Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador.
Hospital wastewater contains pathogenic microorganisms and substances of variable toxicity such as drugs, personal hygiene products and disinfectants, so its discharge without proper treatment constitutes an important environmental problem. The dialysis unit of Hospital Quito N ° 1 provides its serv...
Zapisane w:
| 1. autor: | |
|---|---|
| Kolejni autorzy: | |
| Format: | bachelorThesis |
| Język: | spa |
| Wydane: |
2021
|
| Hasła przedmiotowe: | |
| Dostęp online: | http://repositorio.utc.edu.ec/handle/27000/11038 |
| Etykiety: |
Dodaj etykietę
Nie ma etykietki, Dołącz pierwszą etykiete!
|
| _version_ | 1858430368528465920 |
|---|---|
| author | Pilco Cedeño, Andrea Mishell |
| author2 | Rodríguez Pallo, Johan Alexander |
| author2_role | author |
| author_facet | Pilco Cedeño, Andrea Mishell Rodríguez Pallo, Johan Alexander |
| author_role | author |
| collection | Repositorio Universidad Técnica de Cotopaxi |
| dc.contributor.none.fl_str_mv | José Luis, Agreda Oña |
| dc.creator.none.fl_str_mv | Pilco Cedeño, Andrea Mishell Rodríguez Pallo, Johan Alexander |
| dc.date.none.fl_str_mv | 2021-03 2023-09-26T15:25:06Z 2023-09-26T15:25:06Z |
| dc.format.none.fl_str_mv | 114 páginas application/pdf |
| dc.identifier.none.fl_str_mv | Pilco Cedeño Andrea Mishell , Rodríguez Pallo Johan Alexander (2021); Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. UTC. Latacunga. 114 p. PC-002885 http://repositorio.utc.edu.ec/handle/27000/11038 |
| dc.language.none.fl_str_mv | spa |
| dc.publisher.none.fl_str_mv | Ecuador. Latacunga. Universidad Técnica de Cotopaxi, (UTC) |
| dc.rights.none.fl_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:Repositorio Universidad Técnica de Cotopaxi instname:Universidad Técnica de Cotopaxi instacron:UTC |
| dc.subject.none.fl_str_mv | UNIDAD DE DIÁLISIS LÍMITES MÁXIMOS PERMISIBLES LÍNEA DE TRATAMIENTO MEDIO AMBIENTE |
| dc.title.none.fl_str_mv | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis |
| description | Hospital wastewater contains pathogenic microorganisms and substances of variable toxicity such as drugs, personal hygiene products and disinfectants, so its discharge without proper treatment constitutes an important environmental problem. The dialysis unit of Hospital Quito N ° 1 provides its service to people who suffer from chronic renal failure in Ecuador, whose treatment must be carried out three times a week, with the help of a dialyzer filter, which performs the purifying and normalizing function of the fluid and blood composition. Disinfection of these equipment as well as instruments carries toxins from the patients. This waste liquid is dumped directly into the sewer system, causing progressive contamination of the water. The investigation proposed a treatment of wastewater generated in the dialysis unit of Hospital Quito N ° 1 - National Police of Ecuador, for which an analysis of laboratory data provided by the same institution was carried out. Through the qualitative multimethodic approach, where it was possible to evaluate the results of physical, chemical and microbiological parameters of the years 2017, 2018 and 2019 from the wastewater of this unit. Where the parameters BOD (421 mg / l - 01/30/2017), COD (1002 mg / l - 01/30/2017) and SAAM (6,852 mg / l-06/10/2019) are not within the Maximum permissible discharge limits to the sewerage system of the Metropolitan District of Quito. Through the relationship between BOD5 and COD whose value is less than 2, it was directed towards a biological treatment line for the management proposal where this project gave a proposal for a wastewater treatment of the unit, giving as a treatment line to a grease trap system, a biodigester and the disinfection of the effluent before its drainage to the sanitary sewer. The main objective of these treatments is to reduce or completely eliminate the pollutant load of the liquid discharge, transforming it into a final effluent that complies with the corresponding environmental regulations and it would be harmless to the environment or il would have a less impact of contamination. |
| eu_rights_str_mv | openAccess |
| format | bachelorThesis |
| id | UTC_4ed4e3350798e4aa89e2be300e261baa |
| identifier_str_mv | Pilco Cedeño Andrea Mishell , Rodríguez Pallo Johan Alexander (2021); Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. UTC. Latacunga. 114 p. PC-002885 |
| instacron_str | UTC |
| institution | UTC |
| instname_str | Universidad Técnica de Cotopaxi |
| language | spa |
| network_acronym_str | UTC |
| network_name_str | Repositorio Universidad Técnica de Cotopaxi |
| oai_identifier_str | oai:repositorio.utc.edu.ec:27000/11038 |
| publishDate | 2021 |
| publisher.none.fl_str_mv | Ecuador. Latacunga. Universidad Técnica de Cotopaxi, (UTC) |
| reponame_str | Repositorio Universidad Técnica de Cotopaxi |
| repository.mail.fl_str_mv | . |
| repository.name.fl_str_mv | Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi |
| repository_id_str | 0 |
| rights_invalid_str_mv | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ |
