Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución
The document presents an optimal location of distributed generation units (DG) based on unbalanced three phase fault analysis. Unbalanced faults can be classified in line-to-earth fault, line-to-line fault and two lines-to-earth to ground fault. Additionally, another restriction is associated with v...
Shranjeno v:
| Glavni avtor: | |
|---|---|
| Format: | bachelorThesis |
| Jezik: | spa |
| Izdano: |
2018
|
| Teme: | |
| Online dostop: | http://dspace.ups.edu.ec/handle/123456789/14997 |
| Oznake: |
Označite
Brez oznak, prvi označite!
|
| _version_ | 1863428256304201728 |
|---|---|
| author | Burbano Vásquez, Byron Andrés |
| author_facet | Burbano Vásquez, Byron Andrés |
| author_role | author |
| collection | Repositorio Universidad Politécnica Salesiana |
| dc.contributor.none.fl_str_mv | Valenzuela Santillán, Alex David |
| dc.creator.none.fl_str_mv | Burbano Vásquez, Byron Andrés |
| dc.date.none.fl_str_mv | 2018-01-18T16:41:07Z 2018-01-18T16:41:07Z 2018-01 |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | Burbano Vásquez, B. A. (2018). Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución. Universidad Politécnica Salesiana. Carrera de Ingeniería Eléctrica. Sede Quito UPS-KT01462 http://dspace.ups.edu.ec/handle/123456789/14997 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Universidad Politécnica Salesiana. Carrera de Ingeniería Eléctrica. Sede Quito |
| dc.rights.none.fl_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Politécnica Salesiana instname:Universidad Politécnica Salesiana instacron:UPS |
| dc.subject.none.fl_str_mv | INGENIERÍA ELÉCTRICA DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA ENERGÍA ELÉCTRICA SISTEMAS DE ENERGÍA ELÉCTRICA CORTOCIRCUITOS |
| dc.title.none.fl_str_mv | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | The document presents an optimal location of distributed generation units (DG) based on unbalanced three phase fault analysis. Unbalanced faults can be classified in line-to-earth fault, line-to-line fault and two lines-to-earth to ground fault. Additionally, another restriction is associated with voltage drop in the entire network. The deployment of DG units into the distribution grid will modify the network´s topology, and thus, large short-circuit currents will flow from generator terminals into the fault. Set in this context, the restriction associated with the deployment of DG is based on that short circuit interrupting devices such as circuit breakers, disconnectors and fuses should operate within their ratings. The proposed methodology is implemented in the IEEE radial distribution test feeder. The first scenario considers a traditional network, in these scenario no introduction of distributed generation. This scenario establishes the short-circuit currents, that are used as preliminary values to determine the system's restrictions. The second scenario contemplates the deployment of DG based on a mathematical model, which considers the restrictions imposed by the initial system (nominal rating of power components). The results permit to determine the optimal placement of DG that satisfy with all restrictions, and optimize the operation of the distribution system. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UPS_eaee4ef671f65394af419c56943d9ccf |
| identifier_str_mv | Burbano Vásquez, B. A. (2018). Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución. Universidad Politécnica Salesiana. Carrera de Ingeniería Eléctrica. Sede Quito UPS-KT01462 |
| instacron_str | UPS |
| institution | UPS |
| instname_str | Universidad Politécnica Salesiana |
| language | spa |
| network_acronym_str | UPS |
| network_name_str | Repositorio Universidad Politécnica Salesiana |
| oai_identifier_str | oai:dspace.ups.edu.ec:123456789/14997 |
| publishDate | 2018 |
| publisher.none.fl_str_mv | Universidad Politécnica Salesiana. Carrera de Ingeniería Eléctrica. Sede Quito |
| reponame_str | Repositorio Universidad Politécnica Salesiana |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesiana |
| repository_id_str | 1737 |
| rights_invalid_str_mv | Atribución-NoComercial-SinDerivadas 3.0 Ecuador http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ |
