Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV

The following investigation consists on the obtention of water type IV. In order to get of distilled water, a balance of energy considering heat flows involved between water tanks and cover was presented. Afterwards, current formula was used to develop calculations explaining every process of simpli...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Luna Peñafiel, Jonathan Fabricio (author)
Weitere Verfasser: Ruiz Antamba, Lizeth Andrea (author)
Format: bachelorThesis
Sprache:spa
Veröffentlicht: 2017
Schlagworte:
Online Zugang:http://dspace.ups.edu.ec/handle/123456789/14493
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1858988470775578624
author Luna Peñafiel, Jonathan Fabricio
author2 Ruiz Antamba, Lizeth Andrea
author2_role author
author_facet Luna Peñafiel, Jonathan Fabricio
Ruiz Antamba, Lizeth Andrea
author_role author
collection Repositorio Universidad Politécnica Salesiana
dc.contributor.none.fl_str_mv Quitiaquez Sarzosa, William Giovanny
dc.creator.none.fl_str_mv Luna Peñafiel, Jonathan Fabricio
Ruiz Antamba, Lizeth Andrea
dc.date.none.fl_str_mv 2017-08-04T19:46:03Z
2017-08-04T19:46:03Z
2017-07
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://dspace.ups.edu.ec/handle/123456789/14493
dc.language.none.fl_str_mv spa
dc.rights.none.fl_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Politécnica Salesiana
instname:Universidad Politécnica Salesiana
instacron:UPS
dc.subject.none.fl_str_mv DESTILACIÓN
AGUA DESTILADA
BALANCE TÉRMICO
ENERGÍA SOLAR
dc.title.none.fl_str_mv Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The following investigation consists on the obtention of water type IV. In order to get of distilled water, a balance of energy considering heat flows involved between water tanks and cover was presented. Afterwards, current formula was used to develop calculations explaining every process of simplification or replacement, making them more concise in their structure. Equipment performance tests were carried out for an extended period of time in favorable conditions such as sunny days as well as in unfavorable conditions such as rainy days. The gathered data corroborated the foreseen energy balance obtaining , making its industrial investment profitable. Moreover, its consume was considerably low in comparison to electric distillers, which is why the equipment is eco-friendly. In relation to the radiation incident in different days, while it has a high value, temperatures in water are superior to 70 °C, same situation happens with the absorbent plate and the glass cover, which temperatures rise as the following: the former exceeds temperatures of 85 °C and the later maintains its rage from 40 °C to 50 °C. In this conditions, 60 ml of water can be obtained in approximately 20 minutes. On the contrary, in days with low radiation, values in water, absorbent plate and glass cover drop to 27 °C, 30 °C and 20 °C respectively, getting on average 10 ml of distilled water every 20 minutes. The cascade type distillation design in comparison to distillation results reached by Tabuada and Flores, shows a compact size that allows the prompt heat absorption obtaining a higher quantity of distillation in a shorter period of time; its yield is 61% while the performance of the double deck design is 35%
eu_rights_str_mv openAccess
format bachelorThesis
id UPS_e8d98bb0205bdde38c0ec4e92c69e958
instacron_str UPS
institution UPS
instname_str Universidad Politécnica Salesiana
language spa
network_acronym_str UPS
network_name_str Repositorio Universidad Politécnica Salesiana
oai_identifier_str oai:dspace.ups.edu.ec:123456789/14493
publishDate 2017
reponame_str Repositorio Universidad Politécnica Salesiana
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana
repository_id_str 1737
rights_invalid_str_mv Atribución-NoComercial-SinDerivadas 3.0 Ecuador
http://creativecommons.org/licenses/by-nc-nd/3.0/ec/
