Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv

Power system equipment when handling high voltage and current levels, are prone to generate electric and magnetic fields (EMF). Transmission lines, being part of the SEP and being at a low frequency (50/60Hz), generate an electric field when the conductor cables are subjected to a certain voltage, a...

Fuld beskrivelse

Saved in:
Bibliografiske detaljer
Hovedforfatter: Velasco Cayo, María Fernanda (author)
Format: bachelorThesis
Sprog:spa
Udgivet: 2021
Fag:
Online adgang:http://repositorio.utc.edu.ec/handle/27000/7854
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
_version_ 1822282043486109696
author Velasco Cayo, María Fernanda
author_facet Velasco Cayo, María Fernanda
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Proaño, Xavier
dc.creator.none.fl_str_mv Velasco Cayo, María Fernanda
dc.date.none.fl_str_mv 2021-12-15T14:43:35Z
2021-12-15T14:43:35Z
2021-03
dc.format.none.fl_str_mv 85 páginas
dc.identifier.none.fl_str_mv Velasco Cayo María Fernanda (2021); Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv. UTC. Latacunga. 85 p.
PI-001673
http://repositorio.utc.edu.ec/handle/27000/7854
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv CAMPO ELÉCTRICO
CAMPO MAGNÉTICO
LÍNEAS DE TRANSMISIÓN
FRANJA DE SERVIDUMBRE
ELÉCTRICA
dc.title.none.fl_str_mv Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description Power system equipment when handling high voltage and current levels, are prone to generate electric and magnetic fields (EMF). Transmission lines, being part of the SEP and being at a low frequency (50/60Hz), generate an electric field when the conductor cables are subjected to a certain voltage, and a magnetic field when an electric current flow through them; these emission levels must be below the limits established by national and international regulations. The objective of this project is to estimate the EMF of the section belonging to the Cotopaxi Province of the Santa Rosa-Totoras 230 kV Line, for which, first, the state of the artworks associated with the study of the electric field, magnetic field, and EMF in electric power systems was reviewed. Then, the route of the transmission line was designed by means of the PLS_CADD software, and by means of the EMF calculation module of this program, the values of electric and magnetic fields of the transmission line were obtained. In addition, applying the calculation methodology used by the Electric Power Research Institute (EPRI), the levels of electric and magnetic fields emitted by the line under study were determined. Finally, with these results, a statistical analysis is performed to determine if the EMF emissions of the Santa Rosa-Totoras line are within the limits established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), as well as the most representative values of electric and magnetic field present within the easement strip.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_02290ed7707c7dfaf2b60e0c04562b83
identifier_str_mv Velasco Cayo María Fernanda (2021); Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv. UTC. Latacunga. 85 p.
PI-001673
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/7854
publishDate 2021
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kvVelasco Cayo, María FernandaCAMPO ELÉCTRICOCAMPO MAGNÉTICOLÍNEAS DE TRANSMISIÓNFRANJA DE SERVIDUMBREELÉCTRICAPower system equipment when handling high voltage and current levels, are prone to generate electric and magnetic fields (EMF). Transmission lines, being part of the SEP and being at a low frequency (50/60Hz), generate an electric field when the conductor cables are subjected to a certain voltage, and a magnetic field when an electric current flow through them; these emission levels must be below the limits established by national and international regulations. The objective of this project is to estimate the EMF of the section belonging to the Cotopaxi Province of the Santa Rosa-Totoras 230 kV Line, for which, first, the state of the artworks associated with the study of the electric field, magnetic field, and EMF in electric power systems was reviewed. Then, the route of the transmission line was designed by means of the PLS_CADD software, and by means of the EMF calculation module of this program, the values of electric and magnetic fields of the transmission line were obtained. In addition, applying the calculation methodology used by the Electric Power Research Institute (EPRI), the levels of electric and magnetic fields emitted by the line under study were determined. Finally, with these results, a statistical analysis is performed to determine if the EMF emissions of the Santa Rosa-Totoras line are within the limits established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), as well as the most representative values of electric and magnetic field present within the easement strip.Los equipos de un sistema de potencia al manejar altos niveles de voltaje y corriente, son propensos a generar campos eléctricos y magnéticos (CEM). Las líneas de transmisión al ser parte del SEP y estar a una baja frecuencia (50/60Hz) generan un campo eléctrico cuando los cables conductores son sometidos a una determinada tensión, y un campo magnético cuando fluye por ellos una corriente eléctrica, estos niveles de emisión deben estar por debajo de los límites establecidos por las normativas nacionales e internacionales. El objetivo del presente proyecto es estimar los CEM del tramo perteneciente a la Provincia de Cotopaxi de la Línea Santa Rosa-Totoras 230 kV, para lo que, en principio se revisó el estado del arte de trabajos asociados al estudio de campo eléctrico, campo magnético, y los CEM en los sistemas eléctricos de potencia. A continuación, se diseñó la ruta de la línea de transmisión por medio del software PLS_CADD y mediante el módulo de cálculo de CEM de este programa, se obtienen los valores de campos eléctricos y magnéticos de la línea de transmisión, Además, aplicando la metodología de cálculo utilizado por Electric Power Research Institute (EPRI) se determinaron los niveles de campo eléctrico y magnético emitidos por la línea en estudio. Finalmente, con estos resultados se realiza un análisis estadístico para determinar si las emisiones de CEM de la línea Santa Rosa-Totoras se encuentran dentro de los límites establecidos por la Comisión Internacional de Protección de radiaciones No Ionizantes (ICNIRP), así como los valores más representativos de campo eléctrico y magnético presentes dentro de la franja de servidumbre.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)Proaño, Xavier2021-12-15T14:43:35Z2021-12-15T14:43:35Z2021-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis85 páginasVelasco Cayo María Fernanda (2021); Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv. UTC. Latacunga. 85 p.PI-001673http://repositorio.utc.edu.ec/handle/27000/7854spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2021-12-16T08:00:43Zoai:oai:repositorio.utc.edu.ec:27000:27000/7854Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:57.044906Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
Velasco Cayo, María Fernanda
CAMPO ELÉCTRICO
CAMPO MAGNÉTICO
LÍNEAS DE TRANSMISIÓN
FRANJA DE SERVIDUMBRE
ELÉCTRICA
status_str publishedVersion
title Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
title_full Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
title_fullStr Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
title_full_unstemmed Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
title_short Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
title_sort Estimación de los campos electromagnéticos del tramo perteneciente a la provincia de Cotopaxi de la línea santa Rosa-Totoras 230 kv
topic CAMPO ELÉCTRICO
CAMPO MAGNÉTICO
LÍNEAS DE TRANSMISIÓN
FRANJA DE SERVIDUMBRE
ELÉCTRICA
url http://repositorio.utc.edu.ec/handle/27000/7854