Cranioencephalic trauma (CET) is one of the leading causes of death and the use of computerized axial tomography (CAT) to diagnose TBI is important, however, a workstation for reading medical images is not always available when the specialist The image is not available or is outside the hospital. Mo...

Бүрэн тодорхойлолт

-д хадгалсан:
Номзүйн дэлгэрэнгүй
Үндсэн зохиолч: Salas Guerrero, Ronald Fabricio (author)
Формат: bachelorThesis
Хэл сонгох:spa
Хэвлэсэн: 2018
Нөхцлүүд:
Онлайн хандалт:http://dspace.unl.edu.ec/jspui/handle/123456789/19976
Шошгууд: Шошго нэмэх
Шошго байхгүй, Энэхүү баримтыг шошголох эхний хүн болох!
_version_ 1857833183971639296
author Salas Guerrero, Ronald Fabricio
author_facet Salas Guerrero, Ronald Fabricio
author_role author
collection Repositorio Universidad Nacional de Loja
dc.contributor.none.fl_str_mv Reyes Luna, Marlon Rodrigo
dc.creator.none.fl_str_mv Salas Guerrero, Ronald Fabricio
dc.date.none.fl_str_mv 2018-01-22T23:23:35Z
2018-01-22T23:23:35Z
2018
dc.format.none.fl_str_mv 94 p.
application/pdf
dc.identifier.none.fl_str_mv http://dspace.unl.edu.ec/jspui/handle/123456789/19976
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Loja
instname:Universidad Nacional de Loja
instacron:UNL
dc.subject.none.fl_str_mv TOMOGRAFÍA COMPUTARIZADA
TRAUMATISMO CRANOENCEFÁLICO
VISOR DICOM
dc.title.none.fl_str_mv Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description Cranioencephalic trauma (CET) is one of the leading causes of death and the use of computerized axial tomography (CAT) to diagnose TBI is important, however, a workstation for reading medical images is not always available when the specialist The image is not available or is outside the hospital. Modern mobile devices allow real-time interpretation of radiology studies, so it is important to evaluate the reliability of using a mobile device for reading medical images in our environment; with which we set ourselves as objectives: to determine the reliability of the Dicom "OsiriX HD" reader in mobile devices in the remote reading of CT of patients with TBI and its limitations; the precision in determining the Score Rotterdam and; the utility when characterizing bruises, brain contusions and fractures. A CT scan was performed on 57 patients diagnosed with TBI; their studies were downloaded remotely in a workstation and on a mobile device; Two imaging readers were designated who performed the reading independently with the same number of images and sequences. When identifying the Rotterdam Score there were no significant discrepancies, the fractures coincided in 99.12%, intraaxial injuries coincided with 99.13%, the size and density showed insignificant differences showing that mobile device can be as precise as a workstation since it does not shows evidence indicative of disagreements when compared to a workstation dedicated to reading medical images. Keywords: Radiology, computer science, teleradiology, smartphone.
eu_rights_str_mv openAccess
format bachelorThesis
id UNL_d97bc74d9ec67d3ccfcae4f83a238aac
instacron_str UNL
institution UNL
instname_str Universidad Nacional de Loja
language spa
network_acronym_str UNL
network_name_str Repositorio Universidad Nacional de Loja
oai_identifier_str oai:dspace.unl.edu.ec:123456789/19976
publishDate 2018
reponame_str Repositorio Universidad Nacional de Loja
repository.mail.fl_str_mv *
repository.name.fl_str_mv Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.Salas Guerrero, Ronald FabricioTOMOGRAFÍA COMPUTARIZADATRAUMATISMO CRANOENCEFÁLICOVISOR DICOMCranioencephalic trauma (CET) is one of the leading causes of death and the use of computerized axial tomography (CAT) to diagnose TBI is important, however, a workstation for reading medical images is not always available when the specialist The image is not available or is outside the hospital. Modern mobile devices allow real-time interpretation of radiology studies, so it is important to evaluate the reliability of using a mobile device for reading medical images in our environment; with which we set ourselves as objectives: to determine the reliability of the Dicom "OsiriX HD" reader in mobile devices in the remote reading of CT of patients with TBI and its limitations; the precision in determining the Score Rotterdam and; the utility when characterizing bruises, brain contusions and fractures. A CT scan was performed on 57 patients diagnosed with TBI; their studies were downloaded remotely in a workstation and on a mobile device; Two imaging readers were designated who performed the reading independently with the same number of images and sequences. When identifying the Rotterdam Score there were no significant discrepancies, the fractures coincided in 99.12%, intraaxial injuries coincided with 99.13%, the size and density showed insignificant differences showing that mobile device can be as precise as a workstation since it does not shows evidence indicative of disagreements when compared to a workstation dedicated to reading medical images. Keywords: Radiology, computer science, teleradiology, smartphone.El trauma craneoencefálico (TCE) es una de las principales causas de muerte y el empleo de tomografía axial computarizada (TAC) para diagnosticar TCE es importante, sin embargo, no siempre se dispone de una estación de trabajo para lectura de imágenes médicas cuando el especialista en imagen no se encuentra disponible o se halla fuera del hospital. Los dispositivos móviles modernos permiten la interpretación en tiempo real de los estudios de radiología, por lo cual es importante evaluar la confiabilidad de usar un dispositivo móvil para la lectura de imágenes médicas en nuestro medio; con lo cual nos planteamos como objetivos: determinar la confiablidad del lector Dicom “OsiriX HD” en dispositivos móviles en la lectura remota de TAC de pacientes con TCE y sus limitaciones; la precisión al determinar el Score Rotterdam y; la utilidad al caracterizar hematomas, contusiones cerebrales y fracturas. A 57 pacientes diagnosticados con TCE se les realizó una TAC, sus estudios se descargaron vía remota en una estación de trabajo y en un dispositivo móvil; se designaron a dos lectores imagenólogos quienes realizaron la lectura en forma independiente con el mismo número de imágenes y secuencias. Al identificar el Score Rotterdam no se presenta discrepancias significativas, las fracturas coincidieron en un 99.12%, lesiones intraaxiales coincidieron 99.13%, el tamaño y densidad presentan diferencias poco significativas demostrando que dispositivo móvil puede ser tan preciso como una estación de trabajo ya que no se muestra evidencia indicativa de discordancias al momento de compararlo con una estación de trabajo dedicada a la lectura de imágenes médicas. Palabras clave: Radiología, informática, teleradiología, teléfono inteligente.Reyes Luna, Marlon Rodrigo2018-01-22T23:23:35Z2018-01-22T23:23:35Z2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis94 p.application/pdfhttp://dspace.unl.edu.ec/jspui/handle/123456789/19976spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T18:08:43Zoai:dspace.unl.edu.ec:123456789/19976Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T18:08:43falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T18:08:43Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse
spellingShingle Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
Salas Guerrero, Ronald Fabricio
TOMOGRAFÍA COMPUTARIZADA
TRAUMATISMO CRANOENCEFÁLICO
VISOR DICOM
status_str publishedVersion
title Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
title_full Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
title_fullStr Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
title_full_unstemmed Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
title_short Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
title_sort Utilidad de un visor Dicom para dispositivos móviles en la valoración remota de tomografías de pacientes con traumatismo craneoencefálico en el Hospital Isidro Ayora de Loja.
topic TOMOGRAFÍA COMPUTARIZADA
TRAUMATISMO CRANOENCEFÁLICO
VISOR DICOM
url http://dspace.unl.edu.ec/jspui/handle/123456789/19976