Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.

The present researching work was based on the energy consumption study in the perimeter illumination circuit in the Villano A station of the Agip Oil Ecuador oil field through the use of efficient equipment and measuring instruments to determine the energy consumed by sodium vapor lamps of 400 watts...

Полное описание

Сохранить в:
Библиографические подробности
Главный автор: Tapia Tapia, Fredy Norverto (author)
Формат: masterThesis
Язык:spa
Опубликовано: 2015
Предметы:
Online-ссылка:http://repositorio.utc.edu.ec/handle/27000/6158
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!
_version_ 1822282031707455488
author Tapia Tapia, Fredy Norverto
author_facet Tapia Tapia, Fredy Norverto
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Rodríguez, Gustavo
dc.creator.none.fl_str_mv Tapia Tapia, Fredy Norverto
dc.date.none.fl_str_mv 2015-07
2020-08-25T19:27:52Z
2020-08-25T19:27:52Z
dc.format.none.fl_str_mv 161 páginas
dc.identifier.none.fl_str_mv Tapia Tapia F.N. (2015) Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente. U.T.C. Latacunga. 161 p.
MUTC-000313
http://repositorio.utc.edu.ec/handle/27000/6158
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Dirección de Posgrados.
dc.rights.none.fl_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv Gestión de energías
Consumo de energía
Iluminación LED
Ahorro de energía
dc.title.none.fl_str_mv Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description The present researching work was based on the energy consumption study in the perimeter illumination circuit in the Villano A station of the Agip Oil Ecuador oil field through the use of efficient equipment and measuring instruments to determine the energy consumed by sodium vapor lamps of 400 watts that are currently installed. It was important to analyze and evaluate the high consumption of energy to determine and demonstrate that using another lamp it is possible to save it. In this analysis, it was followed the international standards and the electrical codes regulated in the country. The proposal is to use another type of lighting as the LED. This lamp type was evaluated at the same time that its technical features and benefits. The obtained results allowed proposing a change of selected lamps, which are the FMV 25L LED. This type of lights has technical guarantee and it is long lasting. Additionally, The LED could save the energy the 35,35% compared with the lamp that is installed on the electricity pylons of the Villano A station. In respect of the economic factor, it was verified a considerable saving which determines that this study is feasible. It also contributes to prevent the gas emission to the environment which will reduce the environmental pollution due to the energy generation is produced in the oil production factory by the generating sets.
eu_rights_str_mv openAccess
format masterThesis
id UTC_009ccf1700cb144881191bf6bbdb497b
identifier_str_mv Tapia Tapia F.N. (2015) Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente. U.T.C. Latacunga. 161 p.
MUTC-000313
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/6158
publishDate 2015
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Dirección de Posgrados.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.Tapia Tapia, Fredy NorvertoGestión de energíasConsumo de energíaIluminación LEDAhorro de energíaThe present researching work was based on the energy consumption study in the perimeter illumination circuit in the Villano A station of the Agip Oil Ecuador oil field through the use of efficient equipment and measuring instruments to determine the energy consumed by sodium vapor lamps of 400 watts that are currently installed. It was important to analyze and evaluate the high consumption of energy to determine and demonstrate that using another lamp it is possible to save it. In this analysis, it was followed the international standards and the electrical codes regulated in the country. The proposal is to use another type of lighting as the LED. This lamp type was evaluated at the same time that its technical features and benefits. The obtained results allowed proposing a change of selected lamps, which are the FMV 25L LED. This type of lights has technical guarantee and it is long lasting. Additionally, The LED could save the energy the 35,35% compared with the lamp that is installed on the electricity pylons of the Villano A station. In respect of the economic factor, it was verified a considerable saving which determines that this study is feasible. It also contributes to prevent the gas emission to the environment which will reduce the environmental pollution due to the energy generation is produced in the oil production factory by the generating sets.El trabajo de investigación se realizó en base a un estudio del consumo de energía eléctrica en el circuito de iluminación perimetral de la estación Villano A del campo petrolero Agip Oíl Ecuador, utilizando equipos e instrumentos de medición eficientes para determinar la potencia consumida por las lámparas de vapor de sodio de 400 vatios que están instaladas en la actualidad. Al analizar y evaluar los consumos altos de energía eléctrica se decide probar y demostrar que al utilizar otro tipo de lámpara se puede determinar un ahorro de energía eléctrica, para dicho análisis se han seguido las normas internacionales y códigos eléctricos reglamentados en el país. La propuesta es utilizar otro tipo de iluminación como es la Led, se valoró el tipo de lámpara, sus características técnicas y los beneficios que brinda este tipo de iluminación, al analizar los resultados se decide proponer el cambio de lámparas seleccionando la FMV 25L LED. Este tipo de luminarias tiene garantía técnica y una vida útil muy larga, adicional se verifico un ahorro de energía eléctrica del 33,35 % respecto a la lámpara que está instalada en los postes de iluminación de la estación Villano A. Con respecto al tema económico se comprobó un ahorro considerable determinando que el estudio de investigación es factible, por otro lado se evitará la emisión gases al medio ambiente disminuyendo el impacto ambiental ya que la generación eléctrica que se produce en la planta de producción de petróleo es mediante grupos electrógenos.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Dirección de Posgrados.Rodríguez, Gustavo2020-08-25T19:27:52Z2020-08-25T19:27:52Z2015-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis161 páginasTapia Tapia F.N. (2015) Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente. U.T.C. Latacunga. 161 p.MUTC-000313http://repositorio.utc.edu.ec/handle/27000/6158spaclosedAccesshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-08-26T08:00:22Zoai:oai:repositorio.utc.edu.ec:27000:27000/6158Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:25.244877Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
Tapia Tapia, Fredy Norverto
Gestión de energías
Consumo de energía
Iluminación LED
Ahorro de energía
status_str publishedVersion
title Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
title_full Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
title_fullStr Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
title_full_unstemmed Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
title_short Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
title_sort Análisis y evaluación del consumo de energía eléctrica en el sistema de iluminación exterior en la estación Villano del campo petrolero Agip Oíl Ecuador en la provincia de Pastaza en el año 2014. Rediseño del sistema de iluminación exterior para que técnica y energéticamente sea eficiente.
topic Gestión de energías
Consumo de energía
Iluminación LED
Ahorro de energía
url http://repositorio.utc.edu.ec/handle/27000/6158