Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011
As is known to the public, mastitis is a problem worldwide, and even more so when it is not detected at the early stages of the infection, this is why research has been carried out focusing on improving the methods used as tools to diagnose the subclinical mastitis, since there is no similar researc...
Saved in:
| Main Author: | |
|---|---|
| Format: | bachelorThesis |
| Language: | spa |
| Published: |
2012
|
| Subjects: | |
| Online Access: | http://dspace.ups.edu.ec/handle/123456789/3730 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1858355709953966080 |
|---|---|
| author | Cruz González, Eloy Guillermo, de la |
| author_facet | Cruz González, Eloy Guillermo, de la |
| author_role | author |
| collection | Repositorio Universidad Politécnica Salesiana |
| dc.contributor.none.fl_str_mv | Contero Callay, Rocío Elizabeth |
| dc.creator.none.fl_str_mv | Cruz González, Eloy Guillermo, de la |
| dc.date.none.fl_str_mv | 2012-07 2013-03-12T18:12:57Z 2013-03-12T18:12:57Z |
| dc.format.none.fl_str_mv | application/pdf application/pdf |
| dc.identifier.none.fl_str_mv | http://dspace.ups.edu.ec/handle/123456789/3730 |
| dc.language.none.fl_str_mv | spa |
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Politécnica Salesiana instname:Universidad Politécnica Salesiana instacron:UPS |
| dc.subject.none.fl_str_mv | AGROPECUARIA CONTROL DE CALIDAD LECHE - ANÁLISIS INDUSTRIA LECHERA MASTITIS BOVINA |
| dc.title.none.fl_str_mv | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | As is known to the public, mastitis is a problem worldwide, and even more so when it is not detected at the early stages of the infection, this is why research has been carried out focusing on improving the methods used as tools to diagnose the subclinical mastitis, since there is no similar research with proper realities, this essay has been developed to provide local data using the available technology in the Laboratory of Milk Quality (LMQ) of the Salesian Polytechnic University, The subject is called “Correlation method California Mastitis Test (CMT), Electric Conductivity (EC) and Somatic Cell Count (SCC) in the Laboratory of Milk Quality of the Salesian Polytechnic University, Cayambe-Ecuador. 2011”, This research was possible thanks to the collaboration of the small producer Association of Pesillo (ATAC-QUEPA), where 41 samples were compiled also to the “La Alegria” and “San Carlos” dairy farms where 32 and 51 samples were taken accordingly, the samples were analyzed at the LMQ, with the purpose of correlating the suggested methods to see if it is possible to predict the SCC through CMT and EC, make a chart where the method values are related, the sensibility of methods CMT and EC regarding SCC, and observe other factors which affect the reading of the researched methods. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UPS_c7eac9e053e00a8788cf8e902274cef8 |
| instacron_str | UPS |
| institution | UPS |
| instname_str | Universidad Politécnica Salesiana |
| language | spa |
| network_acronym_str | UPS |
| network_name_str | Repositorio Universidad Politécnica Salesiana |
| oai_identifier_str | oai:dspace.ups.edu.ec:123456789/3730 |
| publishDate | 2012 |
| reponame_str | Repositorio Universidad Politécnica Salesiana |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana |
| repository_id_str | 1737 |
| spelling | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011Cruz González, Eloy Guillermo, de laAGROPECUARIACONTROL DE CALIDADLECHE - ANÁLISISINDUSTRIA LECHERAMASTITIS BOVINAAs is known to the public, mastitis is a problem worldwide, and even more so when it is not detected at the early stages of the infection, this is why research has been carried out focusing on improving the methods used as tools to diagnose the subclinical mastitis, since there is no similar research with proper realities, this essay has been developed to provide local data using the available technology in the Laboratory of Milk Quality (LMQ) of the Salesian Polytechnic University, The subject is called “Correlation method California Mastitis Test (CMT), Electric Conductivity (EC) and Somatic Cell Count (SCC) in the Laboratory of Milk Quality of the Salesian Polytechnic University, Cayambe-Ecuador. 2011”, This research was possible thanks to the collaboration of the small producer Association of Pesillo (ATAC-QUEPA), where 41 samples were compiled also to the “La Alegria” and “San Carlos” dairy farms where 32 and 51 samples were taken accordingly, the samples were analyzed at the LMQ, with the purpose of correlating the suggested methods to see if it is possible to predict the SCC through CMT and EC, make a chart where the method values are related, the sensibility of methods CMT and EC regarding SCC, and observe other factors which affect the reading of the researched methods.Como es de conocimiento público la mastitis es un problema mundial, y más aun cuando ésta, no es detectada en sus inicios de la infección, por lo que sean enfocado muchos estudios tratando de afinar mejor los métodos utilizados como herramientas para el diagnóstico de la mastitis subclínica, al no tener estudios similares con realidades propias, se ha planteado realizar este ensayo con el fin de proporcionar datos locales utilizando la tecnología disponible en el Laboratorio de Calidad de Leche (LCL) de la Universidad Politécnica Salesiana para estos fines, el tema se titula “Correlación de los métodos California Mastitis Test (CMT), Conductividad Eléctrica (CE) y Conteo de Células Somáticas (CCS) en el Laboratorio de Calidad de Leche de la Universidad Politécnica Salesiana, Cayambe – Ecuador. 2011”, este estudio fue posible gracias a la colaboración de la Asociación de pequeños productores de Pesillo (ATAC-QUEPA), donde se recopiló 41 muestras y en las haciendas “La Alegría” y “San Carlos”, donde se tomó 32 y 51 muestras respectivamente, las muestras fueron analizadas en LCL, con el propósito de correlacionar los métodos propuestos para ver si hay la posibilidad de predecir el CCS mediante CMT y CE, sacar un cuadro donde se relacionen los valores de los métodos, la sensibilidad de los métodos CMT y CE con respecto al CCS y observar otros factores que afecten la lectura de los métodos estudiados.Contero Callay, Rocío Elizabeth2013-03-12T18:12:57Z2013-03-12T18:12:57Z2012-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/3730spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2020-05-15T22:32:38Zoai:dspace.ups.edu.ec:123456789/3730Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372020-05-15T22:32:38Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse |
| spellingShingle | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 Cruz González, Eloy Guillermo, de la AGROPECUARIA CONTROL DE CALIDAD LECHE - ANÁLISIS INDUSTRIA LECHERA MASTITIS BOVINA |
| status_str | publishedVersion |
| title | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| title_full | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| title_fullStr | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| title_full_unstemmed | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| title_short | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| title_sort | Correlación de los métodos California Mastitis Test (CMT), conductividad eléctrica (CE) y conteo de células somáticas (CCS) en el laboratorio de calidad de leche de la Universidad Politécnica Salesiana, Cayambe - Ecuador. 2011 |
| topic | AGROPECUARIA CONTROL DE CALIDAD LECHE - ANÁLISIS INDUSTRIA LECHERA MASTITIS BOVINA |
| url | http://dspace.ups.edu.ec/handle/123456789/3730 |