Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001

ENERGYPETROL is an Ecuadorian company that has 15 years of experience in the design and construction of fire and gas detection systems, in which one of the ways to suppress fire is through the application of clean extinguishing agents such as FM- 200, for which it is necessary to carry out a leakpro...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autor principal: Cahuasquí Molina, Jonathan Moises (author)
Format: bachelorThesis
Idioma:spa
Publicat: 2017
Matèries:
Accés en línia:http://dspace.ups.edu.ec/handle/123456789/14019
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
_version_ 1858988367670149120
author Cahuasquí Molina, Jonathan Moises
author_facet Cahuasquí Molina, Jonathan Moises
author_role author
collection Repositorio Universidad Politécnica Salesiana
dc.contributor.none.fl_str_mv Celi Sánchez, Carmen Johanna
dc.creator.none.fl_str_mv Cahuasquí Molina, Jonathan Moises
dc.date.none.fl_str_mv 2017-04-13T15:35:11Z
2017-04-13T15:35:11Z
2017-02
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://dspace.ups.edu.ec/handle/123456789/14019
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Politécnica Salesiana
instname:Universidad Politécnica Salesiana
instacron:UPS
dc.subject.none.fl_str_mv PROGRAMAS PARA COMPUTADOR
FABRICAS - PROTECCIÓN
PREVENCIÓN DE INCENCIOS
EXTINCIÓN DE INCENDIOS
dc.title.none.fl_str_mv Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description ENERGYPETROL is an Ecuadorian company that has 15 years of experience in the design and construction of fire and gas detection systems, in which one of the ways to suppress fire is through the application of clean extinguishing agents such as FM- 200, for which it is necessary to carry out a leakproofness test at the location. The ENERGYPETROL company sponsors the development of an automatic, modular and portable system which allows the leakage tests to be carried out in order to verify, certify and locate leaks in the enclosure, in order to verify if it is sufficiently closed to keep Extinguishing agent for a certain time and in the percentage of concentration of design that guarantees the fire extinction, all this process is established by the norm NFPA 2001 that tries to determine the leakages using a door fan, which allows to emulate the conditions of a Discharge of the fire system, obtaining and recording flow and pressure variables in order to predict the establishment time that the extinguishing agent will remain in the location. The results of these tests through a technical report validate to the client that the location is adequate to apply the extinguishing agent, guaranteeing the protection of the fire system in a real fire alarm, in addition to collaborating with the conservation of the environment.
eu_rights_str_mv openAccess
format bachelorThesis
id UPS_d0ee5e2d7e3e829d009a8ee058aaf1bc
instacron_str UPS
institution UPS
instname_str Universidad Politécnica Salesiana
language spa
network_acronym_str UPS
network_name_str Repositorio Universidad Politécnica Salesiana
oai_identifier_str oai:dspace.ups.edu.ec:123456789/14019
publishDate 2017
reponame_str Repositorio Universidad Politécnica Salesiana
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana
repository_id_str 1737
spelling Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001Cahuasquí Molina, Jonathan MoisesPROGRAMAS PARA COMPUTADORFABRICAS - PROTECCIÓNPREVENCIÓN DE INCENCIOSEXTINCIÓN DE INCENDIOSENERGYPETROL is an Ecuadorian company that has 15 years of experience in the design and construction of fire and gas detection systems, in which one of the ways to suppress fire is through the application of clean extinguishing agents such as FM- 200, for which it is necessary to carry out a leakproofness test at the location. The ENERGYPETROL company sponsors the development of an automatic, modular and portable system which allows the leakage tests to be carried out in order to verify, certify and locate leaks in the enclosure, in order to verify if it is sufficiently closed to keep Extinguishing agent for a certain time and in the percentage of concentration of design that guarantees the fire extinction, all this process is established by the norm NFPA 2001 that tries to determine the leakages using a door fan, which allows to emulate the conditions of a Discharge of the fire system, obtaining and recording flow and pressure variables in order to predict the establishment time that the extinguishing agent will remain in the location. The results of these tests through a technical report validate to the client that the location is adequate to apply the extinguishing agent, guaranteeing the protection of the fire system in a real fire alarm, in addition to collaborating with the conservation of the environment.ENERGYPETROL es una empresa Ecuatoriana que tiene 15 años de experiencia en diseño y construcción de sistemas de detección de fuego y gas, dentro de los cuales, una de las maneras de suprimir el fuego es mediante la aplicación de agentes extintores limpios como el denominado FM-200, para lo cual es necesario realizar una prueba de estanqueidad en la locación. La empresa ENERGYPETROL auspicia el desarrollo de un sistema automático, modular y portátil el cual permita realizar las pruebas de estanqueidad con el fin de comprobar, certificar y localizar fugas en el recinto, con objeto de verificar si es lo suficientemente cerrado para mantener dentro, al agente extintor por un tiempo determinado y en el porcentaje de concentración de diseño que garantiza la extinción del fuego, todo este proceso está establecido por la norma NFPA 2001 que pretende determinar las fugas utilizando un ventilador de puerta, el cual permita emular las condiciones de una descarga real del sistema contra incendios, obteniendo y registrando variables de flujo y presión con el fin de predecir el tiempo de establecimiento que permanecerá el agente extintor en la locación. Los resultados de estas pruebas mediante un informe técnico validan ante el cliente que la locación es adecuada para aplicar el agente extintor, garantizando la protección del sistema contra incendios en una alarma de fuego real, además colaborando con la conservación del medio ambiente.Celi Sánchez, Carmen Johanna2017-04-13T15:35:11Z2017-04-13T15:35:11Z2017-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/14019spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:53:04Zoai:dspace.ups.edu.ec:123456789/14019Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:53:04Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse
spellingShingle Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
Cahuasquí Molina, Jonathan Moises
PROGRAMAS PARA COMPUTADOR
FABRICAS - PROTECCIÓN
PREVENCIÓN DE INCENCIOS
EXTINCIÓN DE INCENDIOS
status_str publishedVersion
title Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
title_full Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
title_fullStr Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
title_full_unstemmed Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
title_short Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
title_sort Diseño y construcción de un sistema portátil de pruebas de estanqueidad para locaciones cerradas, en base a las exigencias de la norma NFPA 2001
topic PROGRAMAS PARA COMPUTADOR
FABRICAS - PROTECCIÓN
PREVENCIÓN DE INCENCIOS
EXTINCIÓN DE INCENDIOS
url http://dspace.ups.edu.ec/handle/123456789/14019