Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”

The industrial electrical a system power quality is affected by the several linear and non-linear loads that there are within it, by causing disturbances, what affect to the machinery operation, the production and the economy. This project was performed the electrical system energy quality study fro...

Бүрэн тодорхойлолт

-д хадгалсан:
Номзүйн дэлгэрэнгүй
Үндсэн зохиолч: Gallo Pérez, Marco Danilo (author)
Бусад зохиолчид: Roto Tenesaca, Jhony German (author)
Формат: bachelorThesis
Хэл сонгох:spa
Хэвлэсэн: 2022
Нөхцлүүд:
Онлайн хандалт:http://repositorio.utc.edu.ec/handle/27000/9343
Шошгууд: Шошго нэмэх
Шошго байхгүй, Энэхүү баримтыг шошголох эхний хүн болох!
_version_ 1822282052941119488
author Gallo Pérez, Marco Danilo
author2 Roto Tenesaca, Jhony German
author2_role author
author_facet Gallo Pérez, Marco Danilo
Roto Tenesaca, Jhony German
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Cabrera Celi, Gabriela Cristina
dc.creator.none.fl_str_mv Gallo Pérez, Marco Danilo
Roto Tenesaca, Jhony German
dc.date.none.fl_str_mv 2022-03
2023-01-11T14:08:06Z
2023-01-11T14:08:06Z
dc.format.none.fl_str_mv 162 páginas
dc.identifier.none.fl_str_mv Gallo Pérez Marco Danilo, Roto Tenesaca Jhony German (2022); Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”. UTC. Latacunga. 161 p.
PI-002152
http://repositorio.utc.edu.ec/handle/27000/9343
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv PERTURBACIONES ELÉCTRICAS
FACTOR DE POTENCIA
ARMÓNICOS
, PUESTA A TIERRA
ELÉCTRICA
POTENCIA
dc.title.none.fl_str_mv Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description The industrial electrical a system power quality is affected by the several linear and non-linear loads that there are within it, by causing disturbances, what affect to the machinery operation, the production and the economy. This project was performed the electrical system energy quality study from "EMBUTIDOS LA MADRILEÑA" enterprise, which presents disturbances into low voltage system coupled to 125 kVA and 500 kVA transformers secondary, respectively, what feed the enterprise different areas. Through field research was collected data onto the installed load, conductors type, conductors distance, protections, among others. Through the FLUKE 435-II network analyzer was got the power electrical parameters, voltage, power factor, total percentage and individual harmonics, both voltage and current for power quality study. Subsequently, they were analyzed the got electrical disturbances and compared with the set limits by the IEEE 519, IEEE 1159, ARCERNNR 002/20 and ARCONEL 035/19 regulations. With the got data were performed the simulation into ETAP 19.0.1 software, thus, determining the electrical problems to be corrected. Finally, it was proposed new conductors dimensioning solutions to reduce losses and voltage drop, the passive filter design for mitigating harmonics and raise the power factor, an improvement into grounding system, and was proposed a solution loads transfer from 125 kVA to 500 kVA transformer.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_977149de7a1ef294decd5d5a3cee0594
identifier_str_mv Gallo Pérez Marco Danilo, Roto Tenesaca Jhony German (2022); Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”. UTC. Latacunga. 161 p.
PI-002152
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/9343
publishDate 2022
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”Gallo Pérez, Marco DaniloRoto Tenesaca, Jhony GermanPERTURBACIONES ELÉCTRICASFACTOR DE POTENCIAARMÓNICOS, PUESTA A TIERRAELÉCTRICAPOTENCIAThe industrial electrical a system power quality is affected by the several linear and non-linear loads that there are within it, by causing disturbances, what affect to the machinery operation, the production and the economy. This project was performed the electrical system energy quality study from "EMBUTIDOS LA MADRILEÑA" enterprise, which presents disturbances into low voltage system coupled to 125 kVA and 500 kVA transformers secondary, respectively, what feed the enterprise different areas. Through field research was collected data onto the installed load, conductors type, conductors distance, protections, among others. Through the FLUKE 435-II network analyzer was got the power electrical parameters, voltage, power factor, total percentage and individual harmonics, both voltage and current for power quality study. Subsequently, they were analyzed the got electrical disturbances and compared with the set limits by the IEEE 519, IEEE 1159, ARCERNNR 002/20 and ARCONEL 035/19 regulations. With the got data were performed the simulation into ETAP 19.0.1 software, thus, determining the electrical problems to be corrected. Finally, it was proposed new conductors dimensioning solutions to reduce losses and voltage drop, the passive filter design for mitigating harmonics and raise the power factor, an improvement into grounding system, and was proposed a solution loads transfer from 125 kVA to 500 kVA transformer.La calidad de energía de un sistema eléctrico industrial se ve afectado por las diversas cargas lineales y no lineales existentes dentro del mismo, provocando perturbaciones que afectan el funcionamiento de las maquinarias, la producción y la economía. En este proyecto se realiza el estudio de calidad de energía del sistema eléctrico de la empresa “EMBUTIDOS LA MADRILEÑA” que presenta perturbaciones en el sistema de bajo voltaje acoplado al secundario de los transformadores de 125 kVA y 500 kVA respectivamente, que alimentan las diferentes áreas de la empresa. Mediante la investigación de campo se recolectó los datos de la carga instalada, tipo de conductores, distancia de conductores, protecciones, entre otros. Por medio del analizador de redes FLUKE 435-II se obtuvieron los parámetros eléctricos de potencia, voltaje, factor de potencia, porcentaje de armónicos totales e individuales tanto para voltaje y corriente para el estudio de calidad de energía. Posteriormente se analizó las perturbaciones eléctricas obtenidas, se comparó con los límites establecidos por las normativas: IEEE 519, IEEE 1159, ARCERNNR 002/20 y ARCONEL 035/19. Con los datos obtenidos se realizó la simulación en el software ETAP 19.0.1, determinando así los problemas eléctricos a ser corregidos. Finalmente se planteó soluciones de dimensionamiento de nuevos conductores para reducir las pérdidas y caída de voltaje, el diseño de un filtro pasivo para mitigar los armónicos y elevar el factor de potencia, un mejoramiento en el sistema de puesta a tierra, además se propuso una solución de traslado de cargas del transformador de 125 kVA al 500 kVA.Ecuador: Latacunga: Universidad Técnica de Cotopaxi (UTC)Cabrera Celi, Gabriela Cristina2023-01-11T14:08:06Z2023-01-11T14:08:06Z2022-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis162 páginasGallo Pérez Marco Danilo, Roto Tenesaca Jhony German (2022); Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”. UTC. Latacunga. 161 p.PI-002152http://repositorio.utc.edu.ec/handle/27000/9343spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2023-01-12T08:00:34Zoai:oai:repositorio.utc.edu.ec:27000:27000/9343Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:45:25.322805Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
Gallo Pérez, Marco Danilo
PERTURBACIONES ELÉCTRICAS
FACTOR DE POTENCIA
ARMÓNICOS
, PUESTA A TIERRA
ELÉCTRICA
POTENCIA
status_str publishedVersion
title Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
title_full Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
title_fullStr Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
title_full_unstemmed Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
title_short Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
title_sort Estudio de la calidad de energía del sistema eléctrico de la empresa “Embutidos la Madrileña”
topic PERTURBACIONES ELÉCTRICAS
FACTOR DE POTENCIA
ARMÓNICOS
, PUESTA A TIERRA
ELÉCTRICA
POTENCIA
url http://repositorio.utc.edu.ec/handle/27000/9343