Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”.
In the "Colonso" protective forest located in the Tena city, Napo province, this paper titling, which ended with the automation of the mixing chamber of the treatment plant water "Colonso" was held this he made in order to ensure that the vital fluid consumed by the population of...
Salvato in:
| Autore principale: | |
|---|---|
| Natura: | bachelorThesis |
| Lingua: | spa |
| Pubblicazione: |
2016
|
| Soggetti: | |
| Accesso online: | http://dspace.ups.edu.ec/handle/123456789/13080 |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1858355892014022656 |
|---|---|
| author | Constante Agualsaca, Andrea Stefania |
| author_facet | Constante Agualsaca, Andrea Stefania |
| author_role | author |
| collection | Repositorio Universidad Politécnica Salesiana |
| dc.contributor.none.fl_str_mv | Pérez Checa, Aníbal Roberto |
| dc.creator.none.fl_str_mv | Constante Agualsaca, Andrea Stefania |
| dc.date.none.fl_str_mv | 2016-11-30T16:26:12Z 2016-11-30T16:26:12Z 2016-05 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | http://dspace.ups.edu.ec/handle/123456789/13080 |
| dc.language.none.fl_str_mv | spa |
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Politécnica Salesiana instname:Universidad Politécnica Salesiana instacron:UPS |
| dc.subject.none.fl_str_mv | CONTROL AUTOMÁTICO AGUA - PURIFICACIÓN |
| dc.title.none.fl_str_mv | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | In the "Colonso" protective forest located in the Tena city, Napo province, this paper titling, which ended with the automation of the mixing chamber of the treatment plant water "Colonso" was held this he made in order to ensure that the vital fluid consumed by the population of the Tena city is within the parameters set by the INEN 1108 standard. For this purpose various types of sensors that are responsible for providing readings of turbidity and pH which are typical characteristics of water, was implemented these data are processed by electronic devices through communication protocols signals are transformed so that the PLC can process and implement actions in conjunction with the actuators assigned according to the need of the situation, this according to the programming logic previously set in the control device. This whole process has been based on chemical and checks performed laboratory equipment, which have been performing manually but that control water before consumption, rationales implementation has been carried out by various control systems that allow the dosages of chemicals are completed accurately and in a timely manner, ensuring that drinking water is at the appropriate levels, and the process to comply mixing chamber can be displayed via an HMI that contains a complete graphical environment of water treatment |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UPS_6562aa37594de8073245ae0144b8ffef |
| instacron_str | UPS |
| institution | UPS |
| instname_str | Universidad Politécnica Salesiana |
| language | spa |
| network_acronym_str | UPS |
| network_name_str | Repositorio Universidad Politécnica Salesiana |
| oai_identifier_str | oai:dspace.ups.edu.ec:123456789/13080 |
| publishDate | 2016 |
| reponame_str | Repositorio Universidad Politécnica Salesiana |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana |
| repository_id_str | 1737 |
| spelling | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”.Constante Agualsaca, Andrea StefaniaCONTROL AUTOMÁTICOAGUA - PURIFICACIÓNIn the "Colonso" protective forest located in the Tena city, Napo province, this paper titling, which ended with the automation of the mixing chamber of the treatment plant water "Colonso" was held this he made in order to ensure that the vital fluid consumed by the population of the Tena city is within the parameters set by the INEN 1108 standard. For this purpose various types of sensors that are responsible for providing readings of turbidity and pH which are typical characteristics of water, was implemented these data are processed by electronic devices through communication protocols signals are transformed so that the PLC can process and implement actions in conjunction with the actuators assigned according to the need of the situation, this according to the programming logic previously set in the control device. This whole process has been based on chemical and checks performed laboratory equipment, which have been performing manually but that control water before consumption, rationales implementation has been carried out by various control systems that allow the dosages of chemicals are completed accurately and in a timely manner, ensuring that drinking water is at the appropriate levels, and the process to comply mixing chamber can be displayed via an HMI that contains a complete graphical environment of water treatmentEn el bosque protector “Colonso” ubicado en la ciudad del Tena, provincia de Napo, se realizó el presente trabajo de titulación, que concluyó con la automatización de la cámara de mezcla de la planta de tratamiento de agua potable “Colonso”, esto se realizó con el fin de garantizar que el líquido vital que consume la población del cantón Tena este dentro de los parámetros establecidos por la norma INEN 1108. Para ello se implementó varios tipos de sensores que se encargan de dar lecturas de turbiedad y pH que son características propias del agua, estos datos se procesan a través de dispositivos electrónicos, mediante protocolos de comunicación se transforman las señales para que el PLC pueda procesarlas y ejecutar las acciones en conjunto con los actuadores asignados de acuerdo a la necesidad de la situación, esto de acuerdo a la lógica de programación previamente configurada en el dispositivo de control. El proceso, ha estado basado en fundamentaciones químicas y comprobaciones realizadas con equipo de laboratorio, que se han estado realizando manualmente pero que permiten controlar el agua antes del consumo, la implementación se ha llevado a cabo mediante varios sistemas de control, que permiten que las dosificaciones de los químicos se completen de manera precisa y oportuna, garantizando así que el agua de consumo humano se encuentre en los niveles apropiados, además el proceso que cumple la cámara mezcla se podrá visualizar a través de un HMI que contiene un entorno gráfico completo de la planta de tratamiento de agua.Pérez Checa, Aníbal Roberto2016-11-30T16:26:12Z2016-11-30T16:26:12Z2016-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/13080spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:53:08Zoai:dspace.ups.edu.ec:123456789/13080Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:53:08Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse |
| spellingShingle | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. Constante Agualsaca, Andrea Stefania CONTROL AUTOMÁTICO AGUA - PURIFICACIÓN |
| status_str | publishedVersion |
| title | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| title_full | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| title_fullStr | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| title_full_unstemmed | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| title_short | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| title_sort | Investigación, diseño e implementación del control automático de la cámara de mezcla para mejorar la calidad de agua de la planta de potabilización “Colonso”. |
| topic | CONTROL AUTOMÁTICO AGUA - PURIFICACIÓN |
| url | http://dspace.ups.edu.ec/handle/123456789/13080 |