Ubicación óptima de unidades de medición fasorial en sistemas de transmisión
In power transmission systems is necessary control and monitoring the parameters of the power grid, for which they are implementing smart grids. These units Phasor measurement systems PMU's allow a better observability of power system by the current and voltage parameters the phasor measurement...
Αποθηκεύτηκε σε:
Κύριος συγγραφέας: | |
---|---|
Άλλοι συγγραφείς: | |
Μορφή: | bachelorThesis |
Γλώσσα: | spa |
Έκδοση: |
2015
|
Θέματα: | |
Διαθέσιμο Online: | http://dspace.ups.edu.ec/handle/123456789/11298 |
Ετικέτες: |
Προσθήκη ετικέτας
Δεν υπάρχουν, Καταχωρήστε ετικέτα πρώτοι!
|
_version_ | 1839327023651094528 |
---|---|
author | Peláez Mejía, Oswaldo Fernando |
author2 | Toapanta Narvaez, Danny Miguel |
author2_role | author |
author_facet | Peláez Mejía, Oswaldo Fernando Toapanta Narvaez, Danny Miguel |
author_role | author |
collection | Repositorio Universidad Politécnica Salesiana |
dc.contributor.none.fl_str_mv | Carrión Galarza, Diego Francisco |
dc.creator.none.fl_str_mv | Peláez Mejía, Oswaldo Fernando Toapanta Narvaez, Danny Miguel |
dc.date.none.fl_str_mv | 2015-11 2016-01-09T15:41:38Z 2016-01-09T15:41:38Z |
dc.format.none.fl_str_mv | application/pdf |
dc.identifier.none.fl_str_mv | http://dspace.ups.edu.ec/handle/123456789/11298 |
dc.language.none.fl_str_mv | spa |
dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess |
dc.source.none.fl_str_mv | reponame:Repositorio Universidad Politécnica Salesiana instname:Universidad Politécnica Salesiana instacron:UPS |
dc.subject.none.fl_str_mv | INGENIERÍA ELÉCTRICA CONSUMO DE ENERGÍA ELÉCTRICA TRANSMISIÓN DE ENERGÍA ELÉCTRICA DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA |
dc.title.none.fl_str_mv | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
description | In power transmission systems is necessary control and monitoring the parameters of the power grid, for which they are implementing smart grids. These units Phasor measurement systems PMU's allow a better observability of power system by the current and voltage parameters the phasor measurement in real time stamp, providing new possibilities for analysis and control of electric transmission systems. The PMU's location in all transmission system bus is economically unviable therefore need to optimize its location giving you an observability of the system with the least number of PMU's depending on the system being controlled. This paper proposes the optimal PMU's location in transmission systems, for it describes and applies a couple of methods in order to determine the phasor measurement unit optimal placement in the power transmission system. The problem is posed in seeking maximum observability of the transmission system with the minimum equipment, which is solved using a mathematical lineal integer programming model and Greedy heuristic model developed with a mathematic software algorithm so that is observed and compared these two methods on the 230 kV Ecuador national transmission system. |
eu_rights_str_mv | openAccess |
format | bachelorThesis |
id | UPS_dc5c81b105712b99ef9d04656fbf3bc2 |
instacron_str | UPS |
institution | UPS |
instname_str | Universidad Politécnica Salesiana |
language | spa |
network_acronym_str | UPS |
network_name_str | Repositorio Universidad Politécnica Salesiana |
oai_identifier_str | oai:dspace.ups.edu.ec:123456789/11298 |
publishDate | 2015 |
reponame_str | Repositorio Universidad Politécnica Salesiana |
repository.mail.fl_str_mv | . |
repository.name.fl_str_mv | Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana |
repository_id_str | 1737 |
spelling | Ubicación óptima de unidades de medición fasorial en sistemas de transmisiónPeláez Mejía, Oswaldo FernandoToapanta Narvaez, Danny MiguelINGENIERÍA ELÉCTRICACONSUMO DE ENERGÍA ELÉCTRICATRANSMISIÓN DE ENERGÍA ELÉCTRICADISTRIBUCIÓN DE ENERGÍA ELÉCTRICAIn power transmission systems is necessary control and monitoring the parameters of the power grid, for which they are implementing smart grids. These units Phasor measurement systems PMU's allow a better observability of power system by the current and voltage parameters the phasor measurement in real time stamp, providing new possibilities for analysis and control of electric transmission systems. The PMU's location in all transmission system bus is economically unviable therefore need to optimize its location giving you an observability of the system with the least number of PMU's depending on the system being controlled. This paper proposes the optimal PMU's location in transmission systems, for it describes and applies a couple of methods in order to determine the phasor measurement unit optimal placement in the power transmission system. The problem is posed in seeking maximum observability of the transmission system with the minimum equipment, which is solved using a mathematical lineal integer programming model and Greedy heuristic model developed with a mathematic software algorithm so that is observed and compared these two methods on the 230 kV Ecuador national transmission system.En los sistemas de transmisión de energía eléctrica es necesario el control y supervisión de los parámetros de la red de potencia, para lo cual se están implementando las redes inteligentes. Dentro de esos sistemas se encuentran las Unidades de Medición Fasorial PMU’s, que permiten obtener una mejor observabilidad del sistema eléctrico de potencia, mediante la medición fasorial de los parámetros de corriente y voltaje en tiempo real, brindando nuevas posibilidades para el análisis y control de los sistemas de transmisión de energía eléctrica. La ubicación de PMU’s en todas las barras de un sistema de transmisión es económicamente inviable por ello la necesidad de optimizar su ubicación permitiendo obtener una observabilidad del sistema con el menor número de PMU’s dependiendo del sistema a controlar. La presente documento propone la ubicación optima de PMU’s en el sistemas de transmisión, para ello se describe y aplica un par de metodologías de manera de determinar la ubicación óptima de las unidades de medida fasorial en el sistema de transmisión eléctrica. El problema está planteado en buscar la máxima observabilidad del sistema de transmisión con el mínimo de equipos, el cual es solucionado empleando un modelo matemático de programación entera lineal y el modelo heurístico de Greedy desarrollado con un algoritmo en software matemático, de modo que se observa y compara estas dos metodologías sobre el Sistema Nacional Interconectado de Transmisión de 230 kV del Ecuador.Carrión Galarza, Diego Francisco2016-01-09T15:41:38Z2016-01-09T15:41:38Z2015-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/11298spainfo:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:52:52Zoai:dspace.ups.edu.ec:123456789/11298Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:52:52Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse |
spellingShingle | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión Peláez Mejía, Oswaldo Fernando INGENIERÍA ELÉCTRICA CONSUMO DE ENERGÍA ELÉCTRICA TRANSMISIÓN DE ENERGÍA ELÉCTRICA DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA |
status_str | publishedVersion |
title | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
title_full | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
title_fullStr | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
title_full_unstemmed | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
title_short | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
title_sort | Ubicación óptima de unidades de medición fasorial en sistemas de transmisión |
topic | INGENIERÍA ELÉCTRICA CONSUMO DE ENERGÍA ELÉCTRICA TRANSMISIÓN DE ENERGÍA ELÉCTRICA DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA |
url | http://dspace.ups.edu.ec/handle/123456789/11298 |