Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp

A direct-expansion solar-assisted heat pump system by using R600a as refrigerant is described in this project. The system mainly includes a flat-plate solar collector of total are 1 m2, acting as an evaporator, a hermetically sealed reciprocating type compressor of 1/6 hp, a straight copper tube hav...

पूर्ण विवरण

में बचाया:
ग्रंथसूची विवरण
मुख्य लेखक: Valenzuela Pazmiño, Max Henry (author)
अन्य लेखक: Haro Novoa, David Alexander (author)
स्वरूप: bachelorThesis
भाषा:spa
प्रकाशित: 2018
विषय:
ऑनलाइन पहुंच:https://dspace.ups.edu.ec/handle/123456789/16064
टैग: टैग जोड़ें
कोई टैग नहीं, इस रिकॉर्ड को टैग करने वाले पहले व्यक्ति बनें!
_version_ 1858988490509778944
author Valenzuela Pazmiño, Max Henry
author2 Haro Novoa, David Alexander
author2_role author
author_facet Valenzuela Pazmiño, Max Henry
Haro Novoa, David Alexander
author_role author
collection Repositorio Universidad Politécnica Salesiana
dc.contributor.none.fl_str_mv Quitiaquez Sarzosa, William Giovanny
dc.creator.none.fl_str_mv Valenzuela Pazmiño, Max Henry
Haro Novoa, David Alexander
dc.date.none.fl_str_mv 2018-09-10T15:06:24Z
2018-09-10T15:06:24Z
2018-08
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://dspace.ups.edu.ec/handle/123456789/16064
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Politécnica Salesiana
instname:Universidad Politécnica Salesiana
instacron:UPS
dc.subject.none.fl_str_mv INGENIERÍA MECÁNICA
BOMBAS DE CALOR
REFRIGERACIÓN
REFRIGERANTES
ENERGÍA EÓLICA
ESTUDIO DE FACTIBILIDAD
dc.title.none.fl_str_mv Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description A direct-expansion solar-assisted heat pump system by using R600a as refrigerant is described in this project. The system mainly includes a flat-plate solar collector of total are 1 m2, acting as an evaporator, a hermetically sealed reciprocating type compressor of 1/6 hp, a straight copper tube having an inner diameter of 3/16” as condenser and an electronic expansion valve. Data was observed every five minutes, during four tests per day, tests have an average period of 70 minutes. The system objective was to raise the water temperature to about 45 ° C. The highest temperature observed inside the water storage tank was 45.3 ° C in a period of 75 minutes. The system was influenced by varying weather conditions. An average radiation and an average room temperature of 556.75 W/m2, 20.7 ° C respectively was present those days. This type of system has a high initial investment, however, it can be recovered in the long term and they are friendly to the environment by not using fossil fuels, in addition to the possible eradication of hundreds of kilograms of CO2 per year.
eu_rights_str_mv openAccess
format bachelorThesis
id UPS_3d25780f2bd114dd4b6b70dc36afca8d
instacron_str UPS
institution UPS
instname_str Universidad Politécnica Salesiana
language spa
network_acronym_str UPS
network_name_str Repositorio Universidad Politécnica Salesiana
oai_identifier_str oai:dspace.ups.edu.ec:123456789/16064
publishDate 2018
reponame_str Repositorio Universidad Politécnica Salesiana
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana
repository_id_str 1737
rights_invalid_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
spelling Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hpValenzuela Pazmiño, Max HenryHaro Novoa, David AlexanderINGENIERÍA MECÁNICABOMBAS DE CALORREFRIGERACIÓNREFRIGERANTESENERGÍA EÓLICAESTUDIO DE FACTIBILIDADA direct-expansion solar-assisted heat pump system by using R600a as refrigerant is described in this project. The system mainly includes a flat-plate solar collector of total are 1 m2, acting as an evaporator, a hermetically sealed reciprocating type compressor of 1/6 hp, a straight copper tube having an inner diameter of 3/16” as condenser and an electronic expansion valve. Data was observed every five minutes, during four tests per day, tests have an average period of 70 minutes. The system objective was to raise the water temperature to about 45 ° C. The highest temperature observed inside the water storage tank was 45.3 ° C in a period of 75 minutes. The system was influenced by varying weather conditions. An average radiation and an average room temperature of 556.75 W/m2, 20.7 ° C respectively was present those days. This type of system has a high initial investment, however, it can be recovered in the long term and they are friendly to the environment by not using fossil fuels, in addition to the possible eradication of hundreds of kilograms of CO2 per year.El presente proyecto radica en el diseño y construcción de una bomba de calor de expansión directa asistida por energía solar, la cual está compuesta por: un colector-evaporador de placa plana elaborado en aluminio revestido con pintura negra, con un área de 1 m2. Consta también de un compresor de 1/6 hp que utiliza R600a como fluido de trabajo. El condensador fue elaborado a partir de tubería de cobre de 0,716 mm de espesor, en diámetros de 1/4'’ y 3/16’’. Las pruebas realizadas consistieron en la obtención de datos experimentales observados cada 5 minutos en cuatro diferentes ensayos al día, con un periodo promedio de 70 minutos por cada ciclo de funcionamiento del equipo, cuyo objetivo fue elevar la temperatura del agua hasta cerca de 45 °C. La temperatura máxima observada en las pruebas dentro del tanque de almacenamiento de agua fue de 45,3 °C en un período de 75 minutos. El sistema estuvo sometido a condiciones climáticas variantes, hubo días sobre todo despejados, con un valor promedio de radiación de 556.75 W/m2 y a una temperatura ambiente promedio de 20.7 °C. En la práctica un sistema de este tipo presenta una inversión inicial elevada, sin embargo, puede ser recuperada a largo plazo, además de ser amigable con el medio ambiente al no usar combustibles fósiles y disminuir la producción de cientos de kilogramos de CO2 al año.Quitiaquez Sarzosa, William Giovanny2018-09-10T15:06:24Z2018-09-10T15:06:24Z2018-08info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttps://dspace.ups.edu.ec/handle/123456789/16064spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2023-12-13T21:03:04Zoai:dspace.ups.edu.ec:123456789/16064Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372023-12-13T21:03:04Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse
spellingShingle Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
Valenzuela Pazmiño, Max Henry
INGENIERÍA MECÁNICA
BOMBAS DE CALOR
REFRIGERACIÓN
REFRIGERANTES
ENERGÍA EÓLICA
ESTUDIO DE FACTIBILIDAD
status_str publishedVersion
title Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
title_full Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
title_fullStr Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
title_full_unstemmed Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
title_short Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
title_sort Estudio de factibilidad para el uso de refrigerantes R134a, R123, R600a en una bomba de calor asistida por energía solar utilizando un compresor de 1/6 hp
topic INGENIERÍA MECÁNICA
BOMBAS DE CALOR
REFRIGERACIÓN
REFRIGERANTES
ENERGÍA EÓLICA
ESTUDIO DE FACTIBILIDAD
url https://dspace.ups.edu.ec/handle/123456789/16064