Ubicación óptima de unidades de medición fasorial en sistemas de transmisión

In power transmission systems is necessary control and monitoring the parameters of the power grid, for which they are implementing smart grids. These units Phasor measurement systems PMU's allow a better observability of power system by the current and voltage parameters the phasor measurement...

Πλήρης περιγραφή

Αποθηκεύτηκε σε:
Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριος συγγραφέας: Peláez Mejía, Oswaldo Fernando (author)
Άλλοι συγγραφείς: Toapanta Narvaez, Danny Miguel (author)
Μορφή: bachelorThesis
Γλώσσα:spa
Έκδοση: 2015
Θέματα:
Διαθέσιμο Online:http://dspace.ups.edu.ec/handle/123456789/11298
Ετικέτες: Προσθήκη ετικέτας
Δεν υπάρχουν, Καταχωρήστε ετικέτα πρώτοι!
_version_ 1839327023651094528
author Peláez Mejía, Oswaldo Fernando
author2 Toapanta Narvaez, Danny Miguel
author2_role author
author_facet Peláez Mejía, Oswaldo Fernando
Toapanta Narvaez, Danny Miguel
author_role author
collection Repositorio Universidad Politécnica Salesiana
dc.contributor.none.fl_str_mv Carrión Galarza, Diego Francisco
dc.creator.none.fl_str_mv Peláez Mejía, Oswaldo Fernando
Toapanta Narvaez, Danny Miguel
dc.date.none.fl_str_mv 2015-11
2016-01-09T15:41:38Z
2016-01-09T15:41:38Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://dspace.ups.edu.ec/handle/123456789/11298
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Politécnica Salesiana
instname:Universidad Politécnica Salesiana
instacron:UPS
dc.subject.none.fl_str_mv INGENIERÍA ELÉCTRICA
CONSUMO DE ENERGÍA ELÉCTRICA
TRANSMISIÓN DE ENERGÍA ELÉCTRICA
DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
dc.title.none.fl_str_mv Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description In power transmission systems is necessary control and monitoring the parameters of the power grid, for which they are implementing smart grids. These units Phasor measurement systems PMU's allow a better observability of power system by the current and voltage parameters the phasor measurement in real time stamp, providing new possibilities for analysis and control of electric transmission systems. The PMU's location in all transmission system bus is economically unviable therefore need to optimize its location giving you an observability of the system with the least number of PMU's depending on the system being controlled. This paper proposes the optimal PMU's location in transmission systems, for it describes and applies a couple of methods in order to determine the phasor measurement unit optimal placement in the power transmission system. The problem is posed in seeking maximum observability of the transmission system with the minimum equipment, which is solved using a mathematical lineal integer programming model and Greedy heuristic model developed with a mathematic software algorithm so that is observed and compared these two methods on the 230 kV Ecuador national transmission system.
eu_rights_str_mv openAccess
format bachelorThesis
id UPS_dc5c81b105712b99ef9d04656fbf3bc2
instacron_str UPS
institution UPS
instname_str Universidad Politécnica Salesiana
language spa
network_acronym_str UPS
network_name_str Repositorio Universidad Politécnica Salesiana
oai_identifier_str oai:dspace.ups.edu.ec:123456789/11298
publishDate 2015
reponame_str Repositorio Universidad Politécnica Salesiana
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana
repository_id_str 1737
spelling Ubicación óptima de unidades de medición fasorial en sistemas de transmisiónPeláez Mejía, Oswaldo FernandoToapanta Narvaez, Danny MiguelINGENIERÍA ELÉCTRICACONSUMO DE ENERGÍA ELÉCTRICATRANSMISIÓN DE ENERGÍA ELÉCTRICADISTRIBUCIÓN DE ENERGÍA ELÉCTRICAIn power transmission systems is necessary control and monitoring the parameters of the power grid, for which they are implementing smart grids. These units Phasor measurement systems PMU's allow a better observability of power system by the current and voltage parameters the phasor measurement in real time stamp, providing new possibilities for analysis and control of electric transmission systems. The PMU's location in all transmission system bus is economically unviable therefore need to optimize its location giving you an observability of the system with the least number of PMU's depending on the system being controlled. This paper proposes the optimal PMU's location in transmission systems, for it describes and applies a couple of methods in order to determine the phasor measurement unit optimal placement in the power transmission system. The problem is posed in seeking maximum observability of the transmission system with the minimum equipment, which is solved using a mathematical lineal integer programming model and Greedy heuristic model developed with a mathematic software algorithm so that is observed and compared these two methods on the 230 kV Ecuador national transmission system.En los sistemas de transmisión de energía eléctrica es necesario el control y supervisión de los parámetros de la red de potencia, para lo cual se están implementando las redes inteligentes. Dentro de esos sistemas se encuentran las Unidades de Medición Fasorial PMU’s, que permiten obtener una mejor observabilidad del sistema eléctrico de potencia, mediante la medición fasorial de los parámetros de corriente y voltaje en tiempo real, brindando nuevas posibilidades para el análisis y control de los sistemas de transmisión de energía eléctrica. La ubicación de PMU’s en todas las barras de un sistema de transmisión es económicamente inviable por ello la necesidad de optimizar su ubicación permitiendo obtener una observabilidad del sistema con el menor número de PMU’s dependiendo del sistema a controlar. La presente documento propone la ubicación optima de PMU’s en el sistemas de transmisión, para ello se describe y aplica un par de metodologías de manera de determinar la ubicación óptima de las unidades de medida fasorial en el sistema de transmisión eléctrica. El problema está planteado en buscar la máxima observabilidad del sistema de transmisión con el mínimo de equipos, el cual es solucionado empleando un modelo matemático de programación entera lineal y el modelo heurístico de Greedy desarrollado con un algoritmo en software matemático, de modo que se observa y compara estas dos metodologías sobre el Sistema Nacional Interconectado de Transmisión de 230 kV del Ecuador.Carrión Galarza, Diego Francisco2016-01-09T15:41:38Z2016-01-09T15:41:38Z2015-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/11298spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:52:52Zoai:dspace.ups.edu.ec:123456789/11298Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:52:52Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse
spellingShingle Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
Peláez Mejía, Oswaldo Fernando
INGENIERÍA ELÉCTRICA
CONSUMO DE ENERGÍA ELÉCTRICA
TRANSMISIÓN DE ENERGÍA ELÉCTRICA
DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
status_str publishedVersion
title Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
title_full Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
title_fullStr Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
title_full_unstemmed Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
title_short Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
title_sort Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
topic INGENIERÍA ELÉCTRICA
CONSUMO DE ENERGÍA ELÉCTRICA
TRANSMISIÓN DE ENERGÍA ELÉCTRICA
DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA
url http://dspace.ups.edu.ec/handle/123456789/11298