Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo

In clinical practice, the physical characteristics of the instruments used in endodontics, it is observed that the design of its stretch marks, irregularities and cutting angles facilitates the retention of detritus and microorganisms, thus hindering a complete removal of the biological material dur...

Popoln opis

Shranjeno v:
Bibliografske podrobnosti
Glavni avtor: Quezada Cumbicos, Verónica del Cisne (author)
Format: bachelorThesis
Jezik:spa
Izdano: 2019
Teme:
Online dostop:http://dspace.unl.edu.ec/jspui/handle/123456789/22587
Oznake: Označite
Brez oznak, prvi označite!
_version_ 1857833194396581888
author Quezada Cumbicos, Verónica del Cisne
author_facet Quezada Cumbicos, Verónica del Cisne
author_role author
collection Repositorio Universidad Nacional de Loja
dc.contributor.none.fl_str_mv Barragán Ordóñez, Andrés Eugenio
dc.creator.none.fl_str_mv Quezada Cumbicos, Verónica del Cisne
dc.date.none.fl_str_mv 2019-10-22T22:11:15Z
2019-10-22T22:11:15Z
2019
dc.format.none.fl_str_mv 102 p.
application/pdf
dc.identifier.none.fl_str_mv http://dspace.unl.edu.ec/jspui/handle/123456789/22587
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Nacional de Loja
instname:Universidad Nacional de Loja
instacron:UNL
dc.subject.none.fl_str_mv MICROBIOLOGÍA
BACTERIA GRAM POSITIVA
MICROORGANISMOS - ENDODONCIA
BIOSEGURIDAD - SALUD
dc.title.none.fl_str_mv Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description In clinical practice, the physical characteristics of the instruments used in endodontics, it is observed that the design of its stretch marks, irregularities and cutting angles facilitates the retention of detritus and microorganisms, thus hindering a complete removal of the biological material during the cleaning, disinfection and sterilization process. This study aims to verify the presence of microorganisms in endodontic instruments. The method used in this research was performed randomly in the facilities of the Dental Clinic No. 1 of the National University of Loja, for which 100 files of different students who completed their endodontic treatments were selected. Then, 50 treatment files were taken in adults ( type K files, 8 endodontic treatments) and 50 treatment files in children (type H files, 7 endodontic treatments) they were subjected to sterilization processes in dry heat and humid heat, to be later taken to the laboratory of the Medilab clinic in the city of Loja. The result obtained indicates that the type K files submitted to the wet heat sterilization process were the most contaminated by aerobic bacteria, where they presented a bacteriological count of 280,000 CFU / ml, while type H files obtained an average of 260,000 CFU / ml. Conclusion: the bacteria found in the type K files submitted to the wet heat sterilization process were Escherichia coli 23.08%, Streptococcus beta-hemolytic group A 26.92%, Streptococcus spp 26.92% and Staphylococcus saprophyticus with 23.08%. Meanwhile, the bacterium found in type H files submitted to the dry heat sterilization process was Staphylococcus aureus Meticilino sensible, Bacillus spp, and Staphylococcus saprophyticus with 33.33% each one. As a recommendation, undergraduate students should continue to be made aware of the importance of proper cleaning and disinfection of the instruments to be used. Keywords: microorganisms, aerobic bacteria, endodontic files, sterilization.
eu_rights_str_mv openAccess
format bachelorThesis
id UNL_fbc28e09c910330bc0f8a4eb7ccf5011
instacron_str UNL
institution UNL
instname_str Universidad Nacional de Loja
language spa
network_acronym_str UNL
network_name_str Repositorio Universidad Nacional de Loja
oai_identifier_str oai:dspace.unl.edu.ec:123456789/22587
publishDate 2019
reponame_str Repositorio Universidad Nacional de Loja
repository.mail.fl_str_mv *
repository.name.fl_str_mv Repositorio Universidad Nacional de Loja - Universidad Nacional de Loja
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedoQuezada Cumbicos, Verónica del CisneMICROBIOLOGÍABACTERIA GRAM POSITIVAMICROORGANISMOS - ENDODONCIABIOSEGURIDAD - SALUDIn clinical practice, the physical characteristics of the instruments used in endodontics, it is observed that the design of its stretch marks, irregularities and cutting angles facilitates the retention of detritus and microorganisms, thus hindering a complete removal of the biological material during the cleaning, disinfection and sterilization process. This study aims to verify the presence of microorganisms in endodontic instruments. The method used in this research was performed randomly in the facilities of the Dental Clinic No. 1 of the National University of Loja, for which 100 files of different students who completed their endodontic treatments were selected. Then, 50 treatment files were taken in adults ( type K files, 8 endodontic