Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.

The THDI (total harmonic distortion of current) and THDV (total harmonic voltage distortion) are harmonics that are presented by the insertion of non-linear loads, such as induction cookers, ovens, among others, in an installation or electrical distribution network. The presence of harmonics generat...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autor: Mendoza Aguirre, Temístocles Valdemar (author)
Médium: bachelorThesis
Jazyk:spa
Vydáno: 2019
Témata:
On-line přístup:http://dspace.unl.edu.ec/jspui/handle/123456789/21614
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
_version_ 1857833129515941888
author Mendoza Aguirre, Temístocles Valdemar
author_facet Mendoza Aguirre, Temístocles Valdemar
author_role author
collection Repositorio Universidad Nacional de Loja
dc.contributor.none.fl_str_mv Carrión González, Jorge Enrique
dc.creator.none.fl_str_mv Mendoza Aguirre, Temístocles Valdemar
dc.date.none.fl_str_mv 2019-01-28T20:01:16Z
2019-01-28T20:01:16Z
2019-01-28
dc.format.none.fl_str_mv 104 p.
application/pdf
dc.identifier.none.fl_str_mv http://dspace.unl.edu.ec/jspui/handle/123456789/21614
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Loja: Universidad Nacional de Loja
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Loja
instname:Universidad Nacional de Loja
instacron:UNL
dc.subject.none.fl_str_mv <DISTORCIÓN ARMÓNICA TOTAL DE CORRIENTE (THDI)><DISTORCIÓN ARMÓNICA TOTAL DE VOLTAJE (THDV)><NORMA IEEE-519-2014><REGULACIÓN CONELEC 004/01><CARGA NO LINEAL>
dc.title.none.fl_str_mv Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The THDI (total harmonic distortion of current) and THDV (total harmonic voltage distortion) are harmonics that are presented by the insertion of non-linear loads, such as induction cookers, ovens, among others, in an installation or electrical distribution network. The presence of harmonics generates innumerable problems that affect the power quality of the electricity supply network. These non-sinusoidal loads generate losses, heating of conductors, decrease of the power factor and in the transformer degradation of the insulation, loss in the power supply, causing an increase of the operative costs and reduction of the useful life of the elements that make up the system. In this developed research THDI and THDV are evaluated in single-phase transformers of 10, 15, 25 and 37.5 kVA that supply energy to residential consumers in the province of Loja, using a database of measurements made over a period of 3 years (2013, 2014, 2015), with the objective of obtaining characteristic curves to observe the characteristic behavior of THDI and THDV in transformers that feed residential loads with and without induction cooker. After processing the database, statistical techniques were used to determine if the database complies with a normal distribution. Finally, characteristic curves of the THDI and THDV were obtained, where the time behavior of these two parameters can be appreciated.
eu_rights_str_mv openAccess
format bachelorThesis
id UNL_c3ed1a89e9a61bfefe12f3c04531cbb7
instacron_str UNL
institution UNL
instname_str Universidad Nacional de Loja
language spa
network_acronym_str UNL
network_name_str Repositorio Universidad Nacional de Loja
oai_identifier_str oai:dspace.unl.edu.ec:123456789/21614
publishDate 2019
publisher.none.fl_str_mv Loja: Universidad Nacional de Loja
reponame_str Repositorio Universidad Nacional de Loja
repository.mail.fl_str_mv *
repository.name.fl_str_mv Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.Mendoza Aguirre, Temístocles Valdemar<DISTORCIÓN ARMÓNICA TOTAL DE CORRIENTE (THDI)><DISTORCIÓN ARMÓNICA TOTAL DE VOLTAJE (THDV)><NORMA IEEE-519-2014><REGULACIÓN CONELEC 004/01><CARGA NO LINEAL>The THDI (total harmonic distortion of current) and THDV (total harmonic voltage distortion) are harmonics that are presented by the insertion of non-linear loads, such as induction cookers, ovens, among others, in an installation or electrical distribution network. The presence of harmonics generates innumerable problems that affect the power quality of the electricity supply network. These non-sinusoidal loads generate losses, heating of conductors, decrease of the power factor and in the transformer degradation of the insulation, loss in the power supply, causing an increase of the operative costs and reduction of the useful life of the elements that make up the system. In this developed research THDI and THDV are evaluated in single-phase transformers of 10, 15, 25 and 37.5 kVA that supply energy to residential consumers in the province of Loja, using a database of measurements made over a period of 3 years (2013, 2014, 2015), with the objective of obtaining characteristic curves to observe the characteristic behavior of THDI and THDV in transformers that feed residential loads with and without induction cooker. After processing the database, statistical techniques were used to determine if the database complies with a normal distribution. Finally, characteristic curves of the THDI and THDV were obtained, where the time behavior of these two parameters can be appreciated.La THDI (Distorsión armónica total de corriente) y THDV (Distorsión armónica total de voltaje) son armónicos que se presentan por la inserción de cargas no lineales, como cocinas de inducción, hornos, entre otros, en una instalación o red de distribución eléctrica. La presencia de armónicos genera innumerables problemas que afectan la calidad de energía de la red de suministro eléctrico. Estas cargas no sinusoidales generan pérdidas, calentamiento de conductores, disminución del factor de potencia y en el transformador degradación del aislamiento, pérdida en el suministro de potencia, provocando un incremento de los costos operativos y reducción de la vida útil de los elementos que componen el sistema. En esta investigación desarrollada se evalúa la THDI y THDV en los transformadores monofásicos de 10, 15, 25 y 37.5 kVA que suministran energía a consumidores residenciales en la provincia de Loja, utilizando una base de datos de mediciones realizadas durante un periodo de 3 años(2013, 2014, 2015), con el objetivo de obtener curvas características para observar el comportamiento característico de la THDI y THDV en transformadores que alimentan cargas residenciales con y sin cocina de inducción. Después de procesar la base de datos se utilizó técnicas estadísticas para verificar si los datos cumplen con una distribución normal. Finalmente se obtuvieron las curvas características de la THDI Y THDV donde se puede apreciar el comportamiento en el tiempo de estos dos parámetros.Loja: Universidad Nacional de LojaCarrión González, Jorge Enrique2019-01-28T20:01:16Z2019-01-28T20:01:16Z2019-01-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis104 p.application/pdfhttp://dspace.unl.edu.ec/jspui/handle/123456789/21614spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T17:00:50Zoai:dspace.unl.edu.ec:123456789/21614Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T17:00:50falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T17:00:50Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse
spellingShingle Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
Mendoza Aguirre, Temístocles Valdemar
<DISTORCIÓN ARMÓNICA TOTAL DE CORRIENTE (THDI)><DISTORCIÓN ARMÓNICA TOTAL DE VOLTAJE (THDV)><NORMA IEEE-519-2014><REGULACIÓN CONELEC 004/01><CARGA NO LINEAL>
status_str publishedVersion
title Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
title_full Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
title_fullStr Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
title_full_unstemmed Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
title_short Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
title_sort Evaluación de la Thdi y Thdv en transformadores de distribución monofásicos.
topic <DISTORCIÓN ARMÓNICA TOTAL DE CORRIENTE (THDI)><DISTORCIÓN ARMÓNICA TOTAL DE VOLTAJE (THDV)><NORMA IEEE-519-2014><REGULACIÓN CONELEC 004/01><CARGA NO LINEAL>
url http://dspace.unl.edu.ec/jspui/handle/123456789/21614