Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.

This research work deals with the reliability analysis in the feeders belonging to the Quevedo substation of CNEL EP, in order to establish the circuits with the highest number of electrical power interruptions to submit them to a reconfiguration analysis, using historical data from the last three y...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile nagusia: Grandes Zambrano, Johanna Lizette (author)
Beste egile batzuk: Lechon Carvajal, Edison José (author)
Formatua: bachelorThesis
Hizkuntza:spa
Argitaratua: 2021
Gaiak:
Sarrera elektronikoa:http://repositorio.utc.edu.ec/handle/27000/7849
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
_version_ 1822282043452555264
author Grandes Zambrano, Johanna Lizette
author2 Lechon Carvajal, Edison José
author2_role author
author_facet Grandes Zambrano, Johanna Lizette
Lechon Carvajal, Edison José
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Pesantez, Gabriel
dc.creator.none.fl_str_mv Grandes Zambrano, Johanna Lizette
Lechon Carvajal, Edison José
dc.date.none.fl_str_mv 2021-12-14T19:40:05Z
2021-12-14T19:40:05Z
2021-03
dc.format.none.fl_str_mv 83 páginas
dc.identifier.none.fl_str_mv Grandes Zambrano Johanna Lizette, Lechon Carvajal Edison José ( 2021); Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo. UTC. Latacunga. 83 p.
PI-001669
http://repositorio.utc.edu.ec/handle/27000/7849
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi; UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv CONFIABILIDAD EN DISTRIBUCIÓN
PROBABILIDAD
TASA DE REPARACIÓN
TASA DE FALLA
INGENIERÍA ELÉCTRICA
dc.title.none.fl_str_mv Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description This research work deals with the reliability analysis in the feeders belonging to the Quevedo substation of CNEL EP, in order to establish the circuits with the highest number of electrical power interruptions to submit them to a reconfiguration analysis, using historical data from the last three years, where Pareto analysis is used to determine the percentage of interruptions that most affect each feeder. As a starting point, the information is classified by type of failure and duration, to determine the rate of failure and repair, availability (A) and unavailability (U) of the feeders, data with which it is possible to calculate the failure rates. reliability. From these results, the reconfiguration of circuit 6 is analyzed, since it presents the lowest indices. Using the Monte Carlo simulation in the MATLAB software package, it will be possible to determine the failure times and repair times in each section of the feeder. Applying the theory of graphs, the section with failure (disconnected) and the possible reconnection from neighboring nodes are determined, considering as a restriction the chargeability of the lines, that the repair time is less than the maneuvering time for a possible reconnection. This will allow new reliability indices to be calculated before and after reconfiguration during a prudent analysis time, allowing the optimal path to be identified.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_8b02e1eec0166bd6f495161d8651d72f
identifier_str_mv Grandes Zambrano Johanna Lizette, Lechon Carvajal Edison José ( 2021); Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo. UTC. Latacunga. 83 p.
PI-001669
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/7849
publishDate 2021
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi; UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.Grandes Zambrano, Johanna LizetteLechon Carvajal, Edison JoséCONFIABILIDAD EN DISTRIBUCIÓNPROBABILIDADTASA DE REPARACIÓNTASA DE FALLAINGENIERÍA ELÉCTRICAThis research work deals with the reliability analysis in the feeders belonging to the Quevedo substation of CNEL EP, in order to establish the circuits with the highest number of electrical power interruptions to submit them to a reconfiguration analysis, using historical data from the last three years, where Pareto analysis is used to determine the percentage of interruptions that most affect each feeder. As a starting point, the information is classified by type of failure and duration, to determine the rate of failure and repair, availability (A) and unavailability (U) of the feeders, data with which it is possible to calculate the failure rates. reliability. From these results, the reconfiguration of circuit 6 is analyzed, since it presents the lowest indices. Using the Monte Carlo simulation in the MATLAB software package, it will be possible to determine the failure times and repair times in each section of the feeder. Applying the theory of graphs, the section with failure (disconnected) and the possible reconnection from neighboring nodes are determined, considering as a restriction the chargeability of the lines, that the repair time is less than the maneuvering time for a possible reconnection. This will allow new reliability indices to be calculated before and after reconfiguration during a prudent analysis time, allowing the optimal path to be identified.El presente trabajo de investigación trata sobre el análisis de confiabilidad en los alimentadores pertenecientes a la subestación Quevedo de CNEL EP, con el fin de establecer los circuitos con mayor número de interrupciones de energía eléctrica para someterlos a un análisis de reconfiguración, utilizando datos históricos de los tres últimos años, donde se utiliza el análisis de Pareto para determinar el porcentaje de interrupciones que más inciden en cada alimentador. Como punto de partida se clasifica la información por tipo de falla y duración, para determinar la tasa de falla y reparación, disponibilidad (A) e indisponibilidad (U) de los alimentadores, datos con los cuales es posible realizar el cálculo de los índices de confiabilidad. De estos resultados se analiza la reconfiguración del circuito 6, ya que presenta los índices más bajos. Mediante la simulación de Monte Carlo en el paquete informático de MATLAB, se podrá determinar los tiempos de falla y tiempos de reparación en cada tramo del alimentador. Aplicando la teoría de grafos se determina el tramo con falla (desconectado) y la posible reconexión desde los nodos vecinos, considerando como restricción la cargabilidad de las líneas, que el tiempo de reparación sea menor al tiempo de maniobra para una posible reconexión. Esto permitirá calcular nuevos índices de confiabilidad antes y después de la reconfiguración durante un tiempo prudente de análisis, permitiendo identificar la ruta óptima.Ecuador: Latacunga: Universidad Técnica de Cotopaxi; UTC.Pesantez, Gabriel2021-12-14T19:40:05Z2021-12-14T19:40:05Z2021-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis83 páginasGrandes Zambrano Johanna Lizette, Lechon Carvajal Edison José ( 2021); Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo. UTC. Latacunga. 83 p.PI-001669http://repositorio.utc.edu.ec/handle/27000/7849spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2021-12-15T08:00:21Zoai:oai:repositorio.utc.edu.ec:27000:27000/7849Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:56.861957Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
Grandes Zambrano, Johanna Lizette
CONFIABILIDAD EN DISTRIBUCIÓN
PROBABILIDAD
TASA DE REPARACIÓN
TASA DE FALLA
INGENIERÍA ELÉCTRICA
status_str publishedVersion
title Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
title_full Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
title_fullStr Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
title_full_unstemmed Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
title_short Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
title_sort Optimización de la confiabilidad mediante la reconfiguración de circuitos primarios en la subestación Quevedo de CNEL EP. Unidad de negocio Santo Domingo.
topic CONFIABILIDAD EN DISTRIBUCIÓN
PROBABILIDAD
TASA DE REPARACIÓN
TASA DE FALLA
INGENIERÍA ELÉCTRICA
url http://repositorio.utc.edu.ec/handle/27000/7849