Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.

In the workshops of the Technical University of Cotopaxi, in the material strength laboratory, there is a TINIUS OLSEN universal testing machine that is powered by 220V triphasic that performs tests on different materials. This equipment came to have a serious damage in the control card of the machi...

Descrición completa

Gardado en:
Detalles Bibliográficos
Autor Principal: Tapia Alvarado, Cristopher Daniel (author)
Formato: bachelorThesis
Idioma:spa
Publicado: 2021
Subjects:
Acceso en liña:http://repositorio.utc.edu.ec/handle/27000/8085
Tags: Engadir etiqueta
Sen Etiquetas, Sexa o primeiro en etiquetar este rexistro!
_version_ 1822282044785295360
author Tapia Alvarado, Cristopher Daniel
author_facet Tapia Alvarado, Cristopher Daniel
author_role author
collection Repositorio Universidad Técnica de Cotopaxi
dc.contributor.none.fl_str_mv Cruz, Luis
dc.creator.none.fl_str_mv Tapia Alvarado, Cristopher Daniel
dc.date.none.fl_str_mv 2021-03
2022-01-25T16:53:10Z
2022-01-25T16:53:10Z
dc.format.none.fl_str_mv 101 páginas
dc.identifier.none.fl_str_mv Tapia Alvarado Cristopher Daniel (2021), Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi. UTC. Latacunga. 101 p.
PI-001813
http://repositorio.utc.edu.ec/handle/27000/8085
dc.language.none.fl_str_mv spa
dc.publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositorio Universidad Técnica de Cotopaxi
instname:Universidad Técnica de Cotopaxi
instacron:UTC
dc.subject.none.fl_str_mv CALIDAD DE ENERGÍA
ACOMETIDA
DESBALANCE
CAÍDA DE TENSIÓN
ELECTROMECÁNICA
dc.title.none.fl_str_mv Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/bachelorThesis
description In the workshops of the Technical University of Cotopaxi, in the material strength laboratory, there is a TINIUS OLSEN universal testing machine that is powered by 220V triphasic that performs tests on different materials. This equipment came to have a serious damage in the control card of the machine system that caused its failure, this event was caused by not having an individual connection for its proper electrical supply, from this fact the measurement was taken into consideration and the analysis of the energy quality in the place where the equipment was energized, the objective was possible to fulfill since the University provided the measuring equipment called Fluke 435 energy analyzer, this has the capacity to measure any type of event that exists in an electrical network, for this reason it was installed in a hydropneumatic laboratory in the distribution sub-panel (TDS5) with the aim of being able to determine the voltage quality, this analysis was governed based on the technical requirements recommended by the manufacturer and IEEE1159, EN50160 standards and ARCONEL regulations. Thanks to these data, the voltage quality and events that could cause damage to it were evaluated, taking into account that the ARCONEL regulation has a minimum measurement time of 7 days in 10-minute intervals, for this reason it was considered to measure those of events that occur at that time, thanks to the POWER LOG 430-II software, the data could be extracted and the results were expressed through Excel, justifying in curves and percentages. The results are found in methodology, the design of a new connection was carried out considering the technical requirements, calculations and the norms that delimit the voltage ranges and dimensioning of the elements for the connection. It was considered to measure the new connection with the energy analyzer and as a result the voltage variation was improved without variations greater than 8% and with an average improvement in phase A of 1.38%, phase B of 2.79% and phase C0.93%. The voltage unbalance also improved since no measurement exceeded 1.5% unbalance and an improvement of 1.15% was obtained. These data are expressed within the analysis of results and are governed by the manufacturer's requirements, limits established by the norms and regulations already mentioned, this project was carried out successfully since the machine meets the connection, voltage ranges and adequate protections for the system.
eu_rights_str_mv openAccess
format bachelorThesis
id UTC_a88ed022d8c73a73d33fecb02538e14c
identifier_str_mv Tapia Alvarado Cristopher Daniel (2021), Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi. UTC. Latacunga. 101 p.
PI-001813
instacron_str UTC
institution UTC
instname_str Universidad Técnica de Cotopaxi
language spa
network_acronym_str UTC
network_name_str Repositorio Universidad Técnica de Cotopaxi
oai_identifier_str oai:oai:repositorio.utc.edu.ec:27000:27000/8085
publishDate 2021
publisher.none.fl_str_mv Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.
reponame_str Repositorio Universidad Técnica de Cotopaxi
repository.mail.fl_str_mv .
repository.name.fl_str_mv Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxi
repository_id_str 0
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
spelling Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.Tapia Alvarado, Cristopher DanielCALIDAD DE ENERGÍAACOMETIDADESBALANCECAÍDA DE TENSIÓNELECTROMECÁNICAIn the workshops of the Technical University of Cotopaxi, in the material strength laboratory, there is a TINIUS OLSEN universal testing machine that is powered by 220V triphasic that performs tests on different materials. This equipment came to have a serious damage in the control card of the machine system that caused its failure, this event was caused by not having an individual connection for its proper electrical supply, from this fact the measurement was taken into consideration and the analysis of the energy quality in the place where the equipment was energized, the objective was possible to fulfill since the University provided the measuring equipment called Fluke 435 energy analyzer, this has the capacity to measure any type of event that exists in an electrical