Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.

The Subtransmission power lines are routes that connect distribution substations. In Ecuador there are several kilometers of these routes, operated by 20 electricity companies and the vast majority are radial systems, which due to a failure can disable distribution substations, which can leave sever...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
מחבר ראשי: Cruz Loya, Edwin Vinicio (author)
מחברים אחרים: Yugcha Quinatoa, Victor Hugo (author)
פורמט: masterThesis
שפה:spa
יצא לאור: 2021
נושאים:
גישה מקוונת:http://repositorio.utc.edu.ec/handle/27000/8013
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1822282044278833152
author Cruz Loya, Edwin Vinicio
author2 Yugcha Quinatoa, Victor Hugo
author2_role author
author_facet Cruz Loya, Edwin Vinicio
Yugcha Quinatoa, Victor Hugo
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv González, Iliana
dc.creator.none.fl_str_mv Cruz Loya, Edwin Vinicio
Yugcha Quinatoa, Victor Hugo
dc.date.none.fl_str_mv 2021-09
2022-01-18T21:24:41Z
2022-01-18T21:24:41Z
dc.format.none.fl_str_mv 127 páginas
dc.identifier.none.fl_str_mv Cruz Loya Edwin Vinicio, Yugcha Quinatoa Victor Hugo (2021), Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador. UTC. Latacunga. 127 p.
MUTC-001016
http://repositorio.utc.edu.ec/handle/27000/8013
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv LÍNEAS DE SUBTRANSMISIÓN
MANTENIMIENTO PREDICTIVO
MANTENIBILIDAD
INSPECCIÓN VISUAL
ELECTRICIDAD
dc.title.none.fl_str_mv Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
description The Subtransmission power lines are routes that connect distribution substations. In Ecuador there are several kilometers of these routes, operated by 20 electricity companies and the vast majority are radial systems, which due to a failure can disable distribution substations, which can leave several users without service, affecting power supply. distributor in the service quality indexes. It is important to mention that most of these lines are older than 25 years of construction, which makes them more susceptible to failure of mechanical and electrical elements, which are prone to corrosion and degradation; due to climatic factors, end of useful life, mechanical and electrical stresses, affectation by flora and fauna, etc. A failure can leave a large number of customers without electricity service, causing them great economic losses that will never be recovered and preventing commercial and industrial development, at the same time, penalties and fines are generated for distribution companies, existing both for the customer and for the supplier irrecoverable losses.- Therefore, due to the fact that it is very expensive to make ringed systems, and at the moment there is no solution to the case; And since there are no rules and procedures for predictive maintenance in electrical sub-transmission systems, predictive maintenance processes that support the maintainability of sub-transmission lines will be analyzed with visual inspection techniques, infrared thermography, corona effect and acoustic ultrasound, with drones. and on foot, to find possible anomalies and avoid unscheduled disconnections of the subtransmission lines in Ecuador.
eu_rights_str_mv openAccess
format masterThesis
id UTC_a6819a5ed0155df3ef24dab481a161db
identifier_str_mv Cruz Loya Edwin Vinicio, Yugcha Quinatoa Victor Hugo (2021), Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador. UTC. Latacunga. 127 p.
MUTC-001016
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/8013
publishDate 2021
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.Cruz Loya, Edwin VinicioYugcha Quinatoa, Victor HugoLÍNEAS DE SUBTRANSMISIÓNMANTENIMIENTO PREDICTIVOMANTENIBILIDADINSPECCIÓN VISUALELECTRICIDADThe Subtransmission power lines are routes that connect distribution substations. In Ecuador there are several kilometers of these routes, operated by 20 electricity companies and the vast majority are radial systems, which due to a failure can disable distribution substations, which can leave several users without service, affecting power supply. distributor in the service quality indexes. It is important to mention that most of these lines are older than 25 years of construction, which makes them more susceptible to failure of mechanical and electrical elements, which are prone to corrosion and degradation; due to climatic factors, end of useful life, mechanical and electrical stresses, affectation by flora and fauna, etc. A failure can leave a large number of customers without electricity service, causing them great economic losses that will never be recovered and preventing commercial and industrial development, at the same time, penalties and fines are generated for distribution companies, existing both for the customer and for the supplier irrecoverable losses.- Therefore, due to the fact that it is very expensive to make ringed systems, and at the moment there is no solution to the case; And since there are no rules and procedures for predictive maintenance in electrical sub-transmission systems, predictive maintenance processes that support the maintainability of sub-transmission lines will be analyzed with visual inspection techniques, infrared thermography, corona effect and acoustic ultrasound, with drones. and on foot, to find possible anomalies and avoid unscheduled disconnections of the subtransmission lines in Ecuador.Las líneas eléctricas de subtrasmisión son recorridos que unen las subestaciones de distribución. En el Ecuador existe varios kilómetros de estos recorridos, operados por 20 empresas eléctricas y en su gran mayoría son sistemas radiales, lo cual al tener una falla puede inhabilitar las subestaciones de distribución, las cuales pueden dejar sin servicio a varios usuarios, afectando a la distribuidora en los índices de calidad del servicio. Es importante mencionar que la mayoría de éstas líneas tienen una construcción superior a los 25 años, lo cual hace que sea más susceptible a fallas de los elementos mecánicos y eléctricos, que son propensos a corrosión y degradación; por factores climáticos, culminación de vida útil, esfuerzos mecánicos y eléctricos, afectación por flora y fauna, etc. Una falla puede dejar sin servicio eléctrico a una gran cantidad de clientes provocándoles grandes pérdidas económicas que nunca serán recuperadas e impidiendo el desarrollo comercial e industrial, al mismo tiempo se genera sanciones y multas a las empresas distribuidoras, existiendo tanto para el cliente como para el proveedor pérdidas irrecuperables.- Por lo tanto, debido a que resulta muy costoso realizar sistemas anillados, y por el momento no se tiene una solución al caso; y al no existir normas y procedimientos de mantenimiento predictivo en sistemas eléctricos de subtransmisión, se analizará procesos de mantenimiento predictivo que apoyen a la mantenibilidad de las líneas de subtransmisión con las técnicas de inspección visual, termografía infrarroja, efecto corona y ultrasonido acústico, con drones y a pie, para encontrar las posibles anomalías y evitar las desconexiones no programada de las líneas de subtransmisión en el Ecuador.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.González, Iliana2022-01-18T21:24:41Z2022-01-18T21:24:41Z2021-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis127 páginasCruz Loya Edwin Vinicio, Yugcha Quinatoa Victor Hugo (2021), Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador. UTC. Latacunga. 127 p.MUTC-001016http://repositorio.utc.edu.ec/handle/27000/8013spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2022-01-19T08:00:41Zoai:oai:repositorio.utc.edu.ec:27000:27000/8013Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:59.776303Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
Cruz Loya, Edwin Vinicio
LÍNEAS DE SUBTRANSMISIÓN
MANTENIMIENTO PREDICTIVO
MANTENIBILIDAD
INSPECCIÓN VISUAL
ELECTRICIDAD
status_str publishedVersion
title Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
title_full Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
title_fullStr Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
title_full_unstemmed Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
title_short Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
title_sort Mantenimiento predictivo aplicando técnicas: visuales, termográficas, efecto corona y ultrasonido acústico para detectar anomalías y prever interrupciones de energía eléctrica, no programadas, de las líneas de subtransmisión en el Ecuador.
topic LÍNEAS DE SUBTRANSMISIÓN
MANTENIMIENTO PREDICTIVO
MANTENIBILIDAD
INSPECCIÓN VISUAL
ELECTRICIDAD
url http://repositorio.utc.edu.ec/handle/27000/8013