in water temperature influences the operation of the pump; affecting the delivered flow, height and performance. Three experimental designs were made for the characteristic curves Three experimental designs were made for the characteristic curves of the Pedrollo CPm130 pump, obtaining three mathematical models that it relates: Flow-Height (Q-Hman), Flow-Power electric (Q-Pe), Flow-Motorpump performance (Q-n); for which the number of factors and levels of each one were determined and with the help of specialized software, it was possible to obtain the mathematical models that respond to the variables of Height , Power and Performance. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UNL_7fe6f02f7dfeba06a8a15c247b1c34f4 |
| instacron_str | UNL |
| institution | UNL |
| instname_str | Universidad Nacional de Loja |
| language | spa |
| network_acronym_str | UNL |
| network_name_str | Repositorio Universidad Nacional de Loja |
| oai_identifier_str | oai:dspace.unl.edu.ec:123456789/22952 |
| publishDate | 2020 |
| publisher.none.fl_str_mv | Loja:Universidad Nacional de Loja |
| reponame_str | Repositorio Universidad Nacional de Loja |
| repository.mail.fl_str_mv | * |
| repository.name.fl_str_mv | Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga.Alvarado Alvarado, Victor Manuel<VARIACIÓN DE TEMPERATURA><BOMBA CENTRÍFUGA><CURVAS DE BOMBA><MODELO EXPERIMENTAL><BOMBA PEDROLLO CPM 130>In the present research work is proposed to analyze the effect of temperature variation of the working fluid on the characteristic curves of a centrifugal pump of ½ Hp brand Pedrollo CPm130. In the development of the document, the methodology used for data acquisition is detailed, and information regarding the influence that the temperature of the fluid has on a centrifugal pump was systematized by means of books, magazines, articles, etc. Based on this information, the necessary components that the test bench should have were determined. A practice guide was prepared based on the institutional format of the National University of Loja (UNL) and standard ISO 9906:1999, which facilitated the acquisition of data by means of the record sheet prepared from the above, which gave way to the analysis of characteristic curves where it was found that the increase in water temperature influences the operation of the pump; affecting the delivered flow, height and performance. Three experimental designs were made for the characteristic curves Three experimental designs were made for the characteristic curves of the Pedrollo CPm130 pump, obtaining three mathematical models that it relates: Flow-Height (Q-Hman), Flow-Power electric (Q-Pe), Flow-Motorpump performance (Q-n); for which the number of factors and levels of each one were determined and with the help of specialized software, it was possible to obtain the mathematical models that respond to the variables of Height , Power and Performance.En el presente trabajo de investigación se propone como objetivo principal analizar el efecto de variación de temperatura del fluido de trabajo en las curvas características de una bomba centrífuga de ½ Hp marca Pedrollo CPm130. En el desarrollo del documento se detalla la metodología utilizada para la adquisición de datos, además se sistematizó información referente a la influencia que tiene la temperatura del fluido en una bomba centrífuga mediante libros revistas artículos, etc., Con base a esta información se determinó los componentes necesarios que debe tener el banco de pruebas. Se elaboró una guía de prácticas con base al formato institucional de la Universidad Nacional de Loja (UNL) y norma ISO 9906:1999, que facilitó la adquisición de datos por medio de la hoja de registro elaborada a partir de lo antes mencionado, que dio paso al análisis de las curvas características donde se comprobó que el aumento de temperatura del agua influye en el funcionamiento de la bomba; afectando el caudal entregado, altura y rendimiento. Se realizaron tres diseños experimentales para las curvas características de la bomba Pedrollo CPm130, obteniendo tres modelos matemáticos que relaciona: Caudal-Altura (Q-Hman), Caudal-Potencia eléctrica (Q-Pe), Caudal-Rendimiento motobomba (Q-n); para lo cual se determinó el número de factores y niveles de cada uno y con ayuda de software especializados, se logró obtener los modelos matemáticos que dan respuesta a las variables de Altura, Potencia eléctrica y rendimiento.Loja:Universidad Nacional de LojaTapia Peralta, Darwin Giovanny2020-01-08T20:47:15Z2020-01-08T20:47:15Z2020-01-08info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis122 p.application/pdfhttp://dspace.unl.edu.ec/jspui/handle/123456789/22952spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T14:46:38Zoai:dspace.unl.edu.ec:123456789/22952Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T14:46:38falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T14:46:38Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse |
| spellingShingle | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. Alvarado Alvarado, Victor Manuel <VARIACIÓN DE TEMPERATURA><BOMBA CENTRÍFUGA><CURVAS DE BOMBA><MODELO EXPERIMENTAL><BOMBA PEDROLLO CPM 130> |
| status_str | publishedVersion |
| title | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| title_full | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| title_fullStr | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| title_full_unstemmed | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| title_short | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| title_sort | Efecto de variación de temperatura de trabajo en las curvas características de una bomba centrífuga. |
| topic | <VARIACIÓN DE TEMPERATURA><BOMBA CENTRÍFUGA><CURVAS DE BOMBA><MODELO EXPERIMENTAL><BOMBA PEDROLLO CPM 130> |
| url | http://dspace.unl.edu.ec/jspui/handle/123456789/22952 |