network, for this reason it was installed in a hydropneumatic laboratory in the distribution sub-panel (TDS5) with the aim of being able to determine the voltage quality, this analysis was governed based on the technical requirements recommended by the manufacturer and IEEE1159, EN50160 standards and ARCONEL regulations. Thanks to these data, the voltage quality and events that could cause damage to it were evaluated, taking into account that the ARCONEL regulation has a minimum measurement time of 7 days in 10-minute intervals, for this reason it was considered to measure those of events that occur at that time, thanks to the POWER LOG 430-II software, the data could be extracted and the results were expressed through Excel, justifying in curves and percentages. The results are found in methodology, the design of a new connection was carried out considering the technical requirements, calculations and the norms that delimit the voltage ranges and dimensioning of the elements for the connection. It was considered to measure the new connection with the energy analyzer and as a result the voltage variation was improved without variations greater than 8% and with an average improvement in phase A of 1.38%, phase B of 2.79% and phase C0.93%. The voltage unbalance also improved since no measurement exceeded 1.5% unbalance and an improvement of 1.15% was obtained. These data are expressed within the analysis of results and are governed by the manufacturer's requirements, limits established by the norms and regulations already mentioned, this project was carried out successfully since the machine meets the connection, voltage ranges and adequate protections for the system.En los talleres de la Universidad Técnica de Cotopaxi en el laboratorio de resistencia de materiales existe una máquina de pruebas universales TINIUS OLSEN que es alimentada a 220V trifásico que realiza pruebas de ensayos de diferentes materiales. Este equipo llegó a tener un daño grave en la tarjeta de control del sistema de la máquina que causó su avería, este suceso se ocasionó por no tener una acometida individual para su debida alimentación eléctrica, a partir de este hecho se tomó en consideración la medición y el análisis de la calidad energía en el lugar donde el equipo se encontraba energizado, el objetivo fue posible cumplirlo ya que la Universidad facilitó el equipo de medición denominado analizador de energía Fluke 435, este tiene la capacidad de medir cualquier tipo de suceso que exista en una red eléctrica, por tal motivo se llegó a instalar en laboratorio de hidroneumática en el subtablero de distribución (TDS5) con el afán de poder determinar la calidad de voltaje, este análisis se rigió en base a los requerimientos técnicos que recomienda el fabricante y las normas IEEE1159, EN50160 y las regulaciones del ARCONEL. Gracias a estos datos se evaluó la calidad de tensión y eventos que pudieron ocasionar el daño a la misma, tomando en cuenta que la regulación del ARCONELtiene denominado como tiempo mínimo de la medición 7 días en intervalos de 10 minutos, por este motivo se consideró medir los de eventos que se producen en ese tiempo, gracias al software POWER LOG 430-II se pudo extraer los datos y se expresó los resultados por medio de Excel justificando en curvas y porcentajes. Los resultados se encuentran en metodología, se realizó el diseño de una nueva acometida considerando los requerimientos técnicos, cálculos y las normas que delimitan los rangos de voltaje y dimensionamiento de los elementos para la acometida. Se consideró medir la nueva acometida con el analizador de energía y como resultados se mejoró la variación de voltaje sin que existan variaciones mayores al 8% y con una mejora promedio en la fase A de 1.38%, fase B de 2,79% y fase C 0,93%. También de mejoro el desbalance de tensión ya que ninguna medición superó el 1,5% de desbalance y obteniendo una mejora del 1.15%, estos datos están expresados dentro de los análisis de resultados y se rigen a los requerimientos del fabricante, límites que establece la normativas y regulaciones ya mencionadas, este proyecto fue realizado con éxito ya que la máquina se encuentra con la acometida, rangos de tensión y protecciones adecuadas al sistema.Ecuador: Latacunga: Universidad Técnica de Cotopaxi: UTC.Cruz, Luis2022-01-25T16:53:10Z2022-01-25T16:53:10Z2021-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis101 páginasTapia Alvarado Cristopher Daniel (2021), Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi. UTC. Latacunga. 101 p.PI-001813http://repositorio.utc.edu.ec/handle/27000/8085spahttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/info:eu-repo/semantics/openAccessreponame:Repositorio Universidad Técnica de Cotopaxiinstname:Universidad Técnica de Cotopaxiinstacron:UTC2022-01-26T08:00:33Zoai:oai:repositorio.utc.edu.ec:27000:27000/8085Institucionalhttp://repositorio.utc.edu.ec/Universidad públicahttps://www.utc.edu.ec/..Ecuador...opendoar:02025-01-26T03:45:01.072426Repositorio Universidad Técnica de Cotopaxi - Universidad Técnica de Cotopaxitrue
spellingShingle Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
Tapia Alvarado, Cristopher Daniel
CALIDAD DE ENERGÍA
ACOMETIDA
DESBALANCE
CAÍDA DE TENSIÓN
ELECTROMECÁNICA
status_str publishedVersion
title Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
title_full Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
title_fullStr Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
title_full_unstemmed Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
title_short Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
title_sort Diseño e implementación de una acometida para la máquina de prueba universal (TINIUS O OLSEN) del laboratorio de resistencia de materiales de la Universidad Técnica de Cotopaxi.
topic CALIDAD DE ENERGÍA
ACOMETIDA
DESBALANCE
CAÍDA DE TENSIÓN
ELECTROMECÁNICA
url http://repositorio.utc.edu.ec/handle/27000/8085