Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.

The present investigation emphasizes the thermal evaluation of two solar heaters of flat plate of different type of construction with 1.44 m^2of effective collection area. In the part experimentally, the flat plate solar collectors of the Faculty of Energy, Industries are used and the Non-Renewable...

Полное описание

Сохранить в:
Библиографические подробности
Главный автор: Vásquez Espinosa, Mario Antonio (author)
Формат: bachelorThesis
Язык:spa
Опубликовано: 2023
Предметы:
Online-ссылка:https://dspace.unl.edu.ec/jspui/handle/123456789/28430
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!
_version_ 1857833137796546560
author Vásquez Espinosa, Mario Antonio
author_facet Vásquez Espinosa, Mario Antonio
author_role author
collection Repositorio Universidad Nacional de Loja
dc.contributor.none.fl_str_mv Montaño Peralta, Thuesman Estuardo
dc.creator.none.fl_str_mv Vásquez Espinosa, Mario Antonio
dc.date.none.fl_str_mv 2023-11-21T17:04:35Z
2023-11-21T17:04:35Z
2023-11-21
dc.format.none.fl_str_mv 87 p.
application/pdf
dc.identifier.none.fl_str_mv https://dspace.unl.edu.ec/jspui/handle/123456789/28430
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Universidad Nacional de Loja
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Loja
instname:Universidad Nacional de Loja
instacron:UNL
dc.subject.none.fl_str_mv BALANCE ENERGÉTICO
COLECTOR SOLAR
EFICIENCIA TÉRMICA
SISTEMA DE MEDICIÓN TÉRMICA
EFICIENCIA ÓPTICA
dc.title.none.fl_str_mv Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The present investigation emphasizes the thermal evaluation of two solar heaters of flat plate of different type of construction with 1.44 m^2of effective collection area. In the part experimentally, the flat plate solar collectors of the Faculty of Energy, Industries are used and the Non-Renewable Natural Resources of the National University of Loja, in which through The implementation of a thermal measurement system in each collector allows the collection of water temperature data at the inlet of the collector, water temperature at the outlet of the collector, absorber plate temperature, glass cover temperature, temperature water inside the tank, ambient temperature and relative humidity; Additionally, the data of wind speed and solar radiation were obtained from Meteorological Station 50001- Faculty of Energy. During the monitoring period under the weather conditions of the city of Loja had sunny, combined (sunny-cloudy) and cloudy days, where for the month July it was obtained that the efficiency of the collector with an absorber plate of copper tubes arranged to the aluminum fins is 2.74% higher than the efficiency of the collector with an absorber plate galvanized zinc with copper tubes fitted to the collection plate. Based on this study It can be stated that in warm temperate climates the construction topology of an absorbent plate of copper tubes fixed to aluminum fins is more advantageous for the purposes of absorbed heat and thermal efficiency Keywords: energy balance, solar collector, thermal measurement system, thermal efficiency, optical efficiency.
eu_rights_str_mv openAccess
format bachelorThesis
id UNL_d7302cd9ad3ab4110ad64fed2cb01c77
instacron_str UNL
institution UNL
instname_str Universidad Nacional de Loja
language spa
network_acronym_str UNL
network_name_str Repositorio Universidad Nacional de Loja
oai_identifier_str oai:dspace.unl.edu.ec:123456789/28430
publishDate 2023
publisher.none.fl_str_mv Universidad Nacional de Loja
reponame_str Repositorio Universidad Nacional de Loja
repository.mail.fl_str_mv *
repository.name.fl_str_mv Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.Vásquez Espinosa, Mario AntonioBALANCE ENERGÉTICOCOLECTOR SOLAREFICIENCIA TÉRMICASISTEMA DE MEDICIÓN TÉRMICAEFICIENCIA ÓPTICAThe present investigation emphasizes the thermal evaluation of two solar heaters of flat plate of different type of construction with 1.44 m^2of effective collection area. In the part experimentally, the flat plate solar collectors of the Faculty of Energy, Industries are used and the Non-Renewable Natural Resources of the National University of Loja, in which through The implementation of a thermal measurement system in each collector