spelling Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IVLuna Peñafiel, Jonathan FabricioRuiz Antamba, Lizeth AndreaDESTILACIÓNAGUA DESTILADABALANCE TÉRMICOENERGÍA SOLARThe following investigation consists on the obtention of water type IV. In order to get of distilled water, a balance of energy considering heat flows involved between water tanks and cover was presented. Afterwards, current formula was used to develop calculations explaining every process of simplification or replacement, making them more concise in their structure. Equipment performance tests were carried out for an extended period of time in favorable conditions such as sunny days as well as in unfavorable conditions such as rainy days. The gathered data corroborated the foreseen energy balance obtaining , making its industrial investment profitable. Moreover, its consume was considerably low in comparison to electric distillers, which is why the equipment is eco-friendly. In relation to the radiation incident in different days, while it has a high value, temperatures in water are superior to 70 °C, same situation happens with the absorbent plate and the glass cover, which temperatures rise as the following: the former exceeds temperatures of 85 °C and the later maintains its rage from 40 °C to 50 °C. In this conditions, 60 ml of water can be obtained in approximately 20 minutes. On the contrary, in days with low radiation, values in water, absorbent plate and glass cover drop to 27 °C, 30 °C and 20 °C respectively, getting on average 10 ml of distilled water every 20 minutes. The cascade type distillation design in comparison to distillation results reached by Tabuada and Flores, shows a compact size that allows the prompt heat absorption obtaining a higher quantity of distillation in a shorter period of time; its yield is 61% while the performance of the double deck design is 35%La presente investigación consiste en la obtención de agua tipo IV, se plantea obtener de agua destilada, se presenta un balance de energía considerando todos los flujos de calor involucrados entre los depósitos de agua y la cubierta, posterior a esto se desarrolló los cálculos rigurosamente mediante el uso de fórmulas actuales, explicando todo proceso de simplificación o reemplazo, haciéndolas más concisas en su estructura. Las pruebas de funcionamiento del equipo fueron realizadas durante un período prolongado de tiempo, en condiciones favorables como días soleados, y condiciones desfavorables con leves lloviznas, los datos arrojados corroboraron el balance de energía previsto llegando a obtener haciendo rentable su inversión a nivel industrial, además de tener un consumo de , valor que es sumamente inferior en comparación con los destiladores eléctricos, por lo cual el equipo es amigable con el medio ambiente. En relación con la radiación incidente en diferentes días, mientras esta posea un valor alto, se llega a tener temperaturas superiores a los 70°C en el agua, mientras que la placa absorbente supera los 85°C, así mismo la cubierta de vidrio se encuentra en un rango 40°C a 50°C, llegando a obtener de agua destilada en aproximadamente 20 minutos a diferencia de los días con baja radiación, donde estos valores descienden a 27°C, 30°C, y 20°C respectivamente, recolectando un promedio de de agua destilada cada 20 minutos. El diseño de destilación tipo cascada en comparación con los resultados de destilación obtenidos por Tabuada y Flores, presenta un tamaño compacto logrando que la absorción de calor sea inmediata obteniendo mayor cantidad de destilación, en menos tiempo, su rendimiento es del 61% mientras que el de doble cubierta presenta una eficiencia del 35%Quitiaquez Sarzosa, William Giovanny2017-08-04T19:46:03Z2017-08-04T19:46:03Z2017-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfhttp://dspace.ups.edu.ec/handle/123456789/14493spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:53:18Zoai:dspace.ups.edu.ec:123456789/14493Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:53:18Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse
spellingShingle Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
Luna Peñafiel, Jonathan Fabricio
DESTILACIÓN
AGUA DESTILADA
BALANCE TÉRMICO
ENERGÍA SOLAR
status_str publishedVersion
title Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
title_full Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
title_fullStr Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
title_full_unstemmed Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
title_short Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
title_sort Diseño y construcción de un sistema de destilación solar tipo cascada para la obtención de 180 ml/día de agua destilada tipo IV
topic DESTILACIÓN
AGUA DESTILADA
BALANCE TÉRMICO
ENERGÍA SOLAR
url http://dspace.ups.edu.ec/handle/123456789/14493