| spelling | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador.Pilco Cedeño, Andrea MishellRodríguez Pallo, Johan AlexanderUNIDAD DE DIÁLISISLÍMITES MÁXIMOS PERMISIBLESLÍNEA DE TRATAMIENTOMEDIO AMBIENTEHospital wastewater contains pathogenic microorganisms and substances of variable toxicity such as drugs, personal hygiene products and disinfectants, so its discharge without proper treatment constitutes an important environmental problem. The dialysis unit of Hospital Quito N ° 1 provides its service to people who suffer from chronic renal failure in Ecuador, whose treatment must be carried out three times a week, with the help of a dialyzer filter, which performs the purifying and normalizing function of the fluid and blood composition. Disinfection of these equipment as well as instruments carries toxins from the patients. This waste liquid is dumped directly into the sewer system, causing progressive contamination of the water. The investigation proposed a treatment of wastewater generated in the dialysis unit of Hospital Quito N ° 1 - National Police of Ecuador, for which an analysis of laboratory data provided by the same institution was carried out. Through the qualitative multimethodic approach, where it was possible to evaluate the results of physical, chemical and microbiological parameters of the years 2017, 2018 and 2019 from the wastewater of this unit. Where the parameters BOD (421 mg / l - 01/30/2017), COD (1002 mg / l - 01/30/2017) and SAAM (6,852 mg / l-06/10/2019) are not within the Maximum permissible discharge limits to the sewerage system of the Metropolitan District of Quito. Through the relationship between BOD5 and COD whose value is less than 2, it was directed towards a biological treatment line for the management proposal where this project gave a proposal for a wastewater treatment of the unit, giving as a treatment line to a grease trap system, a biodigester and the disinfection of the effluent before its drainage to the sanitary sewer. The main objective of these treatments is to reduce or completely eliminate the pollutant load of the liquid discharge, transforming it into a final effluent that complies with the corresponding environmental regulations and it would be harmless to the environment or il would have a less impact of contamination.Las aguas residuales hospitalarias contienen microorganismos patógenos y sustancias de diversa toxicidad como fármacos, productos de higiene personal y desinfectantes, por lo que su vertido sin un tratamiento adecuado constituye un importante problema medioambiental. La unidad de diálisis del hospital Quito Nº1, presta su servicio a personas que padecen de insuficiencia renal crónica en Ecuador, cuyo tratamiento debe ser realizado tres veces por semana, con la ayuda de un filtro dializador, el cual realiza la función depurativa y normalizadora del líquido y composición de la sangre. La desinfección de estos equipos, así como instrumentales lleva consigo toxinas provenientes de los pacientes. Este líquido de desecho es vertido directamente hacia al sistema de alcantarillado, lo que provoca una contaminación progresiva en el agua. La investigación propuso un tratamiento de aguas residuales generadas en la unidad de diálisis del Hospital Quito N°1 – Policía Nacional del Ecuador, para ello se realizó un análisis de datos de laboratorio otorgados por la misma institución. Por medio del enfoque multimetódico cualitativo, donde se pudo evaluar los resultados de parámetros físicos químicos y microbiológicos de los años 2017, 2018 y 2019 de las aguas residuales de esta unidad. Donde los parámetros DBO (421 mg/l - 30/01/2017), DQO (1002 mg/l - 30/01/2017) y SAAM (6,852 mg/l -10/06/2019) no se encuentran dentro de los límites máximos permisibles de descarga al sistema de alcantarillado del Distrito Metropolitano de Quito. A través de la relación entre DBO5 y DQO cuyo valor es menor a 2, se direccionó hacia una línea de tratamiento bilógico para la propuesta de manejo donde este proyecto dio una propuesta de un tratamiento de aguas residuales de la unidad, dando como línea de tratamiento a un sistema de trampa de grasas, un biodigestor y la desinfección del efluente antes de su drenaje hacia el alcantarillado sanitario. El objetivo primordial de estos tratamientos es reducir o eliminar por completo la carga contaminante de la descarga líquida, transformándola en un efluente final que cumpla con la normativa ambiental correspondiente y sea inofensivo al ambiente o de un impacto menor.Ecuador. Latacunga. Universidad Técnica de Cotopaxi, (UTC)José Luis, Agreda Oña2023-09-26T15:25:06Z2023-09-26T15:25:06Z2021-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis114 páginasapplication/pdfPilco Cedeño Andrea Mishell , Rodríguez Pallo Johan Alexander (2021); Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. UTC. Latacunga. 114 p.PC-002885http://repositorio.utc.edu.ec/handle/27000/11038spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-09-27T08:00:35Zoai:repositorio.utc.edu.ec:27000/11038Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02026-03-01T03:46:15.701905Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue |
| spellingShingle | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. Pilco Cedeño, Andrea Mishell UNIDAD DE DIÁLISIS LÍMITES MÁXIMOS PERMISIBLES LÍNEA DE TRATAMIENTO MEDIO AMBIENTE |
| status_str | publishedVersion |
| title | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| title_full | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| title_fullStr | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| title_full_unstemmed | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| title_short | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| title_sort | Propuesta diseño de tratamiento de aguas residuales generadas en la unidad de diálisis del hospital Quito n°1 – Policía Nacional del Ecuador. |
| topic | UNIDAD DE DIÁLISIS LÍMITES MÁXIMOS PERMISIBLES LÍNEA DE TRATAMIENTO MEDIO AMBIENTE |
| url | http://repositorio.utc.edu.ec/handle/27000/11038 |