Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.

The systems of protection and control of the Substation North have suffered one alteration in his original design, due to the fact that several of the protection relays electromechanical, they have been replaced already be for defective functioning or for requirements of the system. Using for this e...

Fuld beskrivelse

Saved in:
Bibliografiske detaljer
Hovedforfatter: Alomoto Aldana, Christian Mario (author)
Format: bachelorThesis
Sprog:spa
Udgivet: 2010
Fag:
Online adgang:http://dspace.ups.edu.ec/handle/123456789/4758
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
_version_ 1863428301962346496
author Alomoto Aldana, Christian Mario
author_facet Alomoto Aldana, Christian Mario
author_role author
collection Repositorio Universidad Politécnica Salesiana
dc.contributor.none.fl_str_mv Vásquez Teneda, Franklin Hernán
dc.creator.none.fl_str_mv Alomoto Aldana, Christian Mario
dc.date.none.fl_str_mv 2010-11
2013-07-04T20:32:11Z
2013-07-04T20:32:11Z
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.identifier.none.fl_str_mv http://dspace.ups.edu.ec/handle/123456789/4758
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Politécnica Salesiana
instname:Universidad Politécnica Salesiana
instacron:UPS
dc.subject.none.fl_str_mv ELÉCTRICA
DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
SUBESTACIONES ELÉCTRICAS
RELÉS PROTECTORES
ELECTRICIDAD - DISPOSITIVOS DE DISTRIBUCIÓN
dc.title.none.fl_str_mv Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The systems of protection and control of the Substation North have suffered one alteration in his original design, due to the fact that several of the protection relays electromechanical, they have been replaced already be for defective functioning or for requirements of the system. Using for this effect equipment of last technology as relays IEDs or Alphanumeric, since they are those who nowadays are commercialized. To adapt a modern technology to ancient systems has caused technical problems as: Disarticulation of the planes of the subastation. Breaking up the planes of the subastation. Descoordinación of protections. Waste of resorces, between otherrs. The Reconfiguration of the schemes of control and protection of S/E North by means of alphanumeric relays, Part of the need to eliminate the problems caused for using several technologies, as well as of modernizing the facilities of the subastation, for which realized the following works: Analysis of the systems of protections of the Subastation North, Levantamiento and actualización of planes. Study of the characteristics and operation of the IEDs alphanumeric that used. Design of the reconfiguration of the schemes of control and protection. Design of leaves of wired up. Customization of the relays alphanumeric used IEDs. The development of this process plasma in the present work of Thesis.
eu_rights_str_mv openAccess
format bachelorThesis
id UPS_09a0d8b3f0ad442564bef4feb001a10a
instacron_str UPS
institution UPS
instname_str Universidad Politécnica Salesiana
language spa
network_acronym_str UPS
network_name_str Repositorio Universidad Politécnica Salesiana
oai_identifier_str oai:dspace.ups.edu.ec:123456789/4758
publishDate 2010
reponame_str Repositorio Universidad Politécnica Salesiana
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana
repository_id_str 1737
spelling Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.Alomoto Aldana, Christian MarioELÉCTRICADISTRIBUCIÓN DE ENERGÍA ELÉCTRICASUBESTACIONES ELÉCTRICASRELÉS PROTECTORESELECTRICIDAD - DISPOSITIVOS DE DISTRIBUCIÓNThe systems of protection and control of the Substation North have suffered one alteration in his original design, due to the fact that several of the protection relays electromechanical, they have been replaced already be for defective functioning or for requirements of the system. Using for this effect equipment of last technology as relays IEDs or Alphanumeric, since they are those who nowadays are commercialized. To adapt a modern technology to ancient systems has caused technical problems as: Disarticulation of the planes of the subastation. Breaking up the planes of the subastation. Descoordinación of protections. Waste of resorces, between otherrs. The Reconfiguration of the schemes of control and protection of S/E North by means of alphanumeric relays, Part of the need to eliminate the problems caused for using several technologies, as well as of modernizing the facilities of the subastation, for which realized the following works: Analysis of the systems of protections of the Subastation North, Levantamiento and actualización of planes. Study of the characteristics and operation of the IEDs alphanumeric that used. Design of the reconfiguration of the schemes of control and protection. Design of leaves of wired up. Customization of the relays alphanumeric used IEDs. The development of this process plasma in the present work of Thesis.Los sistemas de protección y control de la Subestación Norte han sufrido una alteración en su diseño original, debido a que varios de los relés de protección electromecánicos han sido sustituidos ya sea por funcionamiento defectuoso o por requerimientos del sistema. Utilizando para este efecto equipos de última tecnología como relés IEDs o Alfanuméricos, puesto que son los que actualmente se comercializan. El adaptar una tecnología moderna a sistemas antiguos ha ocasionado problemas técnicos como: Desarticulación de los planos de la subestación, Descoordinación de protecciones Desperdicio de recursos, entre otros. La reconfiguración de los esquemas de control y protección de la S/E Norte mediante relés alfanuméricos, parte de la necesidad de eliminar los problemas ocasionados por ésta mescla de tecnologías, así como de modernizar las instalaciones de la subestación, para lo cual se realizó los siguientes trabajos: Estudio de las características de funcionamiento de los equipos de la subestación Norte. Análisis del sistema de protecciones de la Subestación Norte, Levantamiento y actualización de planos. Estudio de las características y funcionamiento de los IEDs alfanuméricos que se utilizaron. Diseño de la reconfiguración de los esquemas de control y protección. Diseño de hojas de cableado. Parametrización de los relés IEDs alfanuméricos utilizados. Análisis económico del proceso de reconfiguración. El desarrollo de este proceso se plasma en el presente trabajo de Tesis.Vásquez Teneda, Franklin Hernán2013-07-04T20:32:11Z2013-07-04T20:32:11Z2010-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/4758spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:52:57Zoai:dspace.ups.edu.ec:123456789/4758Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:52:57Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse
spellingShingle Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
Alomoto Aldana, Christian Mario
ELÉCTRICA
DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
SUBESTACIONES ELÉCTRICAS
RELÉS PROTECTORES
ELECTRICIDAD - DISPOSITIVOS DE DISTRIBUCIÓN
status_str publishedVersion
title Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
title_full Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
title_fullStr Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
title_full_unstemmed Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
title_short Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
title_sort Reconfiguración de los esquemas de protección y control mediante relés alfanuméricos para modernizar la subestación norte de la E.E.Q. SA.
topic ELÉCTRICA
DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
SUBESTACIONES ELÉCTRICAS
RELÉS PROTECTORES
ELECTRICIDAD - DISPOSITIVOS DE DISTRIBUCIÓN
url http://dspace.ups.edu.ec/handle/123456789/4758