Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito
Currently, final consumers impose greater requirements on the quality of service, especially in services provided by electricity distributors, this means that technology, more efficient equipment or elements that improve electricity service must be used. More and more protection and switching equipm...
Gespeichert in:
| 1. Verfasser: | |
|---|---|
| Format: | masterThesis |
| Sprache: | spa |
| Veröffentlicht: |
2023
|
| Schlagworte: | |
| Online Zugang: | http://repositorio.utc.edu.ec/handle/27000/10769 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1822282061107429376 |
|---|---|
| author | Sisa Sisa, Victor |
| author_facet | Sisa Sisa, Victor |
| author_role | author |
| collection | Repositorio Universidad Técnica de Cotopaxi |
| dc.contributor.none.fl_str_mv | Jiménez Jiménez, Diego |
| dc.creator.none.fl_str_mv | Sisa Sisa, Victor |
| dc.date.none.fl_str_mv | 2023-09-18T15:21:43Z 2023-09-18T15:21:43Z 2023 |
| dc.format.none.fl_str_mv | 79 páginas |
| dc.identifier.none.fl_str_mv | Sisa Sisa Victor (2023); Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito. UTC. Latacunga. 79 p. MUTC-001670 http://repositorio.utc.edu.ec/handle/27000/10769 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC) |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Técnica de Cotopaxi instname:Universidad Técnica de Cotopaxi instacron:UTC |
| dc.subject.none.fl_str_mv | DISTRIBUCIÓN CONFIABILIDAD CONTINUIDAD RECONECTADOR ELÉCTRICA |
| dc.title.none.fl_str_mv | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis |
| description | Currently, final consumers impose greater requirements on the quality of service, especially in services provided by electricity distributors, this means that technology, more efficient equipment or elements that improve electricity service must be used. More and more protection and switching equipment must be introduced into electrical networks to minimize the number of users without electricity. Fulfilling the objective of guaranteeing the reliability and continuity of the supply of electrical energy to users, this paper analyzes a methodology for the optimal location of recloser equipment in electrical distribution systems. There are several alternative ways to improve the continuity of energy. One of them is the so-called reconnection of electrical service, since it has been observed in several studies that 85 % of the errors in the distribution networks are not permanent, it is that is, after a certain time the error has been omitted, that is, the fault is cleared. For this reason, the problem is minimized with the installation of disconnect/reconnect equipment called reclosers. By quantifying the reliability of electrical distribution systems and their service quality indices, weak points can be determined and, therefore, identify, quantitatively observe the correct recognition place to make the system more reliable and improve these indices. |
| eu_rights_str_mv | openAccess |
| format | masterThesis |
| id | UTC_362f1ba4ce4b09bbbc3bf48e3945da91 |
| identifier_str_mv | Sisa Sisa Victor (2023); Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito. UTC. Latacunga. 79 p. MUTC-001670 |
| instacron_str | UTC |
| institution | UTC |
| instname_str | Universidad Técnica de Cotopaxi |
| language | spa |
| network_acronym_str | UTC |
| network_name_str | Repositorio Universidad Técnica de Cotopaxi |
| oai_identifier_str | oai:oai:repositorio.utc.edu.ec:27000:27000/10769 |
| publishDate | 2023 |
| publisher.none.fl_str_mv | Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC) |
| reponame_str | Repositorio Universidad Técnica de Cotopaxi |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica QuitoSisa Sisa, VictorDISTRIBUCIÓNCONFIABILIDADCONTINUIDADRECONECTADORELÉCTRICACurrently, final consumers impose greater requirements on the quality of service, especially in services provided by electricity distributors, this means that technology, more efficient equipment or elements that improve electricity service must be used. More and more protection and switching equipment must be introduced into electrical networks to minimize the number of users without electricity. Fulfilling the objective of guaranteeing the reliability and continuity of the supply of electrical energy to users, this paper analyzes a methodology for the optimal location of recloser equipment in electrical distribution systems. There are several alternative ways to improve the continuity of energy. One of them is the so-called reconnection of electrical service, since it has been observed in several studies that 85 % of the errors in the distribution networks are not permanent, it is that is, after a certain time the error has been omitted, that is, the fault is cleared. For this reason, the problem is minimized with the installation of disconnect/reconnect equipment called reclosers. By quantifying the reliability of electrical distribution systems and their service quality indices, weak points can be determined and, therefore, identify, quantitatively observe the correct recognition place to make the system more reliable and improve these indices.Actualmente, los consumidores finales imponen mayores requisitos a la calidad del servicio, especialmente en los servicios proporcionados por los distribuidores de energía eléctrica, esto conlleva que se deba recurrir a la tecnología, equipos eficientes o los elementos que el servicio eléctrico. Se debe introducir cada vez equipos de protección y maniobra en las redes eléctricas para minimizar la cantidad de usuarios sin electricidad. Cumpliendo el objetivo de garantizar la confiabilidad y continuidad del suministro de energía eléctrica hacia los usuarios, en el presente trabajo se analiza una metodología para la ubicación óptima de equipos reconectadores en los sistemas eléctricos de distribución. Hay varias formas alternativas de mejorar la continuidad de la energía, una de ella, es la denominada reconexión de servicio eléctrico, ya que se ha observado en varios estudios que el 85 % de los errores de las redes de distribución no son permanente, es decir, después de un tiempo determinando se ha omitido el error, es decir, se despeja la falla. Por esta razón, el problema se reduce al mínimo con la instalación de equipos de desconexión/reconexión denominados reconectadores. Al cuantificar la confiabilidad de los sistemas eléctricos de distribución y sus índices de calidad de servicio, se pueden determinar los puntos débiles y, por lo tanto, identificar, observar cuantitativamente el lugar de reconocimiento para que sea confiable el sistema y mejorar estos índices.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)Jiménez Jiménez, Diego2023-09-18T15:21:43Z2023-09-18T15:21:43Z2023info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis79 páginasSisa Sisa Victor (2023); Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito. UTC. Latacunga. 79 p.MUTC-001670http://repositorio.utc.edu.ec/handle/27000/10769spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-09-19T08:00:19Zoai:oai:repositorio.utc.edu.ec:27000:27000/10769Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:45:51.905959Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue |
| spellingShingle | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito Sisa Sisa, Victor DISTRIBUCIÓN CONFIABILIDAD CONTINUIDAD RECONECTADOR ELÉCTRICA |
| status_str | publishedVersion |
| title | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| title_full | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| title_fullStr | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| title_full_unstemmed | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| title_short | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| title_sort | Ubicación óptima de reconectadores en el alimentador primario “G” de la subestación Cristianía perteneciente a la Empresa Eléctrica Quito |
| topic | DISTRIBUCIÓN CONFIABILIDAD CONTINUIDAD RECONECTADOR ELÉCTRICA |
| url | http://repositorio.utc.edu.ec/handle/27000/10769 |