Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.

The proposed research is part of renewable energies, in the development and impact that is taking place on a day-to-day basis, being a technology in constant development, for which the design of a conventional flat collector is varied, creating a double chamber of circulation of air by implementing...

Fuld beskrivelse

Saved in:
Bibliografiske detaljer
Hovedforfatter: Sailema Moreta, Carlos Patricio (author)
Format: masterThesis
Sprog:spa
Udgivet: 2021
Fag:
Online adgang:http://repositorio.utc.edu.ec/handle/27000/8379
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
_version_ 1858430327399120896
author Sailema Moreta, Carlos Patricio
author_facet Sailema Moreta, Carlos Patricio
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Gallardo, Cristian
dc.creator.none.fl_str_mv Sailema Moreta, Carlos Patricio
dc.date.none.fl_str_mv 2021-11
2022-04-08T20:12:06Z
2022-04-08T20:12:06Z
dc.format.none.fl_str_mv 67 páginas
application/pdf
dc.identifier.none.fl_str_mv Sailema Moreta Carlos Patricio (2021), Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional. UTC. Latacunga. 67 p.
MUTC-001107
http://repositorio.utc.edu.ec/handle/27000/8379
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv CAPTADOR
PLACA INTERMEDIA
TEMPERATURA
IRRADIACIÓN
ELECTROMECÁNICA
dc.title.none.fl_str_mv Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description The proposed research is part of renewable energies, in the development and impact that is taking place on a day-to-day basis, being a technology in constant development, for which the design of a conventional flat collector is varied, creating a double chamber of circulation of air by implementing an additional internal intermediate plate, the system is located in Ecuador, Cotopaxi, Latacunga where the solar radiation indexes are among the highest registered globally. The circulation area is 100cm x 50cm and 10cm, the measurements are made under different environmental parameters, whether high or low looking for a behavior standard, in a measured time of 5 hsp, and with flows given by a blower doing the forced ventilation system, monitoring was given at 20%, 30%, 40% and 50%, which are reflected in the output speed of 2.2m/s, 6.1m/s, 9.1m/s and 11.5m/s respectively. The temperature census variables are arranged at 5 points along the collector to obtain environmental data, air inlet, plate and glass, intermediate points of the collector and the plate, point prior to the air outlet, plate and glass and finally the air outlet, all the data stored locally in an open loop system, on the other hand a meteorological station was located that also obtains the data locally, providing the measurements of irradiation and wind speed, the values to match are 60 data per hour for the analysis and the average performance of 66.03% vs 58.7% for the first case, 69.48% vs 64.58% for the second case, 63.88% vs 53.03% for the third case and 69.33% vs 65.28% for the last case measured with the bias in favor of the proposal in relation to the measured reference.
eu_rights_str_mv openAccess
format masterThesis
id UTC_32d2b21d9a33e7b3ddf39a8a2feb4f1c
identifier_str_mv Sailema Moreta Carlos Patricio (2021), Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional. UTC. Latacunga. 67 p.
MUTC-001107
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:repositorio.utc.edu.ec:27000/8379
publishDate 2021
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.Sailema Moreta, Carlos PatricioCAPTADORPLACA INTERMEDIATEMPERATURAIRRADIACIÓNELECTROMECÁNICAThe proposed research is part of renewable energies, in the development and impact that is taking place on a day-to-day basis, being a technology in constant development, for which the design of a conventional flat collector is varied, creating a double chamber of circulation of air by implementing an additional internal intermediate plate, the system is located in Ecuador, Cotopaxi, Latacunga where the solar radiation indexes are among the highest registered globally. The circulation area is 100cm x 50cm and 10cm, the measurements are made under different environmental parameters, whether high or low looking for a behavior standard, in a measured time of 5 hsp, and with flows given by a blower doing the forced ventilation system, monitoring was given at 20%, 30%, 40% and 50%, which are reflected in the output speed of 2.2m/s, 6.1m/s, 9.1m/s and 11.5m/s respectively. The temperature census variables are arranged at 5 points along the collector to obtain environmental data, air inlet, plate and glass, intermediate points of the collector and the plate, point prior to the air outlet, plate and glass and finally the air outlet, all the data stored locally in an open loop system, on the other hand a meteorological station was located that also obtains the data locally, providing the measurements of irradiation and wind speed, the values to match are 60 data per hour for the analysis and the average performance of 66.03% vs 58.7% for the first case, 69.48% vs 64.58% for the second case, 63.88% vs 53.03% for the third case and 69.33% vs 65.28% for the last case measured with the bias in favor of the proposal in relation to the measured reference.La investigación propuesta se enmarca en las energías renovables, en el desarrollo e impacto que se va dando en el día a día siendo una tecnología en constante desarrollo, por lo cual se varía el diseño de un captador plano convencional creando una doble cámara de circulación de aire al implementar una placa interna intermedia adicional, el sistema está ubicado en Ecuador, Cotopaxi, Latacunga donde los índices de radiación solar son de los más altos registrados a nivel global. El área de circulación es de 100cm x 50cm y 10cm, las mediciones se las realiza bajo distintos parámetros ambientales, ya sean altos y bajos buscando un estándar de comportamiento, en un tiempo medido de 5 hsp, y con caudales dados por un soplador haciendo el sistema de ventilación forzada, el monitoreo se dio al 20%, 30%, 40% y 50% los mismos que son reflejados en la velocidad de salida de 2.2m/s, 6.1m/s, 9.1m/s y 11.5m/s respectivamente. Las variables censadas de temperatura se encuentran dispuestas en 5 puntos a los largo del captador para obtener los datos ambientales, de entrada del aire, placa y vidrio, puntos intermedios del captador y la placa, punto previo a la salida de aire, placa y vidrio y finalmente la salida de aire, todos los datos almacenados de manera local en un sistema de lazo abierto, por otra parte se ubicó una estación meteorológica que también obtiene los datos de forma local brindando las medidas de irradiación y velocidad del viento, los valores a coincidir son de 60 datos por hora para el análisis y el rendimiento promedio de 66.03% vs 58.7% para el primer caso, 69.48% vs 64.58% para el segundo caso, 63.88% vs 53.03% para el tercer caso y 69.33% vs 65.28% para el último caso medido con la inclinación a favor de la propuesta en relación a la referencia medida.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.Gallardo, Cristian2022-04-08T20:12:06Z2022-04-08T20:12:06Z2021-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis67 páginasapplication/pdfSailema Moreta Carlos Patricio (2021), Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional. UTC. Latacunga. 67 p.MUTC-001107http://repositorio.utc.edu.ec/handle/27000/8379spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2022-04-09T08:01:16Zoai:repositorio.utc.edu.ec:27000/8379Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-03-01T03:44:36.898030Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
Sailema Moreta, Carlos Patricio
CAPTADOR
PLACA INTERMEDIA
TEMPERATURA
IRRADIACIÓN
ELECTROMECÁNICA
status_str publishedVersion
title Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
title_full Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
title_fullStr Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
title_full_unstemmed Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
title_short Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
title_sort Análisis comparativo del rendimiento térmico de un captador solar plano para calentamiento de aire con la aplicación de una placa absorbedora interna adicional.
topic CAPTADOR
PLACA INTERMEDIA
TEMPERATURA
IRRADIACIÓN
ELECTROMECÁNICA
url http://repositorio.utc.edu.ec/handle/27000/8379