Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio

The present work of investigation evaluated the efficiency of the elimination of the physical-chemical parameters of an activated sludge reactor in which the domestic residual water coming from the Shanshayacu creek in Quitumbe in the south zone of the DMQ was treated. For the development of the pro...

Бүрэн тодорхойлолт

-д хадгалсан:
Номзүйн дэлгэрэнгүй
Үндсэн зохиолч: Crespo Ruiz, Michelle Stefania (author)
Бусад зохиолчид: Martínez Chulde, Diana Lizet (author)
Формат: bachelorThesis
Хэл сонгох:spa
Хэвлэсэн: 2018
Нөхцлүүд:
Онлайн хандалт:http://dspace.ups.edu.ec/handle/123456789/15235
Шошгууд: Шошго нэмэх
Шошго байхгүй, Энэхүү баримтыг шошголох эхний хүн болох!
_version_ 1858988401405984768
author Crespo Ruiz, Michelle Stefania
author2 Martínez Chulde, Diana Lizet
author2_role author
author_facet Crespo Ruiz, Michelle Stefania
Martínez Chulde, Diana Lizet
author_role author
collection Repositorio Universidad Politécnica Salesiana
dc.contributor.none.fl_str_mv Borja Vela, Ximena del Rocío
dc.creator.none.fl_str_mv Crespo Ruiz, Michelle Stefania
Martínez Chulde, Diana Lizet
dc.date.none.fl_str_mv 2018-03-02T22:28:58Z
2018-03-02T22:28:58Z
2018-02
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://dspace.ups.edu.ec/handle/123456789/15235
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Politécnica Salesiana
instname:Universidad Politécnica Salesiana
instacron:UPS
dc.subject.none.fl_str_mv TRATAMIENTO BIOLÓGICO
AGUA - PURIFICACIÓN
dc.title.none.fl_str_mv Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The present work of investigation evaluated the efficiency of the elimination of the physical-chemical parameters of an activated sludge reactor in which the domestic residual water coming from the Shanshayacu creek in Quitumbe in the south zone of the DMQ was treated. For the development of the project, it was essential to know the quality of the wastewater to be treated; the design, construction and operation in the laboratory of the Environmental Engineering Career of the Salesiana Polytechnic University of the complete mixing and continuous flow reactor was carried out which was determined after an analysis, as the best option of the treatment system according to the characteristics of the water. The reactor operated for a period of 56 days; the activated sludge that was used for the process was mature sludge that was obtained from the wastewater treatment plant of the parish of Nono, it was stabilized for a period of 20 days, there was a daily control of certain parameters such as concentration of dissolved oxygen in the mixture liquor with an average value of 5.21 mg / L, the temperature with an average standard variation of 16.39 ° C and the pH whose values were close to neutral. The removal efficiency of the treatment system started with 36.78% of COD and 28% of BOD and ended with 96.08% of COD and 88% of BOD, which determined that the process exceeded the theoretical efficiency by 13, 75%.
eu_rights_str_mv openAccess
format bachelorThesis
id UPS_8d8941f2be8bc9f931ba01eca6d6cf46
instacron_str UPS
institution UPS
instname_str Universidad Politécnica Salesiana
language spa
network_acronym_str UPS
network_name_str Repositorio Universidad Politécnica Salesiana
oai_identifier_str oai:dspace.ups.edu.ec:123456789/15235
publishDate 2018
reponame_str Repositorio Universidad Politécnica Salesiana
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana
repository_id_str 1737
rights_invalid_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
spelling Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorioCrespo Ruiz, Michelle StefaniaMartínez Chulde, Diana LizetTRATAMIENTO BIOLÓGICOAGUA - PURIFICACIÓNThe present work of investigation evaluated the efficiency of the elimination of the physical-chemical parameters of an activated sludge reactor in which the domestic residual water coming from the Shanshayacu creek in Quitumbe in the south zone of the DMQ was treated. For the development of the project, it was essential to know the quality of the wastewater to be treated; the design, construction and operation in the laboratory of the Environmental Engineering Career of the Salesiana Polytechnic University of the complete mixing and continuous flow reactor was carried out which was determined after an analysis, as the best option of the treatment system according to the characteristics of the water. The reactor operated for a period of 56 days; the activated sludge that was used for the process was mature sludge that was obtained from the wastewater treatment plant of the parish of Nono, it was stabilized for a period of 20 days, there was a daily control of certain parameters such as concentration of dissolved oxygen in the mixture liquor with an average value of 5.21 mg / L, the temperature with an average standard variation of 16.39 ° C and the pH whose values were close to neutral. The removal efficiency of the treatment system started with 36.78% of COD and 28% of BOD and ended with 96.08% of COD and 88% of BOD, which determined that the process exceeded the theoretical efficiency by 13, 75%.El presente trabajo de investigación evaluó la eficiencia de remoción de los parámetros físico-químicos de un reactor de lodos activados en el que se trató agua residual doméstica proveniente de la quebrada Shanshayacu ubicada en Quitumbe en la zona sur del DMQ. Para el desarrollo del proyecto fue fundamental conocer la calidad del agua residual a tratar; se llevó a cabo el diseño, la construcción y la operación en el laboratorio de la Carrera de Ingeniería Ambiental de la Universidad Politécnica Salesiana del reactor de mezcla completa y flujo continuo el cual fue determinado luego de un análisis, como mejor opción de sistema de tratamiento según las características del agua. El reactor operó por un periodo de 56 días; el lodo activado que se utilizó para el proceso fue lodo maduro que se obtuvo de la planta de tratamiento de aguas residuales de la parroquia de Nono, éste fue estabilizado por un lapso de 20 días, se tuvo un control diario de ciertos parámetros como la concentración de oxígeno disuelto en el licor de mezcla con un valor promedio de 5,21 mg/L, la temperatura con una media de variación estándar de 16,39 °C y el pH cuyos valores se mantuvieron cercanos al neutro. La eficiencia de remoción del sistema de tratamiento inició con 36,78 % de DQO y 28 % de DBO y finalizó con 96,08% de DQO y 88% de DBO, lo cual determinó que el proceso superó la eficiencia teórica en un 13,75%.Borja Vela, Ximena del Rocío2018-03-02T22:28:58Z2018-03-02T22:28:58Z2018-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/15235spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:52:31Zoai:dspace.ups.edu.ec:123456789/15235Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:52:31Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse
spellingShingle Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
Crespo Ruiz, Michelle Stefania
TRATAMIENTO BIOLÓGICO
AGUA - PURIFICACIÓN
status_str publishedVersion
title Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
title_full Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
title_fullStr Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
title_full_unstemmed Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
title_short Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
title_sort Diseño, construcción y arranque de operación de un reactor de lodos activados a escala de laboratorio
topic TRATAMIENTO BIOLÓGICO
AGUA - PURIFICACIÓN
url http://dspace.ups.edu.ec/handle/123456789/15235