| spelling | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribuciónBurbano Vásquez, Byron AndrésINGENIERÍA ELÉCTRICADISTRIBUCIÓN DE ENERGÍA ELÉCTRICAENERGÍA ELÉCTRICASISTEMAS DE ENERGÍA ELÉCTRICACORTOCIRCUITOSThe document presents an optimal location of distributed generation units (DG) based on unbalanced three phase fault analysis. Unbalanced faults can be classified in line-to-earth fault, line-to-line fault and two lines-to-earth to ground fault. Additionally, another restriction is associated with voltage drop in the entire network. The deployment of DG units into the distribution grid will modify the network´s topology, and thus, large short-circuit currents will flow from generator terminals into the fault. Set in this context, the restriction associated with the deployment of DG is based on that short circuit interrupting devices such as circuit breakers, disconnectors and fuses should operate within their ratings. The proposed methodology is implemented in the IEEE radial distribution test feeder. The first scenario considers a traditional network, in these scenario no introduction of distributed generation. This scenario establishes the short-circuit currents, that are used as preliminary values to determine the system's restrictions. The second scenario contemplates the deployment of DG based on a mathematical model, which considers the restrictions imposed by the initial system (nominal rating of power components). The results permit to determine the optimal placement of DG that satisfy with all restrictions, and optimize the operation of the distribution system.El presente documento propone un método de localización óptima de unidades de generación distribuida (GD) en base al análisis de fallas de manera que se mantengan las condiciones de operación del sistema. Además, la función objetivo está sujeta a un control de los niveles de voltaje y potencia, siendo estas las restricciones consideradas para la optimización del sistema. El despliegue de unidades de generación en el sistema de distribución modificará la topología de la red, influyendo directamente en las corrientes de cortocircuito, por tanto se debe considerar como un importante factor la capacidad nominal de todos los elementos que comprenden la red, tales como disyuntores, seccionadores y conductores. Para implementar la metodología propuesta se realiza el análisis en el sistema de 13 barras de la IEEE para sistemas de distribución, en base a dos escenarios. El primer escenario no considera la introducción de GD, con lo cual se establece las corrientes de cortocircuito, que sirven como valores preliminares para determinar las restricciones del sistema, El segundo escenario contempla la implementación del modelo matemático propuesto para el despliegue de GD considerando las restricciones impuestas por el sistema inicial. Los resultados permiten determinar los puntos de localización de generación que cumplen con todas las restricciones, y que optimizan la operación del sistema de distribución.Universidad Politécnica Salesiana. Carrera de Ingeniería Eléctrica. Sede QuitoValenzuela Santillán, Alex David2018-01-18T16:41:07Z2018-01-18T16:41:07Z2018-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfBurbano Vásquez, B. A. (2018). Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución. Universidad Politécnica Salesiana. Carrera de Ingeniería Eléctrica. Sede QuitoUPS-KT01462http://dspace.ups.edu.ec/handle/123456789/14997spaAtribución-NoComercial-SinDerivadas 3.0 Ecuadorhttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Politécnica Salesianainstname:Universidad Politécnica Salesianainstacron:UPS2019-01-01T18:52:55Zoai:dspace.ups.edu.ec:123456789/14997Institucionalhttps://dspace.ups.edu.ec/Institución privadahttps://www.ups.edu.ec/https://dspace.ups.edu.ec/oai.Ecuador...opendoar:17372019-01-01T18:52:55Repositorio Universidad Politécnica Salesiana - Universidad Politécnica Salesianafalse |
| spellingShingle | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución Burbano Vásquez, Byron Andrés INGENIERÍA ELÉCTRICA DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA ENERGÍA ELÉCTRICA SISTEMAS DE ENERGÍA ELÉCTRICA CORTOCIRCUITOS |
| status_str | publishedVersion |
| title | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| title_full | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| title_fullStr | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| title_full_unstemmed | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| title_short | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| title_sort | Óptimo despliegue de generación distribuida en base a análisis de fallas en sistemas de distribución |
| topic | INGENIERÍA ELÉCTRICA DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA ENERGÍA ELÉCTRICA SISTEMAS DE ENERGÍA ELÉCTRICA CORTOCIRCUITOS |
| url | http://dspace.ups.edu.ec/handle/123456789/14997 |