Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW.
The work presented in this paper contemplates the analysis of overcurrent and overvoltage protections in a three-phase distribution substation (69 KV / 13.8 KV - 12 / 16 MVA), air-insulated (AIS), using mathematical modeling for the power transformer, circuit breakers, reclosers, fuses, overcurrent...
Na minha lista:
| Autor principal: | |
|---|---|
| Formato: | bachelorThesis |
| Idioma: | spa |
| Publicado em: |
2021
|
| Assuntos: | |
| Acesso em linha: | http://dspace.ups.edu.ec/handle/123456789/21331 |
| Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
| _version_ | 1858988331160829952 |
|---|---|
| author | Vera Suárez, Diego Alejandro |
| author_facet | Vera Suárez, Diego Alejandro |
| author_role | author |
| collection | Repositorio Universidad Politécnica Salesiana |
| dc.contributor.none.fl_str_mv | Astudillo Astudillo, Otto |
| dc.creator.none.fl_str_mv | Vera Suárez, Diego Alejandro |
| dc.date.none.fl_str_mv | 2021-11-16T17:13:06Z 2021-11-16T17:13:06Z 2021 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | http://dspace.ups.edu.ec/handle/123456789/21331 |
| dc.language.none.fl_str_mv | spa |
| dc.rights.none.fl_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Politécnica Salesiana instname:Universidad Politécnica Salesiana instacron:UPS |
| dc.subject.none.fl_str_mv | PROTECCIONES SOBRETENSIONES SOBRECORRIENTES DESCARGAS ATMOSFÉRICAS DPS |
| dc.title.none.fl_str_mv | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | The work presented in this paper contemplates the analysis of overcurrent and overvoltage protections in a three-phase distribution substation (69 KV / 13.8 KV - 12 / 16 MVA), air-insulated (AIS), using mathematical modeling for the power transformer, circuit breakers, reclosers, fuses, overcurrent relay, current differential relay and surge arresters, using DigSilent short-circuit analysis computational tools and for simulations of overcurrent and overvoltage protection, circuit breakers , reclosers , fuses , overcurrent relay , current differential relay and surge arresters , using computational tools for short circuit analysis DigSilent and for transient voltage and current simulations in ATP Draw. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UPS_19a3eb229bc2eebe1e3fe1f343bba010 |
| instacron_str | UPS |
| institution | UPS |
| instname_str | Universidad Politécnica Salesiana |
| language | spa |
| network_acronym_str | UPS |
| network_name_str | Repositorio Universidad Politécnica Salesiana |
| oai_identifier_str | oai:dspace.ups.edu.ec:123456789/21331 |
| publishDate | 2021 |
| reponame_str | Repositorio Universidad Politécnica Salesiana |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana |
| repository_id_str | 1737 |
| rights_invalid_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ |
| spelling | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW.Vera Suárez, Diego AlejandroPROTECCIONESSOBRETENSIONESSOBRECORRIENTESDESCARGAS ATMOSFÉRICASDPSThe work presented in this paper contemplates the analysis of overcurrent and overvoltage protections in a three-phase distribution substation (69 KV / 13.8 KV - 12 / 16 MVA), air-insulated (AIS), using mathematical modeling for the power transformer, circuit breakers, reclosers, fuses, overcurrent relay, current differential relay and surge arresters, using DigSilent short-circuit analysis computational tools and for simulations of overcurrent and overvoltage protection, circuit breakers , reclosers , fuses , overcurrent relay , current differential relay and surge arresters , using computational tools for short circuit analysis DigSilent and for transient voltage and current simulations in ATP Draw.El trabajo presentado en este documento contempla el análisis de protecciones ante sobrecorrientes y sobretensiones en una subestación trifásica de distribución (69 KV / 13,8 KV - 12 / 16 MVA), aislada en aire (AIS), utilizando modelados matemáticos para el transformador de potencia, interruptores, reconectadores, fusibles, relé de sobrecorriente, relé diferencial de corriente y descargadores de sobretensión, utilizando herramientas computacionales para el análisis de corto circuito DigSilent y para simulaciones transitorias de voltaje y corriente en ATP Draw.Astudillo Astudillo, Otto2021-11-16T17:13:06Z2021-11-16T17:13:06Z2021info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/21331spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2022-01-26T18:19:48Zoai:dspace.ups.edu.ec:123456789/21331Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372022-01-26T18:19:48Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse |
| spellingShingle | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. Vera Suárez, Diego Alejandro PROTECCIONES SOBRETENSIONES SOBRECORRIENTES DESCARGAS ATMOSFÉRICAS DPS |
| status_str | publishedVersion |
| title | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| title_full | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| title_fullStr | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| title_full_unstemmed | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| title_short | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| title_sort | Análisis de protecciones para sobrecorrientes y sobretensiones en una subestación eléctrica de 69/13.8 KV, 16/24 MVA. Utilizando DIGSILENT Y ATPDRAW. |
| topic | PROTECCIONES SOBRETENSIONES SOBRECORRIENTES DESCARGAS ATMOSFÉRICAS DPS |
| url | http://dspace.ups.edu.ec/handle/123456789/21331 |