Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.

This research study shows the problem caused by the incidence of the electrical behavior of the distribution transformers in the electrical service reliability of ‘Tambo’ feeder in Pelileo substation of ‘Empresa Electrica Ambato S.A. (EEASA)’, during the year 2016. It was established through CONELEC...

Volledige beschrijving

Bewaard in:
Bibliografische gegevens
Hoofdauteur: Gómez Cevallos, Juan Carlos (author)
Formaat: masterThesis
Taal:spa
Gepubliceerd in: 2017
Onderwerpen:
Online toegang:http://repositorio.utc.edu.ec/handle/27000/6387
Tags: Voeg label toe
Geen labels, Wees de eerste die dit record labelt!
_version_ 1862869130795810816
author Gómez Cevallos, Juan Carlos
author_facet Gómez Cevallos, Juan Carlos
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Freire Martínez, Luigi Orlando, Msc.
dc.creator.none.fl_str_mv Gómez Cevallos, Juan Carlos
dc.date.none.fl_str_mv 2017-11
2020-09-04T19:32:47Z
2020-09-04T19:32:47Z
dc.format.none.fl_str_mv 110 páginas
application/pdf
dc.identifier.none.fl_str_mv Gómez Cevallos, Juan Carlos (2017); Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias. UTC. Latacunga. 110 p.
MUTC-000607
http://repositorio.utc.edu.ec/handle/27000/6387
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
dc.rights.none.fl_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv RED ELÉCTRICA
SISTEMA RADIAL
RED DE DISTRIBUCIÓN
GESTIÓN ENERGÉTICA
dc.title.none.fl_str_mv Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description This research study shows the problem caused by the incidence of the electrical behavior of the distribution transformers in the electrical service reliability of ‘Tambo’ feeder in Pelileo substation of ‘Empresa Electrica Ambato S.A. (EEASA)’, during the year 2016. It was established through CONELEC 004/01 current regulation in the country, as well as works, papers and scientific journals related to the quality of technical service an adequate evaluation of the electrical system of the feeder. Through the field research and the help of measurement equipment such as energy analyzers, clamp current sensor, Siscp and Dataview software, was possible to obtain the information of electrical variables such as apparent power, grounding resistance, voltage, flicker, harmonic distortion in voltage, power factor establishing direct contact with reality without a manipulation of data. The methodology was both deductive and inductive. The first method was used from general principles for the measurement of parameters and the second one from the particular study of the electrical variables in order to determine in general the behavior of the feeder. In addition, an economic evaluation regarding the cost of the project implementation was made. Finally, the results were established through a Pareto chart and they determined that primary Tambo has the most critical variables to be solved with 59 load centers. It means that a 17% requires an urgent replacement, 259 grounded that represents a 76% do not comply with the regulations and 20 transformers identified with low power factor. Furthermore, regarding the economic analysis, for the implementation of the proposal requires an investment of 152 159, 13 dollars.
eu_rights_str_mv openAccess
format masterThesis
id UTC_1b791eadd2d9d4a4a480fbd81de2612e
identifier_str_mv Gómez Cevallos, Juan Carlos (2017); Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias. UTC. Latacunga. 110 p.
MUTC-000607
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:repositorio.utc.edu.ec:27000/6387
publishDate 2017
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv closedAccess
http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.Gómez Cevallos, Juan CarlosRED ELÉCTRICASISTEMA RADIALRED DE DISTRIBUCIÓNGESTIÓN ENERGÉTICAThis research study shows the problem caused by the incidence of the electrical behavior of the distribution transformers in the electrical service reliability of ‘Tambo’ feeder in Pelileo substation of ‘Empresa Electrica Ambato S.A. (EEASA)’, during the year 2016. It was established through CONELEC 004/01 current regulation in the country, as well as works, papers and scientific journals related to the quality of technical service an adequate evaluation of the electrical system of the feeder. Through the field research and the help of measurement equipment such as energy analyzers, clamp current sensor, Siscp and Dataview software, was possible to obtain the information of electrical variables such as apparent power, grounding resistance, voltage, flicker, harmonic distortion in voltage, power factor establishing direct contact with reality without a manipulation of data. The methodology was both deductive and inductive. The first method was used from general principles for the measurement of parameters and the second one from the particular study of the electrical variables in order to determine in general the behavior of the feeder. In addition, an economic evaluation regarding the cost of the project implementation was made. Finally, the results were established through a Pareto chart and they determined that primary Tambo has the most critical variables to be solved with 59 load centers. It means that a 17% requires an urgent replacement, 259 grounded that represents a 76% do not comply with the regulations and 20 transformers identified with low power factor. Furthermore, regarding the economic analysis, for the implementation of the proposal requires an investment of 152 159, 13 dollars.Esta investigación trata acerca de la problemática ocasionada por la incidencia del comportamiento eléctrico de los transformadores de distribución en la confiabilidad de servicio eléctrico del alimentador Tambo de la subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016, estableciendo mediante la regulación CONELEC 004/01 vigente en el país así como también trabajos, artículos y revistas científicas referidas a la calidad de servicio técnico una adecuada evaluación del sistema eléctrico del alimentador en estudio. Mediante la investigación de campo y con la ayuda de equipos de medida como analizadores de energía, telurómetro de pinzas y software Siscp y Dataview se levantó la información de variables eléctricas como la potencia aparente, resistencia de puesta a tierra, voltaje, flicker, distorsión armónica en voltaje, factor de potencia estableciendo contacto directo con la realidad sin que exista manipulación de los datos. Los métodos usados fueron el deductivo e inductivo el primero utilizado a partir de principios generales para la medición de los parámetro a ser medidos y el segundo empezando desde el estudio particular de las variables eléctricas hasta determinar en forma general el comportamiento del alimentador en estudio, adicionalmente se realizó una valoración económica del costo de implementación de la propuesta del proyecto. Finalmente de los resultados obtenidos se estableció mediante un diagrama de Pareto que de los parámetros en estudio los niveles de carga de los transformadores de distribución, las puestas a tierra y el factor de potencia del primario.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).Freire Martínez, Luigi Orlando, Msc.2020-09-04T19:32:47Z2020-09-04T19:32:47Z2017-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis110 páginasapplication/pdfGómez Cevallos, Juan Carlos (2017); Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias. UTC. Latacunga. 110 p.MUTC-000607http://repositorio.utc.edu.ec/handle/27000/6387spaclosedAccesshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-09-05T08:00:35Zoai:repositorio.utc.edu.ec:27000/6387Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-04-19T03:38:19.793825Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
Gómez Cevallos, Juan Carlos
RED ELÉCTRICA
SISTEMA RADIAL
RED DE DISTRIBUCIÓN
GESTIÓN ENERGÉTICA
status_str publishedVersion
title Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
title_full Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
title_fullStr Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
title_full_unstemmed Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
title_short Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
title_sort Diagnóstico de la confiabilidad de servicio y su relación con el comportamiento eléctrico de los transformadores de distribución del alimentador Tambo, subestación Pelileo de la Empresa Eléctrica Ambato S.A. (EEASA), durante el año 2016. Propuesta de repotenciación de centros de transformación, redes primarias y secundarias.
topic RED ELÉCTRICA
SISTEMA RADIAL
RED DE DISTRIBUCIÓN
GESTIÓN ENERGÉTICA
url http://repositorio.utc.edu.ec/handle/27000/6387