treatments) and 50 treatment files in children (type H files, 7 endodontic treatments) they were subjected to sterilization processes in dry heat and humid heat, to be later taken to the laboratory of the Medilab clinic in the city of Loja. The result obtained indicates that the type K files submitted to the wet heat sterilization process were the most contaminated by aerobic bacteria, where they presented a bacteriological count of 280,000 CFU / ml, while type H files obtained an average of 260,000 CFU / ml. Conclusion: the bacteria found in the type K files submitted to the wet heat sterilization process were Escherichia coli 23.08%, Streptococcus beta-hemolytic group A 26.92%, Streptococcus spp 26.92% and Staphylococcus saprophyticus with 23.08%. Meanwhile, the bacterium found in type H files submitted to the dry heat sterilization process was Staphylococcus aureus Meticilino sensible, Bacillus spp, and Staphylococcus saprophyticus with 33.33% each one. As a recommendation, undergraduate students should continue to be made aware of the importance of proper cleaning and disinfection of the instruments to be used. Keywords: microorganisms, aerobic bacteria, endodontic files, sterilization.En la práctica clínica, las características físicas de los instrumentos utilizados en endodoncia, se observa que el diseño de sus estrías, irregularidades y ángulos de corte facilitan la retención de detritus y microorganismos, dificultando así una completa remoción del material biológico durante el proceso de limpieza, desinfección y esterilización. Este estudio se realizó con el objetivo de constatar la presencia de microorganismos en el instrumental endodóntico. El método empleado en esta investigación se realizó aleatoriamente en las instalaciones de la Clínica Odontológica Nº 1 de la Universidad Nacional de Loja, para lo cual se seleccionaron 100 limas de diferentes alumnos que culminaron sus tratamientos endodónticos, luego se tomó 50 limas de tratamientos en adultos (limas tipo K, 8 tratamientos endodónticos) y 50 limas de tratamientos en niños (limas tipo H, 7 tratamientos endodónticos) se las sometió a procesos de esterilización en calor seco y calor húmedo, para posteriormente ser llevadas al laboratorio de la clínica Medilab de la ciudad de Loja. El resultado que se obtuvo fue que las limas tipo K sometidas al proceso de esterilización en calor húmedo eran las más contaminadas por bacterias aerobias, en donde presentaron un recuento bacteriológico de 280.000 UFC/ml, mientras que las limas tipo H obtuvieron un promedio de 260.000 UFC/ml. Como conclusión se obtuvo que las bacterias que se encontraron en las limas tipo K sometidas al proceso de esterilización en calor húmedo fueron, Escherichia coli 23.08%, Streptococcus beta hemolítico del grupo A 26.92%, Streptococcus spp 26.92% y Sthaphylococcus saprophyticus con el 23.08%, entretanto que las bacterias encontradas en las limas tipo H sometidas al proceso de esterilización en calor seco fueron, Sthaphylococcus aeureus Meticilino sensible, Bacillus spp y Sthaphylococcus saprophyticus con el 33.33% cada una. Como recomendación se debe seguir concientizando a los estudiantes de pregrado sobre la importancia de una correcta limpieza y desinfección del instrumental a utilizar. Palabras Claves: microorganismos, bacterias aerobias, limas de endodoncia, esterilización.Barragán Ordóñez, Andrés Eugenio2019-10-22T22:11:15Z2019-10-22T22:11:15Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis102 p.application/pdfhttp://dspace.unl.edu.ec/jspui/handle/123456789/22587spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Nacional de Lojainstname:Universidad Nacional de Lojainstacron:UNL2025-05-02T18:19:52Zoai:dspace.unl.edu.ec:123456789/22587Institucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oaiEcuador***opendoar:02025-05-02T18:19:52falseInstitucionalhttps://dspace.unl.edu.ec/Universidad públicahttps://unl.edu.ec/https://dspace.unl.edu.ec/oai*Ecuador***opendoar:02025-05-02T18:19:52Repositorio Universidad Nacional de Loja - Universidad Nacional de Lojafalse
spellingShingle Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
Quezada Cumbicos, Verónica del Cisne
MICROBIOLOGÍA
BACTERIA GRAM POSITIVA
MICROORGANISMOS - ENDODONCIA
BIOSEGURIDAD - SALUD
status_str publishedVersion
title Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
title_full Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
title_fullStr Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
title_full_unstemmed Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
title_short Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
title_sort Agentes microbianos en el instrumental endodóntico según el protocolo de esterilización en calor seco y húmedo
topic MICROBIOLOGÍA
BACTERIA GRAM POSITIVA
MICROORGANISMOS - ENDODONCIA
BIOSEGURIDAD - SALUD
url http://dspace.unl.edu.ec/jspui/handle/123456789/22587