Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.

The problem is focused on the field of thermal efficiency for power generation and distribution of steam. Itis justified from current government policies related to the new energy matrix and its focus on efficiency. The hypothesis proposes: The reduction of heat losses in the distribution system and...

Full description

Saved in:
Bibliographic Details
Main Author: Cabrera Anda, Santiago Paúl (author)
Format: masterThesis
Language:spa
Published: 2016
Subjects:
Online Access:http://repositorio.utc.edu.ec/handle/27000/6070
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1822282031139127296
author Cabrera Anda, Santiago Paúl
author_facet Cabrera Anda, Santiago Paúl
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Torres, Enrique
dc.creator.none.fl_str_mv Cabrera Anda, Santiago Paúl
dc.date.none.fl_str_mv 2016-06
2020-08-20T18:24:29Z
2020-08-20T18:24:29Z
dc.format.none.fl_str_mv 99 páginas
dc.identifier.none.fl_str_mv Cabrera Anda. S.P. (2016) Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético. U.T.C. Latacunga. 99 p.
MUTC-000439
http://repositorio.utc.edu.ec/handle/27000/6070
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Dirección de Posgrados.
dc.rights.none.fl_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv Gestión de energías
Pérdidas Térmicas
Aprovechamiento de energía
Generación y distribución de vapor
dc.title.none.fl_str_mv Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description The problem is focused on the field of thermal efficiency for power generation and distribution of steam. Itis justified from current government policies related to the new energy matrix and its focus on efficiency. The hypothesis proposes: The reduction of heat losses in the distribution system and steam generation allow to obtain energy savings and increase energy efficiency, which will optimize the degree of energy efficiency at the Power Machines Area belonging to "Dr. Julio Enrique Paredes" SOLCA Tungurahua Oncology Unit Hospital. The theoretical framework exposes concepts related to Evaluation of thermal losses and energy balance. The methodology applied techniques such as observation and measurement using digital tools such as thermal camera and psychrometer for obtaining data. The proposal suggests using 6,9 kW of 88,6 kW waste heat in the exhaust gases from the chimney by heat exchange to obtain 108 kg/h of additional hot water for sanitary use, representing an increase of 1,2 % in the overall efficiency of the steam generation process.
eu_rights_str_mv openAccess
format masterThesis
id UTC_164cc4dee6f79367c6fed610d16d44ab
identifier_str_mv Cabrera Anda. S.P. (2016) Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético. U.T.C. Latacunga. 99 p.
MUTC-000439
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/6070
publishDate 2016
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Dirección de Posgrados.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.Cabrera Anda, Santiago PaúlGestión de energíasPérdidas TérmicasAprovechamiento de energíaGeneración y distribución de vaporThe problem is focused on the field of thermal efficiency for power generation and distribution of steam. Itis justified from current government policies related to the new energy matrix and its focus on efficiency. The hypothesis proposes: The reduction of heat losses in the distribution system and steam generation allow to obtain energy savings and increase energy efficiency, which will optimize the degree of energy efficiency at the Power Machines Area belonging to "Dr. Julio Enrique Paredes" SOLCA Tungurahua Oncology Unit Hospital. The theoretical framework exposes concepts related to Evaluation of thermal losses and energy balance. The methodology applied techniques such as observation and measurement using digital tools such as thermal camera and psychrometer for obtaining data. The proposal suggests using 6,9 kW of 88,6 kW waste heat in the exhaust gases from the chimney by heat exchange to obtain 108 kg/h of additional hot water for sanitary use, representing an increase of 1,2 % in the overall efficiency of the steam generation process.El problema se enfoca en el ámbito de la eficiencia térmica para sistemas de generación y distribución de vapor. Se justifica a partir de las actuales políticas gubernamentales relacionadas con la nueva Matriz energética y su enfoque hacia la eficiencia. La hipótesis plantea que: La reducción de pérdidas térmicas en el sistema de generación y distribución de vapor permitirá obtener un ahorro energético e incrementar la eficiencia energética, lo cual optimizará el grado de aprovechamiento energético en la Casa de Máquinas del Hospital “Dr. Julio Enrique Paredes” Unidad Oncológica SOLCA Tungurahua. El marco teórico expone conceptos relacionados con: evaluación de pérdidas térmicas y balance energético. La metodología aplica técnicas como la observación y medición usando instrumentos digitales como: cámara termográfica y psicrómetro para obtención de datos. La propuesta sugiere aprovechar 6,9 kW de los 88,6 kW de calor residual en los gases de escape de la chimenea para mediante intercambio de calor obtener 108 kg/h adicionales de agua caliente para uso sanitario, que representa un incremento de 1,2 % en la eficiencia global del proceso de generación de vapor.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: Dirección de Posgrados.Torres, Enrique2020-08-20T18:24:29Z2020-08-20T18:24:29Z2016-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis99 páginasCabrera Anda. S.P. (2016) Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético. U.T.C. Latacunga. 99 p.MUTC-000439http://repositorio.utc.edu.ec/handle/27000/6070spaclosedAccesshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-08-21T08:00:30Zoai:oai:repositorio.utc.edu.ec:27000:27000/6070Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:23.566979Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
Cabrera Anda, Santiago Paúl
Gestión de energías
Pérdidas Térmicas
Aprovechamiento de energía
Generación y distribución de vapor
status_str publishedVersion
title Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
title_full Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
title_fullStr Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
title_full_unstemmed Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
title_short Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
title_sort Evaluación de pérdidas térmicas en el sistema de generación y distribución de vapor en el hospital "Dr. Julio Enrique Paredes" Unidad Oncológica Solca Tungurahua, año 2014. Propuesta para optimización del aprovechamiento energético.
topic Gestión de energías
Pérdidas Térmicas
Aprovechamiento de energía
Generación y distribución de vapor
url http://repositorio.utc.edu.ec/handle/27000/6070