allows the collection of water temperature data at the inlet of the collector, water temperature at the outlet of the collector, absorber plate temperature, glass cover temperature, temperature water inside the tank, ambient temperature and relative humidity; Additionally, the data of wind speed and solar radiation were obtained from Meteorological Station 50001- Faculty of Energy. During the monitoring period under the weather conditions of the city of Loja had sunny, combined (sunny-cloudy) and cloudy days, where for the month July it was obtained that the efficiency of the collector with an absorber plate of copper tubes arranged to the aluminum fins is 2.74% higher than the efficiency of the collector with an absorber plate galvanized zinc with copper tubes fitted to the collection plate. Based on this study It can be stated that in warm temperate climates the construction topology of an absorbent plate of copper tubes fixed to aluminum fins is more advantageous for the purposes of absorbed heat and thermal efficiency Keywords: energy balance, solar collector, thermal measurement system, thermal efficiency, optical efficiency.La presente investigación hace énfasis en la evaluación térmica de dos calentadores solares de placa plana de distinto tipo de construcción de 1,44 m^2 de área efectiva de captación. En la parte experimental se usa los colectores solares de placa plana de la Facultad de la Energía, las Industrias y los Recursos Naturales no Renovables de la Universidad Nacional de Loja, en la cual mediante la implementación de un sistema de medición térmica en cada colector permite la recolección de datos de temperatura del agua a la entrada del colector, temperatura del agua a la salida del colector, temperatura de la placa absorbedora, temperatura de la cubierta de vidrio, temperatura agua al interior del tanque, temperatura ambiente y humedad relativa; adicionalmente, los datos de velocidad del viento y radiación solar se obtuvieron de la Estación Meteorológica 50001- Facultad de la Energía. Durante el lapso de monitoreo bajo las condiciones climatológicas de la ciudad de Loja se presentaron días soleados, combinados (soleado-nublado) y nublados, donde para el mes de julio se obtuvo que la eficiencia del colector con placa absorbedora de tubos de cobre arreglados a las aletas de aluminio es un 2,74 % mayor que la eficiencia del colector con placa absorbedora de zinc galvanizado con tubos de cobre encajados a la placa de captación. En base a este estudio se puede afirmar que en climas cálidos templados la topología constructiva de una placa absorbente de tubos de cobre arreglados a las aletas de aluminio es más ventajosa a efectos de calor absorbido y eficiencia térmica. Palabras claves: balance energético, colector solar, sistema de medición térmica, eficiencia térmica, eficiencia óptica.Universidad Nacional de LojaMontaño Peralta, Thuesman Estuardo2023-11-21T17:04:35Z2023-11-21T17:04:35Z2023-11-21info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis87 p.application/pdfhttps://dspace.unl.edu.ec/jspui/handle/123456789/28430spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T17:11:41Zoai:dspace.unl.edu.ec:123456789/28430Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T17:11:41falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T17:11:41Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse
spellingShingle Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
Vásquez Espinosa, Mario Antonio
BALANCE ENERGÉTICO
COLECTOR SOLAR
EFICIENCIA TÉRMICA
SISTEMA DE MEDICIÓN TÉRMICA
EFICIENCIA ÓPTICA
status_str publishedVersion
title Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
title_full Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
title_fullStr Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
title_full_unstemmed Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
title_short Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
title_sort Análisis comparativo de dos calentadores solares de diferente tipo de construcción para las condiciones climatológicas y aplicaciones en la ciudad de Loja.
topic BALANCE ENERGÉTICO
COLECTOR SOLAR
EFICIENCIA TÉRMICA
SISTEMA DE MEDICIÓN TÉRMICA
EFICIENCIA ÓPTICA
url https://dspace.unl.edu.ec/jspui/handle/123456789/28430