Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1

In this research a differential relay prototype was built, which it was implemented in the Electrical Engineering laboratory together with a bank of three-phase transformers and a resistive load module, whose objective is to analyze the operating pending of this relay and develop laboratory teaching...

Description complète

Enregistré dans:
Détails bibliographiques
Auteur principal: Caiza Jami, Robinson Israel (author)
Autres auteurs: Ramos Araujo, Mauricio Xavier (author)
Format: bachelorThesis
Langue:spa
Publié: 2019
Sujets:
Accès en ligne:http://repositorio.utc.edu.ec/handle/27000/5584
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1822282028568018944
author Caiza Jami, Robinson Israel
author2 Ramos Araujo, Mauricio Xavier
author2_role author
author_facet Caiza Jami, Robinson Israel
Ramos Araujo, Mauricio Xavier
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Proaño Maldonado, Xavier Alfonso, Ing.
dc.creator.none.fl_str_mv Caiza Jami, Robinson Israel
Ramos Araujo, Mauricio Xavier
dc.date.none.fl_str_mv 2019
2020-07-29T21:55:49Z
2020-07-29T21:55:49Z
dc.format.none.fl_str_mv 147 páginas
dc.identifier.none.fl_str_mv Caiza Jami Robinson Israel Ramos Araujo Mauricio Xavier (2019); Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1. UTC. Latacunga. 147 p.
PI-001114
http://repositorio.utc.edu.ec/handle/27000/5584
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv PENDIENTE
OPERACIÓN
RÉGIMEN PERMANENTE
TRANSFORMADORES
SISTEMAS ELÉCTRICOS
dc.title.none.fl_str_mv Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description In this research a differential relay prototype was built, which it was implemented in the Electrical Engineering laboratory together with a bank of three-phase transformers and a resistive load module, whose objective is to analyze the operating pending of this relay and develop laboratory teaching practices , familiarizing students with the calibration parameters of the same. In the bank of three-phase transformers, it did the Dy1 configuration is made to feed a module of resistive balanced loads, and to obtain the currents between the primary and secondary windings of the transformer. These currents are recorded through the differential relay module that sends a signal to the protection relay, provided that the operating current I_op exceeds the minimum operating current I_dopmin, the relay acts by disconnecting the power supply system and displaying the slope graphs of the slope of each phases with their respective current values and records the time at the time the fault occurred. Finally, it developed laboratory practices where students can interact with the differential relay module by entering the operation parameters such as the pending, start current, upper limit of the graph, correction and staging factors. At the end, it did user manual and laboratory practice guides.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_7bf594773e3ee04faf5c3dd79f6bdddc
identifier_str_mv Caiza Jami Robinson Israel Ramos Araujo Mauricio Xavier (2019); Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1. UTC. Latacunga. 147 p.
PI-001114
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/5584
publishDate 2019
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1Caiza Jami, Robinson IsraelRamos Araujo, Mauricio XavierPENDIENTEOPERACIÓNRÉGIMEN PERMANENTETRANSFORMADORESSISTEMAS ELÉCTRICOSIn this research a differential relay prototype was built, which it was implemented in the Electrical Engineering laboratory together with a bank of three-phase transformers and a resistive load module, whose objective is to analyze the operating pending of this relay and develop laboratory teaching practices , familiarizing students with the calibration parameters of the same. In the bank of three-phase transformers, it did the Dy1 configuration is made to feed a module of resistive balanced loads, and to obtain the currents between the primary and secondary windings of the transformer. These currents are recorded through the differential relay module that sends a signal to the protection relay, provided that the operating current I_op exceeds the minimum operating current I_dopmin, the relay acts by disconnecting the power supply system and displaying the slope graphs of the slope of each phases with their respective current values and records the time at the time the fault occurred. Finally, it developed laboratory practices where students can interact with the differential relay module by entering the operation parameters such as the pending, start current, upper limit of the graph, correction and staging factors. At the end, it did user manual and laboratory practice guides.En el presente proyecto se construyó un prototipo de relé diferencial que fue implementado en el laboratorio de Ingeniería Eléctrica junto a banco de transformadores trifásicos y un módulo de cargas resistivas, cuyo objetivo es analizar la pendiente de operación de este relé y desarrollar practicas didácticas de laboratorio, familiarizando a los estudiantes con los parámetros de calibración del mismo. En el banco de transformadores trifásicos se realiza la configuración Dy1 para alimentar un módulo de cargas balanceadas resistivas, y poder obtener las corrientes entre los devanados primarios y secundarios del transformador. Estas corrientes son censadas atreves del módulo del relé diferencial que envía una señal al relé de protección, siempre que la corriente de operación supere a la corriente diferencial de operación mínima , el relé actúa desconectando el sistema de alimentación y mostrando las gráficas de las pendientes de cada uno de las fases con sus respectivos valores de corrientes y registra el tiempo en el instante que ocurrió la falla. Finalmente se elaboró prácticas de laboratorio donde los estudiantes pueden interactuar con el módulo de relé diferencial ingresando los parámetros de operación como son la pendiente, corriente de arranque, límite superior de la gráfica, los factores de corrección y escalonamiento. Al finalizar se elaboró un manual de usuario y guías de prácticas de laboratorio.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC).Proaño Maldonado, Xavier Alfonso, Ing.2020-07-29T21:55:49Z2020-07-29T21:55:49Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis147 páginasCaiza Jami Robinson Israel Ramos Araujo Mauricio Xavier (2019); Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1. UTC. Latacunga. 147 p.PI-001114http://repositorio.utc.edu.ec/handle/27000/5584spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2020-07-30T08:00:35Zoai:oai:repositorio.utc.edu.ec:27000:27000/5584Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:15.593784Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
Caiza Jami, Robinson Israel
PENDIENTE
OPERACIÓN
RÉGIMEN PERMANENTE
TRANSFORMADORES
SISTEMAS ELÉCTRICOS
status_str publishedVersion
title Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
title_full Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
title_fullStr Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
title_full_unstemmed Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
title_short Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
title_sort Análisis de la pendiente de operación del relé diferencial frente a fallas trifásicas en régimen permanente, aplicado a un banco de transformadores trifásicos Yd1
topic PENDIENTE
OPERACIÓN
RÉGIMEN PERMANENTE
TRANSFORMADORES
SISTEMAS ELÉCTRICOS
url http://repositorio.utc.edu.ec/handle/27000/5584