Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.

Every electric power distribution company that has medium voltage underground networks is exposed to a failure in any part of it, which is why implementing new technologies with their respective procedures is essential to ensure its reliability and quality of service. In this project, the procedures...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autor principal: Chancusig Chiliguano, Kevin Giovanny (author)
Format: bachelorThesis
Idioma:spa
Publicat: 2021
Matèries:
Accés en línia:http://repositorio.utc.edu.ec/handle/27000/7959
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
_version_ 1822282044122595328
author Chancusig Chiliguano, Kevin Giovanny
author_facet Chancusig Chiliguano, Kevin Giovanny
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Proaño, Xavier
dc.creator.none.fl_str_mv Chancusig Chiliguano, Kevin Giovanny
dc.date.none.fl_str_mv 2021-08
2022-01-12T16:31:30Z
2022-01-12T16:31:30Z
dc.format.none.fl_str_mv 118 páginas
dc.identifier.none.fl_str_mv Chancusig Chiliguano Kevin Giovanny (2021), Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito. UTC. Latacunga. 118 p.
PI-001733
http://repositorio.utc.edu.ec/handle/27000/7959
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv TDR
LOCALIZACIÓN PRECISO ACÚSTICA
CABLES ELÉCTRICOS SUBTERRÁNEOS
INGENIERÍA ELÉCTRICA
dc.title.none.fl_str_mv Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description Every electric power distribution company that has medium voltage underground networks is exposed to a failure in any part of it, which is why implementing new technologies with their respective procedures is essential to ensure its reliability and quality of service. In this project, the procedures to be followed for the location of faults in medium voltage subway electrical cables using Megger Centrix 2.0 system equipment were elaborated. First of all, a bibliographic compilation of all the aspects involved in the search for a fault in medium voltage underground distribution networks was carried out. Then, in order to validate the methods used to guide the system, a field test was performed in a distribution network belonging to Empresa Eléctrica Quito (EEQ) and it was proposed to perform simulations based on standards such as IEEE Std 1234-2019, using PSCAD software for TDR analysis (reflectometry in the time domain), while Matlab - Simulink software was used for precise acoustic location, implementing its characteristic circuits. Finally as results were obtained percentages of error between the field measurement and the high simulation but in spite of this it was possible to demonstrate that the principle of operation of the equipment used are present in the simulations performed, everything mentioned above is summarized in the data tables that contain each of the tests at the end of the simulated methods.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_a6889f494c300da0bbd293fde6f2e873
identifier_str_mv Chancusig Chiliguano Kevin Giovanny (2021), Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito. UTC. Latacunga. 118 p.
PI-001733
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/7959
publishDate 2021
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.Chancusig Chiliguano, Kevin GiovannyTDRLOCALIZACIÓN PRECISO ACÚSTICACABLES ELÉCTRICOS SUBTERRÁNEOSINGENIERÍA ELÉCTRICAEvery electric power distribution company that has medium voltage underground networks is exposed to a failure in any part of it, which is why implementing new technologies with their respective procedures is essential to ensure its reliability and quality of service. In this project, the procedures to be followed for the location of faults in medium voltage subway electrical cables using Megger Centrix 2.0 system equipment were elaborated. First of all, a bibliographic compilation of all the aspects involved in the search for a fault in medium voltage underground distribution networks was carried out. Then, in order to validate the methods used to guide the system, a field test was performed in a distribution network belonging to Empresa Eléctrica Quito (EEQ) and it was proposed to perform simulations based on standards such as IEEE Std 1234-2019, using PSCAD software for TDR analysis (reflectometry in the time domain), while Matlab - Simulink software was used for precise acoustic location, implementing its characteristic circuits. Finally as results were obtained percentages of error between the field measurement and the high simulation but in spite of this it was possible to demonstrate that the principle of operation of the equipment used are present in the simulations performed, everything mentioned above is summarized in the data tables that contain each of the tests at the end of the simulated methods.Toda empresa de distribución de energía eléctrica que cuenta con redes soterradas de media tensión está expuesta a una falla en cualquier parte de la misma, es por ello que el implementar nuevas tecnologías con sus respectivos procedimientos es fundamental para asegurar su confiabilidad y su calidad de servicio. En este proyecto se elaboró los procedimientos que se deben seguir para la localización de fallas en cables eléctricos subterráneos de media tensión aplicando equipos del sistema Megger Centrix 2.0. En primer lugar se realizó la recopilación bibliográfica de todos los aspectos que intervienen en la búsqueda de una falla en las redes de distribución soterradas de media tensión. A continuación con el fin de poder validar los métodos con los cuales se guía el sistema se ha realizado una prueba en campo en una red de distribución perteneciente a la Empresa Eléctrica Quito (EEQ) y se ha propuesto realizar simulaciones basándose en normativas como la IEEE Std 1234-2019, utilizando el software PSCAD para el análisis del TDR (reflectometría en el dominio del tiempo), mientras que para la localización preciso acústica se utilizó el software Matlab – Simulink implementando sus circuitos característicos. Finalmente como resultados se obtuvieron porcentajes de error entre la medida en campo y la simulación elevados pero que a pesar de ello se pudo demostrar que el principio de funcionamiento de los equipos utilizados están presentes en las simulaciones realizadas, todo lo mencionado anteriormente se resume en las tablas de datos que contienen cada una de las pruebas al final de los métodos simulados.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.Proaño, Xavier2022-01-12T16:31:30Z2022-01-12T16:31:30Z2021-08info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis118 páginasChancusig Chiliguano Kevin Giovanny (2021), Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito. UTC. Latacunga. 118 p.PI-001733http://repositorio.utc.edu.ec/handle/27000/7959spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2022-01-13T08:00:21Zoai:oai:repositorio.utc.edu.ec:27000:27000/7959Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:44:58.973474Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
Chancusig Chiliguano, Kevin Giovanny
TDR
LOCALIZACIÓN PRECISO ACÚSTICA
CABLES ELÉCTRICOS SUBTERRÁNEOS
INGENIERÍA ELÉCTRICA
status_str publishedVersion
title Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
title_full Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
title_fullStr Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
title_full_unstemmed Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
title_short Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
title_sort Determinación de procedimientos para la localización de fallas en redes eléctricas soterradas de medio voltaje utilizando el sistema Megger Centrix 2.0 de la Empresa Eléctrica Quito.
topic TDR
LOCALIZACIÓN PRECISO ACÚSTICA
CABLES ELÉCTRICOS SUBTERRÁNEOS
INGENIERÍA ELÉCTRICA
url http://repositorio.utc.edu.ec/handle/27000/7959